Specifications
Page 1
Spec Sheet Cisco UCS B200 M2 Blade Server CISCO SYSTEMS 170 WEST TASMAN DR. SAN JOSE, CA, 95134 WWW.CISCO.COM PUBLICATION HISTORY REV A.1 MARCH 9, 2012
Spec Sheet Cisco UCS B200 M2 Blade Server CISCO SYSTEMS 170 WEST TASMAN DR. SAN JOSE, CA, 95134 WWW.CISCO.COM PUBLICATION HISTORY REV A.1 MARCH 9, 2012
Specifications
Page 2
... 25 SUPPLEMENTAL MATERIAL 26 Motherboard 26 DIMM and CPU Layout 26 Memory Population Recommendations 27 TECHNICAL SPECIFICATIONS 29 Dimensions and Weight 29 Power Specifications 29 Cisco UCS B200 M2 Blade Server 2
... 25 SUPPLEMENTAL MATERIAL 26 Motherboard 26 DIMM and CPU Layout 26 Memory Population Recommendations 27 TECHNICAL SPECIFICATIONS 29 Dimensions and Weight 29 Power Specifications 29 Cisco UCS B200 M2 Blade Server 2
Specifications
Page 3
Figure 1 Cisco UCS B200 M2 Blade Server Cisco UCS B200 M2 Blade Server 3 Up to two solid-state disk (SSD) drives or hard disk drives (HDDs). OVERVIEW OVERVIEW The Cisco UCS B200 M2 Blade Server (Figure 1) Server is a two-socket, half-width blade server, using Intel's Xeon 5500 and 5600 Series processors with 12 DIMM slots, one mezzanine slot to hold an adapter card, and up to eight half-width blade servers can be accommodated in the Cisco UCS 5108 Blade Server Chassis.
Figure 1 Cisco UCS B200 M2 Blade Server Cisco UCS B200 M2 Blade Server 3 Up to two solid-state disk (SSD) drives or hard disk drives (HDDs). OVERVIEW OVERVIEW The Cisco UCS B200 M2 Blade Server (Figure 1) Server is a two-socket, half-width blade server, using Intel's Xeon 5500 and 5600 Series processors with 12 DIMM slots, one mezzanine slot to hold an adapter card, and up to eight half-width blade servers can be accommodated in the Cisco UCS 5108 Blade Server Chassis.
Specifications
Page 4
... information about the KVM device included in the chassis accessory kit that plugs into the console connector, see ORDER OPTIONAL KVM CABLE on page 25. 4 Cisco UCS B200 M2 Blade Server Figure 2 Chassis Front View 4 5 1 2 3 6 78 9 10 11 1 Asset tag (you can remove this tag and 7 Network link status LED add your...) 11 Beaconing LED and button 6 Power button and LED Notes . . . 1. 195354 DETAILED VIEWS DETAILED VIEWS Chassis Front View Figure 2 is a detailed front view of the Cisco UCS B200 M2 Blade Server.
... information about the KVM device included in the chassis accessory kit that plugs into the console connector, see ORDER OPTIONAL KVM CABLE on page 25. 4 Cisco UCS B200 M2 Blade Server Figure 2 Chassis Front View 4 5 1 2 3 6 78 9 10 11 1 Asset tag (you can remove this tag and 7 Network link status LED add your...) 11 Beaconing LED and button 6 Power button and LED Notes . . . 1. 195354 DETAILED VIEWS DETAILED VIEWS Chassis Front View Figure 2 is a detailed front view of the Cisco UCS B200 M2 Blade Server.
Specifications
Page 5
...The first 8 MB of memory are provided in CONFIGURING the SERVER on page 25) Integrated in the Cisco UCS 5100 series chassis Integrated in the Cisco UCS 5100 series chassis The built-in a Cisco UCS 5100-series chassis Either 1 or 2 Intel® Xeon® 5500 or 5600 series processors Intel®...; 5500 chipset 12 slots for example, number of processors, disk drives, or amount of the base server. Cisco UCS B200 M2 Blade Server 5 The server CIMC chip includes a Matrox G200 core. Table 1 Capabilities and Features Capability/Feature Chassis CPU Chipset ...
...The first 8 MB of memory are provided in CONFIGURING the SERVER on page 25) Integrated in the Cisco UCS 5100 series chassis Integrated in the Cisco UCS 5100 series chassis The built-in a Cisco UCS 5100-series chassis Either 1 or 2 Intel® Xeon® 5500 or 5600 series processors Intel®...; 5500 chipset 12 slots for example, number of processors, disk drives, or amount of the base server. Cisco UCS B200 M2 Blade Server 5 The server CIMC chip includes a Matrox G200 core. Table 1 Capabilities and Features Capability/Feature Chassis CPU Chipset ...
