Reference Guide
Page 22
...Configured Stacks Power the units on . After a short interval, they will be added by restoring them . 1. If a serial console connection is desired, the serial cable should be connected to the console port of the unit serving as the Stack Master. Building Manually-Configured Stacks You can... 1. Assign each unit its front panel. Reset the units to be added by restoring them to the factory default mode. 2. Chapter 2 SGE2000/SGE2000P Gigabit Ethernet Switch Reference Guide Building Automatically-Configured Stacks Building a New Stack The easiest way to build a stack is to use a ...
...Configured Stacks Power the units on . After a short interval, they will be added by restoring them . 1. If a serial console connection is desired, the serial cable should be connected to the console port of the unit serving as the Stack Master. Building Manually-Configured Stacks You can... 1. Assign each unit its front panel. Reset the units to be added by restoring them to the factory default mode. 2. Chapter 2 SGE2000/SGE2000P Gigabit Ethernet Switch Reference Guide Building Automatically-Configured Stacks Building a New Stack The easiest way to build a stack is to use a ...
Software Configuration Guide
Page 32
... interfaces module • N2232P and N2232TM-32 10-Gigabit SFP+ Ethernet host interfaces and 8 10-Gigabit SFP+ Ethernet fabric interfaces module Cisco Nexus 2000 Series NX-OS Fabric Extender Software Configuration Guide 22 OL-25816-02 The range of the FEX-number is one of Fabric ...Extender. Example: switch(config-fex)# no serial DETAILED STEPS Step 1 Step 2 Step 3 Step 4 Step 5 Command or Action configure terminal Purpose Enters configuration mode. FEX-type is from 101 ...
... interfaces module • N2232P and N2232TM-32 10-Gigabit SFP+ Ethernet host interfaces and 8 10-Gigabit SFP+ Ethernet fabric interfaces module Cisco Nexus 2000 Series NX-OS Fabric Extender Software Configuration Guide 22 OL-25816-02 The range of the FEX-number is one of Fabric ...Extender. Example: switch(config-fex)# no serial DETAILED STEPS Step 1 Step 2 Step 3 Step 4 Step 5 Command or Action configure terminal Purpose Enters configuration mode. FEX-type is from 101 ...
Software Configuration Guide
Page 33
... Fabric Extender in the binary configuration on the parent switch, all configurations for all interfaces on the Fabric Extender are deleted. (Optional) Defines a serial number string. The parent Cisco Nexus Series device remembers the type of FEX configurations. Configuring the Fabric Extender Configuration Examples Step 6 Step 7 Step 8 Command or Action no type...
... Fabric Extender in the binary configuration on the parent switch, all configurations for all interfaces on the Fabric Extender are deleted. (Optional) Defines a serial number string. The parent Cisco Nexus Series device remembers the type of FEX configurations. Configuring the Fabric Extender Configuration Examples Step 6 Step 7 Step 8 Command or Action no type...
Software Configuration Guide
Page 37
...Po101 Eth101/1/26 Down Po101 Po101 Eth101/1/27 Down Po101 Po101 Eth101/1/28 Down Po101 Po101 Eth101/1/29 Down Po101 Po101 OL-25816-02 Cisco Nexus 2000 Series NX-OS Fabric Extender Software Configuration Guide 27 State: Active Eth4/2 - Interface Up. State: Active Eth2/1 - Displays... FEX0101 state: Online FEX version: 5.1(1) [Switch version: 5.1(1)] FEX Interim version: 5.1(0.159.6) Switch Interim version: 5.1(1) Extender Model: N2K-C2248TP-1GE, Extender Serial: JAF1418AARL Part No: 73-12748-05 Card Id: 99, Mac Addr: 54:75:d0:a9:49:42, Num Macs: 64 Module Sw Gen: 21 ...
...Po101 Eth101/1/26 Down Po101 Po101 Eth101/1/27 Down Po101 Po101 Eth101/1/28 Down Po101 Po101 Eth101/1/29 Down Po101 Po101 OL-25816-02 Cisco Nexus 2000 Series NX-OS Fabric Extender Software Configuration Guide 27 State: Active Eth4/2 - Interface Up. State: Active Eth2/1 - Displays... FEX0101 state: Online FEX version: 5.1(1) [Switch version: 5.1(1)] FEX Interim version: 5.1(0.159.6) Switch Interim version: 5.1(1) Extender Model: N2K-C2248TP-1GE, Extender Serial: JAF1418AARL Part No: 73-12748-05 Card Id: 99, Mac Addr: 54:75:d0:a9:49:42, Num Macs: 64 Module Sw Gen: 21 ...
