Quick Start Guide
Page 1
Quick Start Guide Cisco Small Business Cisco Unmanaged Rackmount Switches Package Contents • Cisco SF 100-16, SF 100-24, SF 102-24, SG 100-16, SG 100-24, or SG 102-24 Unmanaged Rackmount Switch • Rackmount Kit • Power Cord • This Quick Start Guide
Quick Start Guide Cisco Small Business Cisco Unmanaged Rackmount Switches Package Contents • Cisco SF 100-16, SF 100-24, SF 102-24, SG 100-16, SG 100-24, or SG 102-24 Unmanaged Rackmount Switch • Rackmount Kit • Power Cord • This Quick Start Guide
Quick Start Guide
Page 2
... jumbo frames. Auto MDI/MDI-X crossover detection automatically adjusts for choosing the Cisco SF 100-16, SF 100-24, SF 102-24, SG 100-16, SG 100-24, or SG 102-24 Unmanaged Rackmount Switch, a Cisco Small Business network communications device. all received packets are given priority over data... traffic. or full-duplex) for QoS priority encoding. Jumbo Frame Support SG 100-16, SG 100-24, and SG 102-24 switches support frames up to other ...
... jumbo frames. Auto MDI/MDI-X crossover detection automatically adjusts for choosing the Cisco SF 100-16, SF 100-24, SF 102-24, SG 100-16, SG 100-24, or SG 102-24 Unmanaged Rackmount Switch, a Cisco Small Business network communications device. all received packets are given priority over data... traffic. or full-duplex) for QoS priority encoding. Jumbo Frame Support SG 100-16, SG 100-24, and SG 102-24 switches support frames up to other ...
Quick Start Guide
Page 3
... Flow-Both side panels must be level, stable, and secure to avoid it sliding or shifting out of position. Cisco Unmanaged Rackmount Switches 2 Mechanical Overloading-The device should be unobstructed to the power outlet must not exceed 104 degrees Fahrenheit (40C). When... you install the Unmanaged Rackmount Switch, follow the guidelines in a standard rack (1U high). • Mount the switch on a wall. Circuit Overloading-Adding the device to prevent overheating. 1 Installing the Cisco Switch There are three ways to provide a minimum clearance ...
... Flow-Both side panels must be level, stable, and secure to avoid it sliding or shifting out of position. Cisco Unmanaged Rackmount Switches 2 Mechanical Overloading-The device should be unobstructed to the power outlet must not exceed 104 degrees Fahrenheit (40C). When... you install the Unmanaged Rackmount Switch, follow the guidelines in a standard rack (1U high). • Mount the switch on a wall. Circuit Overloading-Adding the device to prevent overheating. 1 Installing the Cisco Switch There are three ways to provide a minimum clearance ...
Quick Start Guide
Page 4
...at least 1.5mm. STEP 1 Place the switch on a hard, flat surface with 24) miniGBIC1 miniGBIC2 Cisco Small Business SR2024 10/100/1000 24-Port Switch 193086 Wall Mounting A Cisco SF 100-16, SF 100-24, SG 100-16, or SG 102-24 Unmanaged Rackmount Switch can be wall-mounted. STEP 3 After ...the brackets are attached to the switch, use suitable screws to securely...
...at least 1.5mm. STEP 1 Place the switch on a hard, flat surface with 24) miniGBIC1 miniGBIC2 Cisco Small Business SR2024 10/100/1000 24-Port Switch 193086 Wall Mounting A Cisco SF 100-16, SF 100-24, SG 100-16, or SG 102-24 Unmanaged Rackmount Switch can be wall-mounted. STEP 3 After ...the brackets are attached to the switch, use suitable screws to securely...
Quick Start Guide
Page 5
...13 14 15 16 5 6 7 8 17 18 19 20 9 10 11 12 21 22 23 24 (Shared with 12) (Shared with 24) miniGBIC1 miniGBIC2 Cisco Small Business SR2024 24-P or t 10/ 100/ 1000 Swit ch 193803 Cisco Unmanaged Rackmount Switches 4 STEP 4 Place the unmanaged rackmount switch wall-mount ...slots over the screws and slide the unmanaged rackmount switch down until the screws fit snugly...
...13 14 15 16 5 6 7 8 17 18 19 20 9 10 11 12 21 22 23 24 (Shared with 12) (Shared with 24) miniGBIC1 miniGBIC2 Cisco Small Business SR2024 24-P or t 10/ 100/ 1000 Swit ch 193803 Cisco Unmanaged Rackmount Switches 4 STEP 4 Place the unmanaged rackmount switch wall-mount ...slots over the screws and slide the unmanaged rackmount switch down until the screws fit snugly...
Quick Start Guide
Page 6
...the port. NOTE If the uplink from one unmanaged, cascaded switch to another port, it can take up to five minutes for each device you want to connect to the switch and a power source. 5 Cisco Unmanaged Rackmount Switches Otherwise, flow control might not be configurable. To connect the... unmanaged rackmount switch to the network: STEP 1 Connect the Ethernet cable to the Ethernet port of a...
...the port. NOTE If the uplink from one unmanaged, cascaded switch to another port, it can take up to five minutes for each device you want to connect to the switch and a power source. 5 Cisco Unmanaged Rackmount Switches Otherwise, flow control might not be configurable. To connect the... unmanaged rackmount switch to the network: STEP 1 Connect the Ethernet cable to the Ethernet port of a...