Specifications
Page 6
CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS B200 Blade Server: ■ STEP 1 VERIFY BASE SKU, page 7 ■ STEP 2 CHOOSE CPU(S), page 8 ■ STEP 3 CHOOSE MEMORY, page 10 ■ STEP 4 CHOOSE HARD DISK ... 7 CHOOSE OPERATING SYSTEM MEDIA KIT, page 19 ■ STEP 8 CHOOSE OPTIONAL VALUE-ADDED SOFTWARE, page 20 ■ STEP 9 CHOOSE SERVICE and SUPPORT LEVEL, page 21 6 Cisco UCS B200 M2 Blade Server
CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS B200 Blade Server: ■ STEP 1 VERIFY BASE SKU, page 7 ■ STEP 2 CHOOSE CPU(S), page 8 ■ STEP 3 CHOOSE MEMORY, page 10 ■ STEP 4 CHOOSE HARD DISK ... 7 CHOOSE OPERATING SYSTEM MEDIA KIT, page 19 ■ STEP 8 CHOOSE OPTIONAL VALUE-ADDED SOFTWARE, page 20 ■ STEP 9 CHOOSE SERVICE and SUPPORT LEVEL, page 21 6 Cisco UCS B200 M2 Blade Server
Specifications
Page 7
KVM cable ■ Does not include: - Mezzanine adapter card NOTE: Use the steps on the following pages to configure the server with the components that you want to include. Table 2 PID of the base server as shown in Table 2. Cisco UCS B200 M2 Blade Server 7 CPUs - Memory - Disk drives - CONFIGURING the SERVER STEP 1 VERIFY BASE SKU Verify the product ID (PID) of the Base B200 M2 Blade Server Product ID (PID) Description N20-B6625-1-UPG UCS B200 M2 Blade Server w/o CPU, memory, HDD, mezzanine The N20-B6625-1-UPG B200 M2 base server: ■ Includes: -
KVM cable ■ Does not include: - Mezzanine adapter card NOTE: Use the steps on the following pages to configure the server with the components that you want to include. Table 2 PID of the base server as shown in Table 2. Cisco UCS B200 M2 Blade Server 7 CPUs - Memory - Disk drives - CONFIGURING the SERVER STEP 1 VERIFY BASE SKU Verify the product ID (PID) of the Base B200 M2 Blade Server Product ID (PID) Description N20-B6625-1-UPG UCS B200 M2 Blade Server w/o CPU, memory, HDD, mezzanine The N20-B6625-1-UPG B200 M2 base server: ■ Includes: -
Specifications
Page 8
Table 3 Available Intel CPUs: Xeon Westmere-EP x56xx Family Product ID (PID) Intel Number UCS-CPU-X5687 A01-X0115 A01-X0100 A01-X0117 A01-X0102 A01-X0105 A01-X0109 A01-X0120 UCS-CPU-E5645 A01-X0111 A01-X0106 X5687 X5690 X5680 X5675 X5670 X5650 E5640 E5649 E5645 E5620 L5640 Clock Freq (GHz) 3.60...-MHz DIMMs with an E5620 (which can support up to 1066-MHz DIMMs), the DIMMS will be clocked at the lower speed of 1066 MHz. 8 Cisco UCS B200 M2 Blade Server For example: Selecting lower-speed DIMMs: If you use an X5650 CPU (which can support up to 1333-MHz DIMMs) with...
Table 3 Available Intel CPUs: Xeon Westmere-EP x56xx Family Product ID (PID) Intel Number UCS-CPU-X5687 A01-X0115 A01-X0100 A01-X0117 A01-X0102 A01-X0105 A01-X0109 A01-X0120 UCS-CPU-E5645 A01-X0111 A01-X0106 X5687 X5690 X5680 X5675 X5670 X5650 E5640 E5649 E5645 E5620 L5640 Clock Freq (GHz) 3.60...-MHz DIMMs with an E5620 (which can support up to 1066-MHz DIMMs), the DIMMS will be clocked at the lower speed of 1066 MHz. 8 Cisco UCS B200 M2 Blade Server For example: Selecting lower-speed DIMMs: If you use an X5650 CPU (which can support up to 1333-MHz DIMMs) with...
