... Chapter 4 Battery Maintenance Precautions ...4-1 Charging Batteries...4-1 Determining When to Replace Batteries 4-2 Obtaining New Batteries ...4-2 Replacing the Batteries...4-2 Removing the Battery Pack ...4-3 Installing a New Battery Pack ...4-6 Testing the New Battery Pack ...4-6 Disposing of Used Batteries ...4-7 Care and Storage of Batteries...4-7 Pre-Failure Battery Warranty...4-8 Chapter 5 Troubleshooting Responding to Audible Alarms ...5-1 Trouble Indicators ...5-4 LED Alarm Configurations ...5-4 Repairing the UPS...5-5 iv HP Uninterruptible Power System R6000 Models...
... Chapter 4 Battery Maintenance Precautions ...4-1 Charging Batteries...4-1 Determining When to Replace Batteries 4-2 Obtaining New Batteries ...4-2 Replacing the Batteries...4-2 Removing the Battery Pack ...4-3 Installing a New Battery Pack ...4-6 Testing the New Battery Pack ...4-6 Disposing of Used Batteries ...4-7 Care and Storage of Batteries...4-7 Pre-Failure Battery Warranty...4-8 Chapter 5 Troubleshooting Responding to Audible Alarms ...5-1 Trouble Indicators ...5-4 LED Alarm Configurations ...5-4 Repairing the UPS...5-5 iv HP Uninterruptible Power System R6000 Models...
HP Uninterruptible Power System R6000 Models User Guide
Page 5
... Marked with the FCC Logo, United States Only A-2 Modifications ...A-2 Cables...A-3 Canadian Notice (Avis Canadien) ...A-3 Class A Equipment...A-3 Class B Equipment ...A-3 European Union Notice ...A-3 Japanese Notice ...A-4 BSMI Notice...A-4 Battery Replacement Notice ...A-5 Appendix B Electrostatic Discharge Preventing Electrostatic Damage...B-1 Grounding Methods To Prevent Electrostatic Damage B-1 Appendix C Specifications Physical Specifications ...C-1 Input Specifications ...C-1 Output Specifications...
... Marked with the FCC Logo, United States Only A-2 Modifications ...A-2 Cables...A-3 Canadian Notice (Avis Canadien) ...A-3 Class A Equipment...A-3 Class B Equipment ...A-3 European Union Notice ...A-3 Japanese Notice ...A-4 BSMI Notice...A-4 Battery Replacement Notice ...A-5 Appendix B Electrostatic Discharge Preventing Electrostatic Damage...B-1 Grounding Methods To Prevent Electrostatic Damage B-1 Appendix C Specifications Physical Specifications ...C-1 Input Specifications ...C-1 Output Specifications...
HP Uninterruptible Power System R6000 Models User Guide
Page 34
... more under voltage) and the UPS boosts the output voltage up. The batteries must be replaced. Main Menu → Active Alarms If there is on the utility voltage, the battery test has failed and the batteries must be recharged for the UPS when an alarm sounds and the LED ...the UPS is on battery power, the battery needs to view the active alarms for 24 hours before further use. There is lowa 60-day warning. Check the utility voltage connection. Decrease the number of the nominal range setting. continued HP Uninterruptible Power System R6000 Models User Guide ...
... more under voltage) and the UPS boosts the output voltage up. The batteries must be replaced. Main Menu → Active Alarms If there is on the utility voltage, the battery test has failed and the batteries must be recharged for the UPS when an alarm sounds and the LED ...the UPS is on battery power, the battery needs to view the active alarms for 24 hours before further use. There is lowa 60-day warning. Check the utility voltage connection. Decrease the number of the nominal range setting. continued HP Uninterruptible Power System R6000 Models User Guide ...
HP Uninterruptible Power System R6000 Models User Guide
Page 35
Battery replacement is no utility voltage powering the devices. Battery Discharge Firmware Version Select Firmware Version from the Main Menu to 100 percent. UPS On Battery x Alarms Load Power Off The UPS is no ground connection between utility power and the UPS... When the UPS goes into Battery mode, the graph shows the remaining battery energy in 10 percent increments. Main Menu → Firmware Version This menu selection shows the control board firmware version. x x 3-8 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda...
Battery replacement is no utility voltage powering the devices. Battery Discharge Firmware Version Select Firmware Version from the Main Menu to 100 percent. UPS On Battery x Alarms Load Power Off The UPS is no ground connection between utility power and the UPS... When the UPS goes into Battery mode, the graph shows the remaining battery energy in 10 percent increments. Main Menu → Firmware Version This menu selection shows the control board firmware version. x x 3-8 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda...
