Implementing Novell NetWare 6.5 on ProLiant servers integration note
Page 1
Implementing Novell NetWare 6.5 on HP ProLiant servers integration note, 3rd edition Abstract...2 Acronyms in text ...2 Introduction to Novell NetWare 6.5 ...3 Supported configurations ...3 Recommended system configuration 3 Server platforms...4 Supported software ...5 Supported storage options ...5 Supported network interface controllers 6 Server management using iLO, iLO2, or RILOE II 10 SmartStart support ...10 Installation procedures...11 Performing a new installation...11 Upgrade...
Implementing Novell NetWare 6.5 on HP ProLiant servers integration note, 3rd edition Abstract...2 Acronyms in text ...2 Introduction to Novell NetWare 6.5 ...3 Supported configurations ...3 Recommended system configuration 3 Server platforms...4 Supported software ...5 Supported storage options ...5 Supported network interface controllers 6 Server management using iLO, iLO2, or RILOE II 10 SmartStart support ...10 Installation procedures...11 Performing a new installation...11 Upgrade...
Implementing Novell NetWare 6.5 on ProLiant servers integration note
Page 2
...abbreviation DNS DOS GUI iLO IP IPX NIC NSS ORCA OS POST PSP RBSU RILOE II SP Acronym expansion Domain Name Server/Service Disk Operating System Graphical User Interface Integrated Lights-Out Internet Protocol Internetwork Packet Exchange Network Interface Controller Novell Storage Services... Pack ROM-Based Setup Utility Remote Insight Lights-Out Edition II Support Pack for Novell NetWare 6.5: • Supported HP ProLiant servers • Recommended configurations • Supported storage options and network adapters • Installation procedures • Known issues and workarounds ...
...abbreviation DNS DOS GUI iLO IP IPX NIC NSS ORCA OS POST PSP RBSU RILOE II SP Acronym expansion Domain Name Server/Service Disk Operating System Graphical User Interface Integrated Lights-Out Internet Protocol Internetwork Packet Exchange Network Interface Controller Novell Storage Services... Pack ROM-Based Setup Utility Remote Insight Lights-Out Edition II Support Pack for Novell NetWare 6.5: • Supported HP ProLiant servers • Recommended configurations • Supported storage options and network adapters • Installation procedures • Known issues and workarounds ...
Implementing Novell NetWare 6.5 on ProLiant servers integration note
Page 4
Descriptions of HP ProLiant server models. Snapshot of the Novell NetWare Support on HP ProLiant Servers Matrix (Figure 1) identifies, by model, the ProLiant servers that have been certified for NetWare 6.5 and include support software from HP. Figure 1. The Novell NetWare Support on HP ProLiant Servers Matrix To view the latest server matrix, visit http://h71028.www7.hp.com/enterprise/cache/470230-0-0-0121.html. Server platforms HP supports Novell NetWare 6.5 on a variety of ProLiant servers are located at www.hp.com/go/proliant. 4
Descriptions of HP ProLiant server models. Snapshot of the Novell NetWare Support on HP ProLiant Servers Matrix (Figure 1) identifies, by model, the ProLiant servers that have been certified for NetWare 6.5 and include support software from HP. Figure 1. The Novell NetWare Support on HP ProLiant Servers Matrix To view the latest server matrix, visit http://h71028.www7.hp.com/enterprise/cache/470230-0-0-0121.html. Server platforms HP supports Novell NetWare 6.5 on a variety of ProLiant servers are located at www.hp.com/go/proliant. 4
Implementing Novell NetWare 6.5 on ProLiant servers integration note
Page 5
Support Pack for example, ProLiant DL380 G5). 4. Table 3. Supported storage options Option Smart Array 6i Smart Array 642 Smart Array 641 Smart Array 6400EM Smart Array 5i Smart Array 532 ... Operating System CD NetWare 6.5 Operating System CD NetWare 6.5 Operating System CD NetWare 6.5 Operating System CD NetWare 6.5 Operating System CD 5 Enter the ProLiant server model (for the quick jump selection. 7. Select the appropriate server model from the HP website as the operating system. 6. Select Novell NetWare 6.5 as follows: 1. Select Software - Select Support and Drivers...