Specifications
Page 9
... selected than that shown in the tables, suboptimal performance will be clocked at the lower speed of CPU clock and DIMM clock. Cisco UCS B200 M2 Blade Server 9 Table 4 Available Intel CPUs: Xeon Nehalem x55xx Family Product ID (PID) Intel Number Clock Freq (GHz... (W) Cache Size (MB) Cores QPI Highest DDR3 DIMM Clock Support (MHz)1 N20-X00001 X5570 2.93 95 8 4 6.4 GT/s N20-X00006 X5550 2.66 95 8 4 6.4 GT/s N20-X00002 E5540 2.53 80 8 4 5.86 GT/s N20-X00003 E5520 2.26 80 8 4 5.86 GT/s N20-X00004 L5520 2.26 60 8 4 5.86 GT/s 1333 1333 1066 1066 1066...
... selected than that shown in the tables, suboptimal performance will be clocked at the lower speed of CPU clock and DIMM clock. Cisco UCS B200 M2 Blade Server 9 Table 4 Available Intel CPUs: Xeon Nehalem x55xx Family Product ID (PID) Intel Number Clock Freq (GHz... (W) Cache Size (MB) Cores QPI Highest DDR3 DIMM Clock Support (MHz)1 N20-X00001 X5570 2.93 95 8 4 6.4 GT/s N20-X00006 X5550 2.66 95 8 4 6.4 GT/s N20-X00002 E5540 2.53 80 8 4 5.86 GT/s N20-X00003 E5520 2.26 80 8 4 5.86 GT/s N20-X00004 L5520 2.26 60 8 4 5.86 GT/s 1333 1333 1066 1066 1066...
Specifications
Page 10
Operational voltage: 1.5 or 1.35 V - CONFIGURING the SERVER STEP 3 CHOOSE MEMORY Figure 3 The standard memory features are: ■ DIMMs - Ranks per channel, as shown in Figure 3. B200 M2 Memory Organization 10 Cisco UCS B200 M2 Blade Server Registered ■ DDR3 ECC registered DIMMs (RDIMMs), supporting Intel SDDC ■ Memory is organized with three memory channels per CPU, with up to two DIMMs per DIMM: 1, 2, or 4 - Clock speed: 1333 or 1066 MHz -
Operational voltage: 1.5 or 1.35 V - CONFIGURING the SERVER STEP 3 CHOOSE MEMORY Figure 3 The standard memory features are: ■ DIMMs - Ranks per channel, as shown in Figure 3. B200 M2 Memory Organization 10 Cisco UCS B200 M2 Blade Server Registered ■ DDR3 ECC registered DIMMs (RDIMMs), supporting Intel SDDC ■ Memory is organized with three memory channels per CPU, with up to two DIMMs per DIMM: 1, 2, or 4 - Clock speed: 1333 or 1066 MHz -
Specifications
Page 11
...DIMM and its mirrored DIMM. Table 5 Available DDR3 DIMMs Product ID (PID) PID Description DIMM Options UCS-MU-1X041RX-A 4GB DDR3-1333-MHz RDIMM/PC3-10600/1R/x4/dual voltage UCS-MR-1X082RX-A 8GB DDR3-1333-MHz RDIMM/PC3-10600/2R/x4/dual voltage A02-M316GB1-L 16GB DDR3...Memory mirroring option Voltage Ranks /DIMM 1.35/1.5 V 1 1.35/1.5 V 2 1.35/1.5 V 2 4GB DDR3-1333-MHz UDIMM/PC3-10600/single rank/x4/1.35v Cisco UCS B200 M2 Blade Server 11 If a memory read from the other channel. CONFIGURING the SERVER Choose DIMMs and Memory Mirroring Select the memory configuration and...
...DIMM and its mirrored DIMM. Table 5 Available DDR3 DIMMs Product ID (PID) PID Description DIMM Options UCS-MU-1X041RX-A 4GB DDR3-1333-MHz RDIMM/PC3-10600/1R/x4/dual voltage UCS-MR-1X082RX-A 8GB DDR3-1333-MHz RDIMM/PC3-10600/2R/x4/dual voltage A02-M316GB1-L 16GB DDR3...Memory mirroring option Voltage Ranks /DIMM 1.35/1.5 V 1 1.35/1.5 V 2 1.35/1.5 V 2 4GB DDR3-1333-MHz UDIMM/PC3-10600/single rank/x4/1.35v Cisco UCS B200 M2 Blade Server 11 If a memory read from the other channel. CONFIGURING the SERVER Choose DIMMs and Memory Mirroring Select the memory configuration and...