Software Configuration Guide
Page 38
... ethernet 1/40 transceiver Ethernet1/40 sfp is present name is CISCO-MOLEX INC part number is 74752-9026 revision is A0 serial number is MOC13321057 nominal bitrate is 12000 MBits/sec Link length supported for copper is 3 m(s) cisco id is -cisco extended id number is 4 This example shows how to display...on the Fabric Extender: switch# show interface ethernet 1/40 transceiver fex-fabric Ethernet1/40 sfp is present name is CISCO-MOLEX INC part number is 74752-9026 revision is A0 serial number is MOC13321057 nominal bitrate is 12000 MBits/sec Link length supported for 50/125mm fiber is 0 m(s) Link...
... ethernet 1/40 transceiver Ethernet1/40 sfp is present name is CISCO-MOLEX INC part number is 74752-9026 revision is A0 serial number is MOC13321057 nominal bitrate is 12000 MBits/sec Link length supported for copper is 3 m(s) cisco id is -cisco extended id number is 4 This example shows how to display...on the Fabric Extender: switch# show interface ethernet 1/40 transceiver fex-fabric Ethernet1/40 sfp is present name is CISCO-MOLEX INC part number is 74752-9026 revision is A0 serial number is MOC13321057 nominal bitrate is 12000 MBits/sec Link length supported for 50/125mm fiber is 0 m(s) Link...
Software Configuration Guide
Page 39
... show environment fex {all | FEX-number} [temperature | power | fan] Displays the environmental sensor status. FEX Mod MAC-Address(es) Serial-Num 101 1 5475.d0a9.4940 to 5475.d0a9.496f JAF1418AARL This example shows how to display the inventory information about all connected Fabric Extender units... is -cisco extended id number is 4 The following example shows how to display the status of the feature sets on the switch supervisor to manage the Fabric Extender, perform one of the serial PROM (SPROM) on the Fabric Extender. show inventory fex FEX-number Displays inventory...
... show environment fex {all | FEX-number} [temperature | power | fan] Displays the environmental sensor status. FEX Mod MAC-Address(es) Serial-Num 101 1 5475.d0a9.4940 to 5475.d0a9.496f JAF1418AARL This example shows how to display the inventory information about all connected Fabric Extender units... is -cisco extended id number is 4 The following example shows how to display the status of the feature sets on the switch supervisor to manage the Fabric Extender, perform one of the serial PROM (SPROM) on the Fabric Extender. show inventory fex FEX-number Displays inventory...
Software Configuration Guide
Page 41
... Checksum : 0x1a1e EEPROM Size : 65535 Block Count :3 FRU Major Type : 0x6002 FRU Minor Type : 0x0 OEM String : Cisco Systems, Inc. Product Number : N2K-C2248TP-1GE Serial Number : SSI13380FSM Part Number : 68-3601-01 Part Revision : 03 Mfg Deviation : 0 H/W Version : 1.0 Mfg Bits...Checksum : 0x2cf Feature Bits : 0x0 Verifying the Chassis Management Information OL-25816-02 Cisco Nexus 2000 Series NX-OS Fabric Extender Software Configuration Guide 31 Product Number : N2K-C2248TP-1GE Serial Number : JAF1339BDSK Part Number : 73-12748-01 Part Revision : 11 Mfg Deviation ...
... Checksum : 0x1a1e EEPROM Size : 65535 Block Count :3 FRU Major Type : 0x6002 FRU Minor Type : 0x0 OEM String : Cisco Systems, Inc. Product Number : N2K-C2248TP-1GE Serial Number : SSI13380FSM Part Number : 68-3601-01 Part Revision : 03 Mfg Deviation : 0 H/W Version : 1.0 Mfg Bits...Checksum : 0x2cf Feature Bits : 0x0 Verifying the Chassis Management Information OL-25816-02 Cisco Nexus 2000 Series NX-OS Fabric Extender Software Configuration Guide 31 Product Number : N2K-C2248TP-1GE Serial Number : JAF1339BDSK Part Number : 73-12748-01 Part Revision : 11 Mfg Deviation ...