Support Pack for example, ProLiant DL380 G5). 4. Table 3. Supported storage options Option Smart Array 6i Smart Array 642 Smart Array 641 Smart Array 6400EM Smart Array 5i Smart Array 532 ... Operating System CD NetWare 6.5 Operating System CD NetWare 6.5 Operating System CD NetWare 6.5 Operating System CD NetWare 6.5 Operating System CD 5 Enter the ProLiant server model (for the quick jump selection. 7. Select the appropriate server model from the HP website as the operating system. 6. Select Novell NetWare 6.5 as follows: 1. Select Software - Select Support and Drivers...
Implementing Novell NetWare 6.5 on ProLiant servers integration note
Page 10
... the HP website for download (refer to the Supported software section for Novell NetWare 6.5. All support software is available on any supported ProLiant server. Server management using iLO, iLO2, or RILOE II Integrated Lights-Out (iLO), iLO2, or an installed Remote Insight Lights-Out Edition II ...following locations: • For iLO and iLO2: http://h18013.www1.hp.com/products/servers/management/ilo/documentation.html • For RILOE II: http://h18013.www1.hp.com/products/servers/management/riloe2/documentation.html SmartStart support SmartStart 8.00 and later versions do not include ...
... the HP website for download (refer to the Supported software section for Novell NetWare 6.5. All support software is available on any supported ProLiant server. Server management using iLO, iLO2, or RILOE II Integrated Lights-Out (iLO), iLO2, or an installed Remote Insight Lights-Out Edition II ...following locations: • For iLO and iLO2: http://h18013.www1.hp.com/products/servers/management/ilo/documentation.html • For RILOE II: http://h18013.www1.hp.com/products/servers/management/riloe2/documentation.html SmartStart support SmartStart 8.00 and later versions do not include ...
Implementing Novell NetWare 6.5 on ProLiant servers integration note
Page 11
... for the server. a. Power on HP ProLiant Servers Matrix: http://h71028.www7.hp.com/enterprise/cache/470230-0-0-0121.html. 2. For servers with SCSI controllers do not support ORCA, and should be replaced. Servers with array controllers, select F8 during the server reboot to... as the installation type. Use RBSU to begin the configuration of the array controller using the Array Configuration Utility (ACU) found on the server. Performing a new installation 1. In the Boot Controller Setting, choose and/or verify the boot controller. Choose option "I " (Install) ...
... for the server. a. Power on HP ProLiant Servers Matrix: http://h71028.www7.hp.com/enterprise/cache/470230-0-0-0121.html. 2. For servers with SCSI controllers do not support ORCA, and should be replaced. Servers with array controllers, select F8 during the server reboot to... as the installation type. Use RBSU to begin the configuration of the array controller using the Array Configuration Utility (ACU) found on the server. Performing a new installation 1. In the Boot Controller Setting, choose and/or verify the boot controller. Choose option "I " (Install) ...
Implementing Novell NetWare 6.5 on ProLiant servers integration note
Page 19
...HPQCISS.HAM V1.06.02 dated June 19, 2006 ran on an HP ProLiant Server Configured with Two or More HP Smart Array SAS/SATA Controllers to any HP ProLiant server running Novell NetWare 6.5 on ProLiant servers and provides information about resolving them. After the part replacement, install the ...MEMORY CH ECK FLAG = ON to Troubleshoot a NetWare 6.5 Issue on an HP ProLiant Server Description When setting ALLOC MEMORY CHECK FLAG = ON to troubleshoot a NetWare 6.5 issue on an HP ProLiant server, the server may ABEND in a future version of CPQSCSA.NLM will be updated: http://h20000.www2...
...HPQCISS.HAM V1.06.02 dated June 19, 2006 ran on an HP ProLiant Server Configured with Two or More HP Smart Array SAS/SATA Controllers to any HP ProLiant server running Novell NetWare 6.5 on ProLiant servers and provides information about resolving them. After the part replacement, install the ...MEMORY CH ECK FLAG = ON to Troubleshoot a NetWare 6.5 Issue on an HP ProLiant Server Description When setting ALLOC MEMORY CHECK FLAG = ON to troubleshoot a NetWare 6.5 issue on an HP ProLiant server, the server may ABEND in a future version of CPQSCSA.NLM will be updated: http://h20000.www2...
Implementing Novell NetWare 6.5 on ProLiant servers integration note
Page 20
...?lang=en&cc=us&objectID=c00943073. 20 Issue 3 Continuous Beeps and CDM Driver Error Messages May Occur After Rebooting HP ProLiant Server Running NetWare 6.5 SP5 (or Later) With Failed Logical Drive(s) Configured on HP Smart Array SAS/SATA Controller Description After rebooting... a ProLiant server configured with one of the HP Smart Array SAS/SATA Controllers listed in the Scope section (below and running NetWare 6.5 SP5 (or later), high-pitched beeps and console error messages from the Compaq SCSI Custom Device Module for NetWare (HPQCISS...
