HP Client Manager 6.1
Page 3
...-side events, such as a chassis intrusion, disk drive error, battery status, thermal changes, and "walking assets" such as new or missing PCs, memory, battery, disk drives, CPUs, and monitors. For example, you can use HPCM to happen automatically and remotely across all client computers...8226; Client inventory: Includes detailed client information such as the chassis serial number, computer model number, memory size, operating system, CPU identification, and many more secure client infrastructure. Use the HP Client Manager console to remotely initialize the security chip on those ...
...-side events, such as a chassis intrusion, disk drive error, battery status, thermal changes, and "walking assets" such as new or missing PCs, memory, battery, disk drives, CPUs, and monitors. For example, you can use HPCM to happen automatically and remotely across all client computers...8226; Client inventory: Includes detailed client information such as the chassis serial number, computer model number, memory size, operating system, CPU identification, and many more secure client infrastructure. Use the HP Client Manager console to remotely initialize the security chip on those ...
HP Client Manager 6.1
Page 8
... your predefined notification policies. Figure 5. You can specify that an e-mail be sent to you to alert you to memory changes, disk drive changes, or CPU changes. For example, you can also monitor the status of these events using one of a theft. 8 The health monitoring capability of HPCM simplifies the task...
... your predefined notification policies. Figure 5. You can specify that an e-mail be sent to you to alert you to memory changes, disk drive changes, or CPU changes. For example, you can also monitor the status of these events using one of a theft. 8 The health monitoring capability of HPCM simplifies the task...
HP Client Manager 6.1
Page 9
Figure 6. Sample Diagnostics screen 9 The partial screen capture in this screen shot). Errors detected by the diagnostic software are performed on the memory, CPU, storage devices and I/O devices. Diagnostics Diagnostics are reported in the far right column (not shown in Figure 6 shows a typical diagnostics report.
Figure 6. Sample Diagnostics screen 9 The partial screen capture in this screen shot). Errors detected by the diagnostic software are performed on the memory, CPU, storage devices and I/O devices. Diagnostics Diagnostics are reported in the far right column (not shown in Figure 6 shows a typical diagnostics report.
Runtime Power Management v1.0
Page 2
... adjusts the operating frequency and voltage of a processor up to take advantage of the processor. For a system to 30 times per second depending on the CPU load. When full processor performance is also especially useful for several years. Why are EIST and Cool'n'Quiet needed , the processor slows its processor power...
... adjusts the operating frequency and voltage of a processor up to take advantage of the processor. For a system to 30 times per second depending on the CPU load. When full processor performance is also especially useful for several years. Why are EIST and Cool'n'Quiet needed , the processor slows its processor power...
Runtime Power Management v1.0
Page 3
...) Cool'n'Quiet requires the ATI RS480/SB400 (Radeon Xpress) chipset. The default EIST BIOS support setting depends on systems that allows CPU throttling to slow down the processor. EIST uses the operating system to control processor throttling. You can enable or disable the Runtime Power... chipsets include: Intel 915: • dc5100 • dc7100 • dx6100 (not available in North America) Intel 945: • dc7600 • dx7200 (not available in F10 Setup - EIST will replace TM2. Disabled RTPM Option Not Shown in F10 Setup Thermal Monitor 2 (TM2) is located in F10...
...) Cool'n'Quiet requires the ATI RS480/SB400 (Radeon Xpress) chipset. The default EIST BIOS support setting depends on systems that allows CPU throttling to slow down the processor. EIST uses the operating system to control processor throttling. You can enable or disable the Runtime Power... chipsets include: Intel 915: • dc5100 • dc7100 • dx6100 (not available in North America) Intel 945: • dc7600 • dx7200 (not available in F10 Setup - EIST will replace TM2. Disabled RTPM Option Not Shown in F10 Setup Thermal Monitor 2 (TM2) is located in F10...
Runtime Power Management v1.0
Page 4
...performance state. 4 The processor performance control policy is no RTPM capability for HP dx5150 systems is controlled by EIST and the operating system. CPU usage determines performance state. • Degrade - Operating System Microsoft implemented EIST support in the BIOS of a processor with the kernel power policy... if the processor is not Hyper-Threaded (HT). The default Cool'n'Quiet support for processors that support both EIST and TM2, CPU throttling is set to interact and control different processors - For processors that do not support EIST or TM2. Once the performance ...
...performance state. 4 The processor performance control policy is no RTPM capability for HP dx5150 systems is controlled by EIST and the operating system. CPU usage determines performance state. • Degrade - Operating System Microsoft implemented EIST support in the BIOS of a processor with the kernel power policy... if the processor is not Hyper-Threaded (HT). The default Cool'n'Quiet support for processors that support both EIST and TM2, CPU throttling is set to interact and control different processors - For processors that do not support EIST or TM2. Once the performance ...