Software Configuration Guide
Page 42
... Checksum : 0x1673 EEPROM Size : 65535 Block Count :2 FRU Major Type : 0xab01 FRU Minor Type : 0x0 OEM String : Cisco Systems Inc NXK-PAC-400W Product Number : NXK-PAC-400W Serial Number : LIT13370QD6 Part Number : 341 Part Revision : -037 CLEI Code : 5-01 01 000 VID : 000 snmpOID :... 12336.12336.12336.12336.12336.12336.12374.12336 H/W Version : 43777.2 Current : 36 Cisco Nexus 2000 Series NX-OS Fabric Extender ...
... Checksum : 0x1673 EEPROM Size : 65535 Block Count :2 FRU Major Type : 0xab01 FRU Minor Type : 0x0 OEM String : Cisco Systems Inc NXK-PAC-400W Product Number : NXK-PAC-400W Serial Number : LIT13370QD6 Part Number : 341 Part Revision : -037 CLEI Code : 5-01 01 000 VID : 000 snmpOID :... 12336.12336.12336.12336.12336.12336.12374.12336 H/W Version : 43777.2 Current : 36 Cisco Nexus 2000 Series NX-OS Fabric Extender ...
Software Configuration Guide
Page 46
...channel fabric interface 2, 3 port channel host interface 2 port numbering 9 priority flow control, See PFC Q QoS 5 quality-of-service, See QoS R related documents 33 S serial number 21 SFP+ validation 3 show diagnostics 29 show environment 29 show fex 26 show inventory 29 show modules 29 show SPROM 29 show transceiver status... 26 SPAN restrictions 6 SPAN source ports 6 subinterfaces 3 switchport fex-fabric mode 3 switchport saved configuration 3 T type 21 V version compatibility 10 VLANs 5 Cisco Nexus 2000 Series NX-OS Fabric Extender Software Configuration Guide IN-2 OL-25816-02
...channel fabric interface 2, 3 port channel host interface 2 port numbering 9 priority flow control, See PFC Q QoS 5 quality-of-service, See QoS R related documents 33 S serial number 21 SFP+ validation 3 show diagnostics 29 show environment 29 show fex 26 show inventory 29 show modules 29 show SPROM 29 show transceiver status... 26 SPAN restrictions 6 SPAN source ports 6 subinterfaces 3 switchport fex-fabric mode 3 switchport saved configuration 3 T type 21 V version compatibility 10 VLANs 5 Cisco Nexus 2000 Series NX-OS Fabric Extender Software Configuration Guide IN-2 OL-25816-02
Configuration Guide
Page 24
...crossrail supports for 19" rack with front and back posts • Fast Ethernet cable for connecting to the Management ports • RS-232 serial cable (DB-9 to RJ-45) for connecting to a local terminal Two AC power supply cords,if ordered with each system. To order documents...; Grounding cable • Two Hex nuts (#¼") • Two spring washers (#¼") If ordered, SCE 2000 hardware and software documentation set and the Cisco Documentation CD-ROM package* Four rubber feet for tabletop installation • 1 External Optical Bypass module • 1 19" rack mounting panel • 1...
...crossrail supports for 19" rack with front and back posts • Fast Ethernet cable for connecting to the Management ports • RS-232 serial cable (DB-9 to RJ-45) for connecting to a local terminal Two AC power supply cords,if ordered with each system. To order documents...; Grounding cable • Two Hex nuts (#¼") • Two spring washers (#¼") If ordered, SCE 2000 hardware and software documentation set and the Cisco Documentation CD-ROM package* Four rubber feet for tabletop installation • 1 External Optical Bypass module • 1 19" rack mounting panel • 1...
Configuration Guide
Page 66
... any prompt. Default settings are not configurable. Plug the RS-232 serial cable provided with an attached DB-9 connector) to the VT100 compatible local (serial) terminal. 3. Connect the other end of the SCE 2000 . Cisco SCE 2000 4xGBE Installation and Configuration Guide 5-2 OL-7824-06 Make ...DETAILED STEPS Step 1 Step 2 Step 3 Step 4 Step 5 Plug the RS-232 serial cable provided with the System Configuration Dialog? [yes/no]: y Type yand press Enter. Press Enter several times until the Cisco logo appears on the plug to confirm whether the plug is entered. 5. Would you ...