HP Uninterruptible Power System R6000 Models User Guide
Page 41
...The UPS contains an internal lithium battery and a sealed lead-acid battery module. No user intervention is...batteries. • Do not immerse the batteries in water. • Do not expose to utility power, the UPS automatically charges the batteries. HP Uninterruptible Power System R6000...batteries charged while the UPS is in extended storage. WARNING: To reduce the risk of personal injury from the UPS. • Do not disassemble, crush, or puncture the batteries. • Do not short the external contacts of Batteries," in this chapter for the UPS, including battery charging, replacement...
...The UPS contains an internal lithium battery and a sealed lead-acid battery module. No user intervention is...batteries. • Do not immerse the batteries in water. • Do not expose to utility power, the UPS automatically charges the batteries. HP Uninterruptible Power System R6000...batteries charged while the UPS is in extended storage. WARNING: To reduce the risk of personal injury from the UPS. • Do not disassemble, crush, or puncture the batteries. • Do not short the external contacts of Batteries," in this chapter for the UPS, including battery charging, replacement...
HP Uninterruptible Power System R6000 Models User Guide
Page 42
... the spare designated for UPS R6000 models. Verify that an inventory of personal injury, do not attempt to keep these batteries charged while in the off position. If the LED is 401863-001. Only replace batteries with an internal lithium battery and a sealed lead-acid battery module. Depending on the LCD status menu, replace the batteries module as soon as...
... the spare designated for UPS R6000 models. Verify that an inventory of personal injury, do not attempt to keep these batteries charged while in the off position. If the LED is 401863-001. Only replace batteries with an internal lithium battery and a sealed lead-acid battery module. Depending on the LCD status menu, replace the batteries module as soon as...
HP Uninterruptible Power System R6000 Models User Guide
Page 43
Battery Maintenance Removing the Battery Pack To replace the batteries:. 1. Place the UPS in Manual Bypass mode 2. Figure 4-2: Removing screws from the lower front bezel HP Uninterruptible Power System R6000 Models User Guide 4-3 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/12/02 2:44 PM Using a Philips screwdriver, remove the lower front bezel by backing off the captive screws on each side. Figure 4-1: Placing the UPS in Bypass mode using the manual switch located at the rear of the UPS.
Battery Maintenance Removing the Battery Pack To replace the batteries:. 1. Place the UPS in Manual Bypass mode 2. Figure 4-2: Removing screws from the lower front bezel HP Uninterruptible Power System R6000 Models User Guide 4-3 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/12/02 2:44 PM Using a Philips screwdriver, remove the lower front bezel by backing off the captive screws on each side. Figure 4-1: Placing the UPS in Bypass mode using the manual switch located at the rear of the UPS.
HP Uninterruptible Power System R6000 Models User Guide
Page 44
...: Once the bezel is removed, the battery circuit breakers MUST be in the off position. Battery Maintenance 3. Place the battery circuit breaker in the off position 4. Figure 4-3: Placing the battery circuit breaker in the off position before continuing with the battery replacement. Figure 4-4: Disconnecting the battery cables 4-4 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename...
...: Once the bezel is removed, the battery circuit breakers MUST be in the off position. Battery Maintenance 3. Place the battery circuit breaker in the off position 4. Figure 4-3: Placing the battery circuit breaker in the off position before continuing with the battery replacement. Figure 4-4: Disconnecting the battery cables 4-4 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename...
HP Uninterruptible Power System R6000 Models User Guide
Page 45
... adequate assistance to the equipment: • Observe local Occupational Safety requirements and guidelines for proper disposal. HP Uninterruptible Power System R6000 Models User Guide 4-5 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/12/02 2:44 PM As soon as the replacement batteries are safely in place in this chapter.
... adequate assistance to the equipment: • Observe local Occupational Safety requirements and guidelines for proper disposal. HP Uninterruptible Power System R6000 Models User Guide 4-5 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/12/02 2:44 PM As soon as the replacement batteries are safely in place in this chapter.
HP Uninterruptible Power System R6000 Models User Guide
Page 46
Remove the connector covers from the new batteries and replace the screw used battery housing. 4. When left free during attachment, the connectors provide a positive latch into place. 5. Set the circuit breaker for 24 hours. 4-6 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 2/20/03...
Remove the connector covers from the new batteries and replace the screw used battery housing. 4. When left free during attachment, the connectors provide a positive latch into place. 5. Set the circuit breaker for 24 hours. 4-6 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 2/20/03...
HP Uninterruptible Power System R6000 Models User Guide
Page 48
...• An LED showing that the battery may fail, the battery is replaced free of charge under the warranty. The highest standards in at least two significant ways: • Reduced total cost of ownership • Reduced downtime A Pre-Failure Battery warning is low • Notification from... three years for the first year of ownership includes parts and labor. The warranty for parts. The battery warranty coverage is replaced. 4-8 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/12/02 2:44 PM...