HP Compaq Business PC dx7200 MT Illustrated Parts Map, 1st Edition
Page 2
...audio in Primary IDE Front audio Front panel USB Primary Serial ATA (SATA) Port connector Secondary Serial ATA (SATA) Port connector CPU fan Battery Memory socket Memory socket Memory socket Memory socket Microprocessor socket System Hardware Interrupts IRQ System Function 0 Timer Interrupt 1 ...RAM Power Clear Off (S4) Hibernation Mode Power Clear Off (S5) Computer off Power Red* 2 blinks 1 second apart CPU thermal shutdown Power Red* 3 blinks 1 second apart CPU not installed Power Red* 4 blinks 1 second apart Power supply overload (crow bar) Power Red* 5 blinks 1 second ...
...audio in Primary IDE Front audio Front panel USB Primary Serial ATA (SATA) Port connector Secondary Serial ATA (SATA) Port connector CPU fan Battery Memory socket Memory socket Memory socket Memory socket Microprocessor socket System Hardware Interrupts IRQ System Function 0 Timer Interrupt 1 ...RAM Power Clear Off (S4) Hibernation Mode Power Clear Off (S5) Computer off Power Red* 2 blinks 1 second apart CPU thermal shutdown Power Red* 3 blinks 1 second apart CPU not installed Power Red* 4 blinks 1 second apart Power supply overload (crow bar) Power Red* 5 blinks 1 second ...
HP Compaq Business PC dx7200 MT Service Reference Guide, 1st edition
Page 33
... revision levels of device drivers and BIOS updates for networked HP business PCs. Service Reference Guide, dx7200 390812-001 3-3 SSM then automatically updates any down-revision system software on the networked PCs to quickly resolve hardware problems HP Client Manager uses the same Altiris ..., visit www.hp.com/go /ssm. 3.3.2 HP Client Manager HP Client Manager, developed with enterprise software distribution tools such as CPU, memory, video, and security settings ■ Monitor system health to the correct client system models, administrators can distribute customer-created ...
... revision levels of device drivers and BIOS updates for networked HP business PCs. Service Reference Guide, dx7200 390812-001 3-3 SSM then automatically updates any down-revision system software on the networked PCs to quickly resolve hardware problems HP Client Manager uses the same Altiris ..., visit www.hp.com/go /ssm. 3.3.2 HP Client Manager HP Client Manager, developed with enterprise software distribution tools such as CPU, memory, video, and security settings ■ Monitor system health to the correct client system models, administrators can distribute customer-created ...
HP Compaq Business PC dx7200 MT Service Reference Guide, 1st edition
Page 70
...servicing this computer, ensure that was removed, then returned to failed drives as well as monitors or speakers. 5-8 390812-001 Service Reference Guide, dx7200 Improper cable placement can damage the unit. While handling a drive, avoid touching the connector. screws have magnetic fields such as replacement spares. ■...silver finish and are used on or in their protective packaging until they cannot be mailed, place the drive in the CPU. ■ Avoid dropping drives from the work area to liquids, temperature extremes, or products that you are not interchangeable.
...servicing this computer, ensure that was removed, then returned to failed drives as well as monitors or speakers. 5-8 390812-001 Service Reference Guide, dx7200 Improper cable placement can damage the unit. While handling a drive, avoid touching the connector. screws have magnetic fields such as replacement spares. ■...silver finish and are used on or in their protective packaging until they cannot be mailed, place the drive in the CPU. ■ Avoid dropping drives from the work area to liquids, temperature extremes, or products that you are not interchangeable.
HP Compaq Business PC dx7200 MT Service Reference Guide, 1st edition
Page 157
... 6 GND 12 Pin Signal 7 PWRGD 8 +3.3 V 9 +3.3 V 10 Tach 11 GND 12 Fan-CMD 4-Pin Power (for CPU) Connector and Icon 1 Pin Signal 13 +12 V 14 +5 V Sense 15 GND 16 +5 V 17 +5 V 18 +3.3 V Pin Signal 1 GND 2 GND 3 +12 V CPU 4 -12 V CPU Pin Signal 19 GND 20 +3.3 Sense 21 +3.3 V 22 +3.3 V 23 GND 24 -12 V Service Reference Guide...
... 6 GND 12 Pin Signal 7 PWRGD 8 +3.3 V 9 +3.3 V 10 Tach 11 GND 12 Fan-CMD 4-Pin Power (for CPU) Connector and Icon 1 Pin Signal 13 +12 V 14 +5 V Sense 15 GND 16 +5 V 17 +5 V 18 +3.3 V Pin Signal 1 GND 2 GND 3 +12 V CPU 4 -12 V CPU Pin Signal 19 GND 20 +3.3 Sense 21 +3.3 V 22 +3.3 V 23 GND 24 -12 V Service Reference Guide...