... any prompt. Default settings are not configurable. Plug the RS-232 serial cable provided with an attached DB-9 connector) to the VT100 compatible local (serial) terminal. 3. Connect the other end of the SCE 2000 . Cisco SCE 2000 4xGBE Installation and Configuration Guide 5-2 OL-7824-06 Make ...DETAILED STEPS Step 1 Step 2 Step 3 Step 4 Step 5 Plug the RS-232 serial cable provided with the System Configuration Dialog? [yes/no]: y Type yand press Enter. Press Enter several times until the Cisco logo appears on the plug to confirm whether the plug is entered. 5. Would you ...
Configuration Guide
Page 117
...: V01, SN: CAT093604K3 SCE 2000> How to Display the System Uptime Use this command to remotely manage the assets in the Cisco Service Control Engine (SCE) Software Configuration Guide ) • CLI show inventorycommand The show inventoryCLI command displays the following example shows how...Device name • Description • Product identifier • Version identifier • Serial number Step 1 From the SCE 2000>prompt, type show system-uptimeSCE 2000 uptime is supported by all Cisco platforms. This feature allows network administrators to see Final Tests in their network by ...
...: V01, SN: CAT093604K3 SCE 2000> How to Display the System Uptime Use this command to remotely manage the assets in the Cisco Service Control Engine (SCE) Software Configuration Guide ) • CLI show inventorycommand The show inventoryCLI command displays the following example shows how...Device name • Description • Product identifier • Version identifier • Serial number Step 1 From the SCE 2000>prompt, type show system-uptimeSCE 2000 uptime is supported by all Cisco platforms. This feature allows network administrators to see Final Tests in their network by ...
Configuration Guide
Page 118
... the commands for that firmware to confirm the reboot request and press Enter. SUMMARY STEPS 1. Type y to the serial console port (The CON connector on the SCE platform front panel, 9600 baud). 7-10 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 This helps to ensure that non-volatile memory...
... the commands for that firmware to confirm the reboot request and press Enter. SUMMARY STEPS 1. Type y to the serial console port (The CON connector on the SCE platform front panel, 9600 baud). 7-10 Cisco SCE 2000 4xGBE Installation and Configuration Guide OL-7824-06 This helps to ensure that non-volatile memory...
Configuration Guide
Page 119
The SCE 2000# prompt appears. OL-7824-06 Cisco SCE 2000 4xGBE Installation and Configuration Guide 7-11 Type reload shutdown. 3. Step 1 Step 2 Step 3 Connect to the serial console port (The CON connector on . Type y to confirm the shutdown request and press Enter. Continue? This ...limitation helps prevent situations in which a user issues this command from the serial CLI console. A confirmation message appears. Type y to confirm the shutdown request and press Enter. The only way to resume system operation...
The SCE 2000# prompt appears. OL-7824-06 Cisco SCE 2000 4xGBE Installation and Configuration Guide 7-11 Type reload shutdown. 3. Step 1 Step 2 Step 3 Connect to the serial console port (The CON connector on . Type y to confirm the shutdown request and press Enter. Continue? This ...limitation helps prevent situations in which a user issues this command from the serial CLI console. A confirmation message appears. Type y to confirm the shutdown request and press Enter. The only way to resume system operation...
Configuration Guide
Page 121
...H A P T E R • Troubleshooting Overview • Troubleshooting with the following information: • Date you received the router • Chassis serial number • Type of software and release number • Brief description of the problem you have taken to a specific subsystem and resolve the problem ...and describes how the SCE 2000 platform is divided into subsystems for more efficient problem solving. OL-7824-06 Cisco SCE 2000 4xGBE Installation and Configuration Guide 8-1 Provide the representative with the User Log Troubleshooting Overview This section describes...
...H A P T E R • Troubleshooting Overview • Troubleshooting with the following information: • Date you received the router • Chassis serial number • Type of software and release number • Brief description of the problem you have taken to a specific subsystem and resolve the problem ...and describes how the SCE 2000 platform is divided into subsystems for more efficient problem solving. OL-7824-06 Cisco SCE 2000 4xGBE Installation and Configuration Guide 8-1 Provide the representative with the User Log Troubleshooting Overview This section describes...