...?lang=en&cc=us&objectID=c00943073. 20 Issue 3 Continuous Beeps and CDM Driver Error Messages May Occur After Rebooting HP ProLiant Server Running NetWare 6.5 SP5 (or Later) With Failed Logical Drive(s) Configured on HP Smart Array SAS/SATA Controller Description After rebooting... a ProLiant server configured with one of the HP Smart Array SAS/SATA Controllers listed in the Scope section (below and running NetWare 6.5 SP5 (or later), high-pitched beeps and console error messages from the Compaq SCSI Custom Device Module for NetWare (HPQCISS...
Implementing Novell NetWare 6.5 on ProLiant servers integration note
Page 21
...check boxes, then click the "Search" button. Solution To successfully install NetWare 6.5 SP5 on a ProLiant ML570 G3 server, upgrade to the patch is installing NetWare 6.5 SP5. Any HP ProLiant server that is entitled "2974251: Updated NBI an HP hardware discovery issue." 21 Stack pointer: (NWPA.... (NWPA) Page Fault Processor Exception ABEND (Error Code 00000000) on HP ProLiant Servers Configured with HP 8 Internal Port SAS HBA with RAID and Running NetWare 6.5 SP5 and LSIMPTNW.HAM Description HP ProLiant servers configured with the HP 8 Internal Port SAS Host Bus Adapter (HBA) with...
...check boxes, then click the "Search" button. Solution To successfully install NetWare 6.5 SP5 on a ProLiant ML570 G3 server, upgrade to the patch is installing NetWare 6.5 SP5. Any HP ProLiant server that is entitled "2974251: Updated NBI an HP hardware discovery issue." 21 Stack pointer: (NWPA.... (NWPA) Page Fault Processor Exception ABEND (Error Code 00000000) on HP ProLiant Servers Configured with HP 8 Internal Port SAS HBA with RAID and Running NetWare 6.5 SP5 and LSIMPTNW.HAM Description HP ProLiant servers configured with the HP 8 Internal Port SAS Host Bus Adapter (HBA) with...
Implementing Novell NetWare 6.5 on ProLiant servers integration note
Page 23
.../nw65/tcpipenu/data/hc7znq4j.html. Solution To recover from the lost communication when the router attempts to send information to the router. Any ProLiant server running Novell Cluster Services and the HP Gigabit Ethernet NIC Teaming Driver (QASP.LAN), a cluster resource failover from one cluster node to ....LAN) in a NetWare 6.5 Clustering Environment May Result in Discarded "Gratuitous ARP" Packet and Lost Communications After Cluster Resource Failover Description On ProLiant servers running Novell Cluster Services and the HP Gigabit Ethernet NIC Teaming Driver (QASP.LAN).
.../nw65/tcpipenu/data/hc7znq4j.html. Solution To recover from the lost communication when the router attempts to send information to the router. Any ProLiant server running Novell Cluster Services and the HP Gigabit Ethernet NIC Teaming Driver (QASP.LAN), a cluster resource failover from one cluster node to ....LAN) in a NetWare 6.5 Clustering Environment May Result in Discarded "Gratuitous ARP" Packet and Lost Communications After Cluster Resource Failover Description On ProLiant servers running Novell Cluster Services and the HP Gigabit Ethernet NIC Teaming Driver (QASP.LAN).
Implementing Novell NetWare 6.5 on ProLiant servers integration note
Page 25
... SHUTDOWN do not function as expected on HP ProLiant servers that are configured with Intel Dual-Core Xeon 5100 Series Processors and running NetWare 6.5 SP5: • ProLiant DL350 G5 • ProLiant DL360 G5 • ProLiant DL370 G5 • ProLiant DL380 G5 • ProLiant BL20p G4 Server Blade • ProLiant BL460c Server Blade NOTE: The servers listed above are based on Intel Dual...
... SHUTDOWN do not function as expected on HP ProLiant servers that are configured with Intel Dual-Core Xeon 5100 Series Processors and running NetWare 6.5 SP5: • ProLiant DL350 G5 • ProLiant DL360 G5 • ProLiant DL370 G5 • ProLiant DL380 G5 • ProLiant BL20p G4 Server Blade • ProLiant BL460c Server Blade NOTE: The servers listed above are based on Intel Dual...