HP Compaq Business PC dx7200 MT Service Reference Guide, 1st edition
Page 158
S2 A+ S6 B+ P1 V 3.3 P5 Ground P9 V 5 P13 V 12 P2 V 3.3 P6 Ground P10 Ground P14 V 12 *S = Data, P = Power Pin Signal S3 AS7 Ground P3 V 3.3 P7 V 5 P11 Reserved P15 V 12 Pin Signal S4 Ground P4 Ground P8 V 5 P12 Ground A-8 390812-001 Service Reference Guide, dx7200 Connector Pin Assignments 6-Pin Power (for CPU) Connector and Icon 4 6 Pin Signal 1 GND 2 GND 3 GND 4 12 V CPU 5 12 V CPU 6 +12 V SATA Data and Power Drive Connector Pin Signal Pin Signal S1 Ground S5 B-
S2 A+ S6 B+ P1 V 3.3 P5 Ground P9 V 5 P13 V 12 P2 V 3.3 P6 Ground P10 Ground P14 V 12 *S = Data, P = Power Pin Signal S3 AS7 Ground P3 V 3.3 P7 V 5 P11 Reserved P15 V 12 Pin Signal S4 Ground P4 Ground P8 V 5 P12 Ground A-8 390812-001 Service Reference Guide, dx7200 Connector Pin Assignments 6-Pin Power (for CPU) Connector and Icon 4 6 Pin Signal 1 GND 2 GND 3 GND 4 12 V CPU 5 12 V CPU 6 +12 V SATA Data and Power Drive Connector Pin Signal Pin Signal S1 Ground S5 B-
HP Compaq Business PC dx7200 MT Service Reference Guide, 1st edition
Page 168
.... Reconfigure card resources and/or run Computer Setup. Reflash the system ROM with another device. C-4 390812-001 Service Reference Guide, dx7200 Remove any parallel port expansion cards. Enter Computer Setup and reset the IRQ in Advanced > Onboard Devices. Replace the fan. Reseat... CPU or chassis fan. Recommended Action Reconnect the keyboard with another device. Clear CMOS. Reseat fan cable. Replace system board. Reseat chassis,...
.... Reconfigure card resources and/or run Computer Setup. Reflash the system ROM with another device. C-4 390812-001 Service Reference Guide, dx7200 Remove any parallel port expansion cards. Enter Computer Setup and reset the IRQ in Advanced > Onboard Devices. Replace the fan. Reseat... CPU or chassis fan. Recommended Action Reconnect the keyboard with another device. Clear CMOS. Reseat fan cable. Replace system board. Reseat chassis,...
HP Compaq Business PC dx7200 MT Service Reference Guide, 1st edition
Page 172
Parity RAM failure. Open hood, press the power button, and see if the processor fan spins. C-8 390812-001 Service Reference Guide, dx7200 If not spinning, make sure the fan cable is properly installed and the fan connected but does not spin, replace the heatsink-fan assembly.... If the heatsink is plugged into the system board. CPU fan not installed or disconnected in VSFF chassis. Check connector for bent or missing pins. Replace keyboard. Ensure the heatsink is properly seated. POST...
Parity RAM failure. Open hood, press the power button, and see if the processor fan spins. C-8 390812-001 Service Reference Guide, dx7200 If not spinning, make sure the fan cable is properly installed and the fan connected but does not spin, replace the heatsink-fan assembly.... If the heatsink is plugged into the system board. CPU fan not installed or disconnected in VSFF chassis. Check connector for bent or missing pins. Replace keyboard. Ensure the heatsink is properly seated. POST...
HP Compaq Business PC dx7200 MT Service Reference Guide, 1st edition
Page 207
...Internal USB connector 1 Internal USB connector 2 MultiBay header SCSI LED connector PCI extender slot (female) Blade PC graphics connector (outboard) Blade PC graphics connector (inboard) Second serial port Primary serial port Double stack serial port, Top = Serial B,...ATA (SATA) connector Seventh Serial ATA (SATA) connector Eighth Serial ATA (SATA) connector Primary (CPU) fan header for fansink Secondary CPU fan header for fansink Primary Serial Attached SCSI (SAS) connector Second Serial Attached SCSI (SAS) ... North bridge South bridge Super I/O Service Reference Guide, dx7200 390812-001 E-3
...Internal USB connector 1 Internal USB connector 2 MultiBay header SCSI LED connector PCI extender slot (female) Blade PC graphics connector (outboard) Blade PC graphics connector (inboard) Second serial port Primary serial port Double stack serial port, Top = Serial B,...ATA (SATA) connector Seventh Serial ATA (SATA) connector Eighth Serial ATA (SATA) connector Primary (CPU) fan header for fansink Secondary CPU fan header for fansink Primary Serial Attached SCSI (SAS) connector Second Serial Attached SCSI (SAS) ... North bridge South bridge Super I/O Service Reference Guide, dx7200 390812-001 E-3