Quick Start Guide
Page 7
... clients. Front Panel LEDs System LED-Lights green when the switch is a combination port, shared with Cisco miniGBIC modules MGBSX1, MGBLH1, MGBT1, MGBLX1, and MGBBX1, as well as other RJ-45 interface. Cisco Unmanaged Rackmount Switches 6 The auto-sensing, Ethernet (802.3) ports are compatible ...with one other brands of miniGBIC modules. • MiniGBIC interface is powered on the front panel of the switch. 1 13 2 14 3 15 4 16 5 17 6 18 7 19 8 20 ...
... clients. Front Panel LEDs System LED-Lights green when the switch is a combination port, shared with Cisco miniGBIC modules MGBSX1, MGBLH1, MGBT1, MGBLX1, and MGBBX1, as well as other RJ-45 interface. Cisco Unmanaged Rackmount Switches 6 The auto-sensing, Ethernet (802.3) ports are compatible ...with one other brands of miniGBIC modules. • MiniGBIC interface is powered on the front panel of the switch. 1 13 2 14 3 15 4 16 5 17 6 18 7 19 8 20 ...
Quick Start Guide
Page 8
... Side Panel The Kensington lock is located on the back panel of the unmanaged rackmount switch. (Only the Cisco SF 100-16, SF 100-24, SG 100-16, or SG 102-24 Unmanaged Rackmount Switch has a lock.) 276580 276581 7 Cisco Unmanaged Rackmount Switches 100M LED (if present)-(Green) Lights and remains lit when another device is connected...
... Side Panel The Kensington lock is located on the back panel of the unmanaged rackmount switch. (Only the Cisco SF 100-16, SF 100-24, SG 100-16, or SG 102-24 Unmanaged Rackmount Switch has a lock.) 276580 276581 7 Cisco Unmanaged Rackmount Switches 100M LED (if present)-(Green) Lights and remains lit when another device is connected...
Quick Start Guide
Page 9
... list the specifications for the unmanaged rackmount switches. Weights and Dimensions Model SF 100-16 16 RJ-45 10/100 ports SF 100-24 24 RJ-45 10/100 ports SF 102-24 24 RJ-45 10/100 ports, 2 shared Gigabit RJ-45/miniGBIC ports SG 100-16 16 RJ-45 10/100/1000 ports....4x44.45x170 440x44.45x202.5 279.4x44.45x170 Dimensions Inch 11x1.75x6.7 11x1.75x6.7 17.35x1.74x7.99 11x1.75x6.7 17.35x1.74x7.99 11x1.75x6.7 Cisco Unmanaged Rackmount Switches 8
... list the specifications for the unmanaged rackmount switches. Weights and Dimensions Model SF 100-16 16 RJ-45 10/100 ports SF 100-24 24 RJ-45 10/100 ports SF 102-24 24 RJ-45 10/100 ports, 2 shared Gigabit RJ-45/miniGBIC ports SG 100-16 16 RJ-45 10/100/1000 ports....4x44.45x170 440x44.45x202.5 279.4x44.45x170 Dimensions Inch 11x1.75x6.7 11x1.75x6.7 17.35x1.74x7.99 11x1.75x6.7 17.35x1.74x7.99 11x1.75x6.7 Cisco Unmanaged Rackmount Switches 8
Quick Start Guide
Page 10
Features Feature Standards Cabling Type Physical Security Power Certification Operating Temperature Storage Temperature Operating Humidity Storage Humidity Description IEEE 802.3, 802.3u, 802.3x, 802.3ab, 802.3z, and 802.1p Category 5 or better Kensington security slot on a Cisco SF 100-16, SF 100-24, SG 100-16, or SG 102-24 Unmanaged Rackmount Switch 100V-240V~ 1A 50-60 Hz FCC Class A, CE 32 to 104ºF (0 to 40ºC) -4 to 158ºF (-20 to 70ºC) 10% to 90% Relative Humidity, noncondensing 10% to 90% Relative Humidity, noncondensing 9 Cisco Unmanaged Rackmount Switches
Features Feature Standards Cabling Type Physical Security Power Certification Operating Temperature Storage Temperature Operating Humidity Storage Humidity Description IEEE 802.3, 802.3u, 802.3x, 802.3ab, 802.3z, and 802.1p Category 5 or better Kensington security slot on a Cisco SF 100-16, SF 100-24, SG 100-16, or SG 102-24 Unmanaged Rackmount Switch 100V-240V~ 1A 50-60 Hz FCC Class A, CE 32 to 104ºF (0 to 40ºC) -4 to 158ºF (-20 to 70ºC) 10% to 90% Relative Humidity, noncondensing 10% to 90% Relative Humidity, noncondensing 9 Cisco Unmanaged Rackmount Switches
Quick Start Guide
Page 11
... Business Community www.cisco.com/smb Cisco Small Business Support www.cisco.com/go/smallbizsupport Community Online Technical Support and www.cisco.com/support Documentation (Login Required) Phone Support Contacts www.cisco.com/en/US/support/tsd_cisco_ small_business_support_center_contacts.html Product Documentation Cisco Unmanaged Rackmount Switches Quick Start Guide www.cisco.com/en/US/docs/switches/lan/ csbus/sf10x-xx_sg10x...
... Business Community www.cisco.com/smb Cisco Small Business Support www.cisco.com/go/smallbizsupport Community Online Technical Support and www.cisco.com/support Documentation (Login Required) Phone Support Contacts www.cisco.com/en/US/support/tsd_cisco_ small_business_support_center_contacts.html Product Documentation Cisco Unmanaged Rackmount Switches Quick Start Guide www.cisco.com/en/US/docs/switches/lan/ csbus/sf10x-xx_sg10x...