Implementing Novell NetWare 6.5 on ProLiant servers integration note
Page 27
...pub/nw65sp5.ex e/ AND • iLO 2 Firmware Version 1.01 (or later) To download, go to set PORTENABLE bit: regValue =0x83 Any ProLiant server with HP Integrated Lights-Out 2 (iLO 2) that is running NetWare 6.5 with SP4 (or earlier). HP Integrated Lights-Out 2 (iLO 2) ...Advanced Features Do Not Function on ProLiant Servers with iLO 2 Running NetWare 6.5 Description On a ProLiant server with HP Integrated Lights-Out 2 (iLO 2) running NetWare 6.5 with SP4 (or earlier), the mouse and keyboard will not ...
...pub/nw65sp5.ex e/ AND • iLO 2 Firmware Version 1.01 (or later) To download, go to set PORTENABLE bit: regValue =0x83 Any ProLiant server with HP Integrated Lights-Out 2 (iLO 2) that is running NetWare 6.5 with SP4 (or earlier). HP Integrated Lights-Out 2 (iLO 2) ...Advanced Features Do Not Function on ProLiant Servers with iLO 2 Running NetWare 6.5 Description On a ProLiant server with HP Integrated Lights-Out 2 (iLO 2) running NetWare 6.5 with SP4 (or earlier), the mouse and keyboard will not ...
Implementing Novell NetWare 6.5 on ProLiant servers integration note
Page 28
...Any HP ProLiant DL145, ProLiant DL145 G2, or ProLiant DL385 server that are ...; When running NetWare 6.5 SP3 (or later). Processor 1 activation failed. Issue 16 ProLiant Server with AMD Opteron Processor Running NetWare 6.5 SP3 (or Later) May Stop Responding When...Compaq SCSI Custom Device Module for NetWare (CPQSHD.CDM), or the Novell NetWare SCSI Hard Drive Custom Device Module (SCSIHD.CDM), the server may stop responding and display a Java Exception message. Solution To avoid the server unresponsiveness, perform one of the following: • On an AMD Opteron based ProLiant server...
...Any HP ProLiant DL145, ProLiant DL145 G2, or ProLiant DL385 server that are ...; When running NetWare 6.5 SP3 (or later). Processor 1 activation failed. Issue 16 ProLiant Server with AMD Opteron Processor Running NetWare 6.5 SP3 (or Later) May Stop Responding When...Compaq SCSI Custom Device Module for NetWare (CPQSHD.CDM), or the Novell NetWare SCSI Hard Drive Custom Device Module (SCSIHD.CDM), the server may stop responding and display a Java Exception message. Solution To avoid the server unresponsiveness, perform one of the following: • On an AMD Opteron based ProLiant server...
Implementing Novell NetWare 6.5 on ProLiant servers integration note
Page 29
... with 512 MB RAM and Running NetWare 6.5 May ABEND When Deactivating SYS Volume or When Unloading SYS Volume Driver Description An HP ProLiant server running NetWare 6.5. The following URL: http://support.novell.com/cgi-bin/search/searchtid.cgi?10099897.htm When this occurs, a Page ... is not an HP-specific issue and is documented by the SHUTDOWN command or a critical fan failure). Any HP ProLiant server running NetWare 6.5 may also occur when the server is being rebooted or forcibly shut down (e.g. This is more information becomes available, the advisory will be unloaded by ...
... with 512 MB RAM and Running NetWare 6.5 May ABEND When Deactivating SYS Volume or When Unloading SYS Volume Driver Description An HP ProLiant server running NetWare 6.5. The following URL: http://support.novell.com/cgi-bin/search/searchtid.cgi?10099897.htm When this occurs, a Page ... is not an HP-specific issue and is documented by the SHUTDOWN command or a critical fan failure). Any HP ProLiant server running NetWare 6.5 may also occur when the server is being rebooted or forcibly shut down (e.g. This is more information becomes available, the advisory will be unloaded by ...
ProLiant Essentials Foundation Pack Installation Guide
Page 1
... Utility as constituting an additional warranty. This pack supports HP ProLiant ML and DL 300, 500, and 700 servers, HP ProLiant server blades, and the HP BladeSystem c-Class. • SmartStart - IMPORTANT: Server hardware and array controller configuration is automatically installed after the assisted... The pack includes the following CDs: SmartStart, Management, and ProLiant Firmware Maintenance. • HP is bootable only on HP ProLiant servers. Download the latest Management CD from www.hp.com/servers/manage • Download the latest individual software components from the...