...• An LED showing that the battery may fail, the battery is replaced free of charge under the warranty. The highest standards in at least two significant ways: • Reduced total cost of ownership • Reduced downtime A Pre-Failure Battery warning is low • Notification from... three years for the first year of ownership includes parts and labor. The warranty for parts. The battery warranty coverage is replaced. 4-8 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/12/02 2:44 PM...
HP Uninterruptible Power System R6000 Models User Guide
Page 53
...self-test is flashing yellow. Wait for the self-test to utility power. Contact an authorized service provider. Other than battery replacement, there are on battery power. HP Uninterruptible Power System R6000 Models User Guide 5-5 The UPS is exhausted. The LED is out of range. Reboot the UPS and run a ...self-test. Turn the switch to the UPS must be prepared to lose battery power to complete. Allow the self-test to complete. Utility...
...self-test is flashing yellow. Wait for the self-test to utility power. Contact an authorized service provider. Other than battery replacement, there are on battery power. HP Uninterruptible Power System R6000 Models User Guide 5-5 The UPS is exhausted. The LED is out of range. Reboot the UPS and run a ...self-test. Turn the switch to the UPS must be prepared to lose battery power to complete. Allow the self-test to complete. Utility...
HP Uninterruptible Power System R6000 Models User Guide
Page 58
... with the general household waste. HP Uninterruptible Power System R6000 Models User Guide A-5 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/12/02 7:59 AM WARNING: The UPS contains an internal lithium battery or battery pack. Regulatory Compliance Notices Battery Replacement Notice The UPS is equipped with the HP spare designated...
... with the general household waste. HP Uninterruptible Power System R6000 Models User Guide A-5 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/12/02 7:59 AM WARNING: The UPS contains an internal lithium battery or battery pack. Regulatory Compliance Notices Battery Replacement Notice The UPS is equipped with the HP spare designated...
HP Uninterruptible Power System R6000 Models User Guide
Page 64
... 3-7 altitude, operating C-4 audible alarms 2-6 enabling and disabling 3-11 responding to 5-1 silencing 2-7 audible noise C-4 B backup times C-4 batteries caring for and storing 4-7 charging 2-5, 4-1 determining when to replace 4-2 disposing of 4-7 installing 4-6 obtaining new 4-2 precautions 4-1 Pre-Failure Warranty 4-8 recycling or disposal A-5 removing 4-3, 4-5 runtime C-4 ...3-2, 3-13 controls, front panel 2-1 counting active alarms 3-5 HP Uninterruptible Power System R6000 Models User Guide Index-1 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/12/02 8:26 AM
... 3-7 altitude, operating C-4 audible alarms 2-6 enabling and disabling 3-11 responding to 5-1 silencing 2-7 audible noise C-4 B backup times C-4 batteries caring for and storing 4-7 charging 2-5, 4-1 determining when to replace 4-2 disposing of 4-7 installing 4-6 obtaining new 4-2 precautions 4-1 Pre-Failure Warranty 4-8 recycling or disposal A-5 removing 4-3, 4-5 runtime C-4 ...3-2, 3-13 controls, front panel 2-1 counting active alarms 3-5 HP Uninterruptible Power System R6000 Models User Guide Index-1 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/12/02 8:26 AM
HP Uninterruptible Power System R6000 Models User Guide
Page 65
...depth C-1 determining when to replace batteries 4-2 diagnostics 2-6 dimensions C-1 disconnecting battery cables 4-4 Display Test menu 3-9 display, LCD 2-2 displaying active alarms 3-7 battery data 3-8 firmware versions 3-8 receptacle status 3-5 voltage, frequency, and power 3-6 disposing of used batteries 4-7 E electric shock ...testing 3-9 LCD menus Active Alarms 3-7 Battery Data 3-8 Display Test 3-9 Firmware Version 3-8 Load Control 3-9 Main 3-3 map 3-4 Meters 3-6 Status 3-5 System Setup 3-10 Index-2 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda...
...depth C-1 determining when to replace batteries 4-2 diagnostics 2-6 dimensions C-1 disconnecting battery cables 4-4 Display Test menu 3-9 display, LCD 2-2 displaying active alarms 3-7 battery data 3-8 firmware versions 3-8 receptacle status 3-5 voltage, frequency, and power 3-6 disposing of used batteries 4-7 E electric shock ...testing 3-9 LCD menus Active Alarms 3-7 Battery Data 3-8 Display Test 3-9 Firmware Version 3-8 Load Control 3-9 Main 3-3 map 3-4 Meters 3-6 Status 3-5 System Setup 3-10 Index-2 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda...
HP Uninterruptible Power System R6000 Models User Guide
Page 67
...C-4 Remote Emergency Power Off Port See REPO port removing batteries 4-5 front bezel 4-3 repairing the UPS 5-5 replacing batteries 4-3 REPO port 1-11 RS-232 port See DE9 communication port runtime battery C-4 increasing 1-10 S safety information vii Scalable UPS ...Alarm Reset button 2-1, 2-6, 2-7 testing batteries 4-6 LCD display 3-9 UPS 2-6 text conventions viii U UPS battery maintenance 4-1 configuring 3-1 installing 2-1 models 1-2 operation 2-1 overview 1-1 repairing 5-5 specifications C-1 troubleshooting 5-1 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: ...
...C-4 Remote Emergency Power Off Port See REPO port removing batteries 4-5 front bezel 4-3 repairing the UPS 5-5 replacing batteries 4-3 REPO port 1-11 RS-232 port See DE9 communication port runtime battery C-4 increasing 1-10 S safety information vii Scalable UPS ...Alarm Reset button 2-1, 2-6, 2-7 testing batteries 4-6 LCD display 3-9 UPS 2-6 text conventions viii U UPS battery maintenance 4-1 configuring 3-1 installing 2-1 models 1-2 operation 2-1 overview 1-1 repairing 5-5 specifications C-1 troubleshooting 5-1 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: ...
HP UPS Battery Best Practices
Page 1
..., or their agents. To ensure confidence and meet expectation of the UPS performance, HP recommends proactively replacing the battery at the 3-year point of battery discharges, and charging control. To forward them to recycling or proper disposal, use the public collection ...A unique, three-step charging method provides the extended service life and controls the battery charging for technical or editorial errors or omissions contained herein. HP UPS Battery Best Practices Battery replacement HP UPSs incorporate Extended Runtime Modules (ERMs), which include an exclusive, patented technology...
..., or their agents. To ensure confidence and meet expectation of the UPS performance, HP recommends proactively replacing the battery at the 3-year point of battery discharges, and charging control. To forward them to recycling or proper disposal, use the public collection ...A unique, three-step charging method provides the extended service life and controls the battery charging for technical or editorial errors or omissions contained herein. HP UPS Battery Best Practices Battery replacement HP UPSs incorporate Extended Runtime Modules (ERMs), which include an exclusive, patented technology...
HP UPS Best Practices
Page 1
Page 1 of Use...2 Battery Replacement ...3 Select Load Appropriately / Sizing A UPS 3 Select Application Voltage / High volt VS Low Volt (120V or 208V 3 HP UPS Management...4 HP Power Manager Software...4 HP Management ...
Page 1 of Use...2 Battery Replacement ...3 Select Load Appropriately / Sizing A UPS 3 Select Application Voltage / High volt VS Low Volt (120V or 208V 3 HP UPS Management...4 HP Power Manager Software...4 HP Management ...
HP UPS Best Practices
Page 7
...providing prioritized, sequential shutdown of all network devices Provides details of non-critical devices and extends battery backup for server and storage equipment Industry-leading Power Density The R1500 G2 packs 1340 Watts into just 1U, while the R3000 delivers an...Distribution Units (PDUs) manage power distribution in the industry, reducing total cost of ownership and system downtime HP pre-failure warranty replaces batteries free of charge within 3-year period $250,000 computer load protection guarantee provides additional peace of mind Page 7 of -...
...providing prioritized, sequential shutdown of all network devices Provides details of non-critical devices and extends battery backup for server and storage equipment Industry-leading Power Density The R1500 G2 packs 1340 Watts into just 1U, while the R3000 delivers an...Distribution Units (PDUs) manage power distribution in the industry, reducing total cost of ownership and system downtime HP pre-failure warranty replaces batteries free of charge within 3-year period $250,000 computer load protection guarantee provides additional peace of mind Page 7 of -...
HP UPS Best Practices
Page 12
... warranty is saved during an extended blackout Serial and USB ports for data exchange with the host computer Hot-swappable batteries for simplified service without powering down the UPS Power Management Software o Bundled free with every UPS, the software allows easy UPS...all data is among the longest in the industry, reducing total cost of ownership and system downtime HP pre-failure warranty replaces batteries free of charge within 3-year period $250,000 computer load protection guarantee provides additional peace of mind Page 12 of ...
... warranty is saved during an extended blackout Serial and USB ports for data exchange with the host computer Hot-swappable batteries for simplified service without powering down the UPS Power Management Software o Bundled free with every UPS, the software allows easy UPS...all data is among the longest in the industry, reducing total cost of ownership and system downtime HP pre-failure warranty replaces batteries free of charge within 3-year period $250,000 computer load protection guarantee provides additional peace of mind Page 12 of ...