... Utility as constituting an additional warranty. This pack supports HP ProLiant ML and DL 300, 500, and 700 servers, HP ProLiant server blades, and the HP BladeSystem c-Class. • SmartStart - IMPORTANT: Server hardware and array controller configuration is automatically installed after the assisted... The pack includes the following CDs: SmartStart, Management, and ProLiant Firmware Maintenance. • HP is bootable only on HP ProLiant servers. Download the latest Management CD from www.hp.com/servers/manage • Download the latest individual software components from the...
HP ProLiant Servers Troubleshooting Guide
Page 1
HP ProLiant Servers Troubleshooting Guide Part Number 375445-008 July 2009 (Eighth Edition)
HP ProLiant Servers Troubleshooting Guide Part Number 375445-008 July 2009 (Eighth Edition)
HP ProLiant Servers Troubleshooting Guide
Page 3
... (June 2006) ...10 375445-xx4 (May 2006)...11 375445-xx3 (September 2005) ...11 Getting started...12 HP ProLiant 100 Series Server troubleshooting information 12 How to use this guide ...12 Pre-diagnostic steps ...13 Important safety information...13 Symptom information ...16 Prepare ... Power-on problems flowchart ...26 POST problems flowchart ...29 Operating system boot problems flowchart 31 Server fault indications flowchart ...32 Hardware problems ...36 Procedures for all ProLiant servers...36 Power problems ...36 Power source problems ...36 Power supply problems ...36 UPS problems ...37...
... (June 2006) ...10 375445-xx4 (May 2006)...11 375445-xx3 (September 2005) ...11 Getting started...12 HP ProLiant 100 Series Server troubleshooting information 12 How to use this guide ...12 Pre-diagnostic steps ...13 Important safety information...13 Symptom information ...16 Prepare ... Power-on problems flowchart ...26 POST problems flowchart ...29 Operating system boot problems flowchart 31 Server fault indications flowchart ...32 Hardware problems ...36 Procedures for all ProLiant servers...36 Power problems ...36 Power source problems ...36 Power supply problems ...36 UPS problems ...37...
HP ProLiant Servers Troubleshooting Guide
Page 9
Introduction What's new The eighth edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx8, includes the following additions and updates: • Added information to the introduction for the server power-on problems flowchart (on page 26). • Added new steps to Power ... history 375445-xx7 (November 2008) The seventh edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx7, included the following additions and updates: • Added new information about Server updates with an HP Trusted Platform Module and BitLocker™ enabled (on...
Introduction What's new The eighth edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx8, includes the following additions and updates: • Added information to the introduction for the server power-on problems flowchart (on page 26). • Added new steps to Power ... history 375445-xx7 (November 2008) The seventh edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx7, included the following additions and updates: • Added new information about Server updates with an HP Trusted Platform Module and BitLocker™ enabled (on...
HP ProLiant Servers Troubleshooting Guide
Page 10
... document • Updated and added new POST error messages and beep codes (on page 114) 375445-xx6 (September 2007) The sixth edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx6, included the following additions and updates: • Added new information about preventing electrostatic discharge (on page 15). • Added...
... document • Updated and added new POST error messages and beep codes (on page 114) 375445-xx6 (September 2007) The sixth edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx6, included the following additions and updates: • Added new information about preventing electrostatic discharge (on page 15). • Added...
HP ProLiant Servers Troubleshooting Guide
Page 11
375445-xx4 (May 2006) The fourth edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx4, included the following additions: • Hot-plug SAS and SATA hard drive LED combinations (on page 19) • Operating ... error messages (on page 90) and POST error messages and beep codes (on page 114) 375445-xx3 (September 2005) The third edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx3, included the following changes: • Updated SCSI hard drive guidelines • Added hot-plug SCSI hard drive LED combinations...
375445-xx4 (May 2006) The fourth edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx4, included the following additions: • Hot-plug SAS and SATA hard drive LED combinations (on page 19) • Operating ... error messages (on page 90) and POST error messages and beep codes (on page 114) 375445-xx3 (September 2005) The third edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx3, included the following changes: • Updated SCSI hard drive guidelines • Added hot-plug SCSI hard drive LED combinations...