Specifications
Page 12
... the following table: Number of DIMMs 2 4 DIMM Placement in Channels (Channel C is optimized when the DIMM type and quantity are equal for both CPUs. 12 Cisco UCS B200 M2 Blade Server NOTE: System performance is not used with memory mirroring: ■ Select two or four DIMMs per CPU. CONFIGURING the SERVER Approved...
... the following table: Number of DIMMs 2 4 DIMM Placement in Channels (Channel C is optimized when the DIMM type and quantity are equal for both CPUs. 12 Cisco UCS B200 M2 Blade Server NOTE: System performance is not used with memory mirroring: ■ Select two or four DIMMs per CPU. CONFIGURING the SERVER Approved...
Specifications
Page 13
... your configuration, the server forces all DIMMs to be the same PID because you select the Memory RAS option, be located on Channel B of CPU 1. Cisco UCS B200 M2 Blade Server 13 If you have four DIMMs in Performance Mode. ■ Memory mirroring: If you have two DIMMs, they need to operate...
... your configuration, the server forces all DIMMs to be the same PID because you select the Memory RAS option, be located on Channel B of CPU 1. Cisco UCS B200 M2 Blade Server 13 If you have four DIMMs in Performance Mode. ■ Memory mirroring: If you have two DIMMs, they need to operate...
Specifications
Page 14
Table 6 Available Hot-Pluggable Sled-Mounted SSDs Product ID (PID) PID Description HDDs A03-D146GC2 A03-D300GA2 UCS-HDD300GI2F105 A03-D500GC3 A03-D600GA2 UCS-HDD900GI2F106 A03-D1TBSATA SDDs UCS-SSD100GI1F104 146 GB SAS 15K RPM SFF HDD 300 GB 6 Gb SAS 10K RPM SFF HDD 300GB SAS 15k RPM 2.5in HDD 500 GB 6 Gb... factor ■ Hot-pluggable ■ Sled-mounted Choose Drives The available drives are listed in Table 6. You cannot mix SAS and SATA drive types. 14 Cisco UCS B200 M2 Blade Server Caveats ■ You cannot mix HDD and SSD drives.
Table 6 Available Hot-Pluggable Sled-Mounted SSDs Product ID (PID) PID Description HDDs A03-D146GC2 A03-D300GA2 UCS-HDD300GI2F105 A03-D500GC3 A03-D600GA2 UCS-HDD900GI2F106 A03-D1TBSATA SDDs UCS-SSD100GI1F104 146 GB SAS 15K RPM SFF HDD 300 GB 6 Gb SAS 10K RPM SFF HDD 300GB SAS 15k RPM 2.5in HDD 500 GB 6 Gb... factor ■ Hot-pluggable ■ Sled-mounted Choose Drives The available drives are listed in Table 6. You cannot mix SAS and SATA drive types. 14 Cisco UCS B200 M2 Blade Server Caveats ■ You cannot mix HDD and SSD drives.
Specifications
Page 15
... Adapter/PCIe/2port 10Gb N20-AE0002 UCS M71KR-E Emulex Converged Network Adapter/PCIe/2port 10Gb N20-AC0002 UCS M81KR Virtual Interface Card/PCIe/2-port 10Gb N20-AQ0102 Cisco UCS CNA M72KR-Q QLogic Converged Network Adapter N20-AE0102 Cisco UCS CNA M72KR-E Emulex Converged Network Adapter N20-AI0102 Cisco UCS CNA M61KR-I Intel Converged Network Adapter Network Interface Cards (NICs) N20-AB0002 Cisco UCS NIC M51KR-B Broadcom...
... Adapter/PCIe/2port 10Gb N20-AE0002 UCS M71KR-E Emulex Converged Network Adapter/PCIe/2port 10Gb N20-AC0002 UCS M81KR Virtual Interface Card/PCIe/2-port 10Gb N20-AQ0102 Cisco UCS CNA M72KR-Q QLogic Converged Network Adapter N20-AE0102 Cisco UCS CNA M72KR-E Emulex Converged Network Adapter N20-AI0102 Cisco UCS CNA M61KR-I Intel Converged Network Adapter Network Interface Cards (NICs) N20-AB0002 Cisco UCS NIC M51KR-B Broadcom...
Specifications
Page 16
...-RS RHEL Option/High-Availability/2 Socket/1Yr Redhat Svcs Incld RHEL-RS-2S-1A-RS RHEL Option/Resilient Storage/2 Socket/1 Yr Redhat Svcs Incl 16 Cisco UCS B200 M2 Blade Server CONFIGURING the SERVER STEP 6 CHOOSE OPERATING SYSTEM Several operating systems are available from which to choose. Choose one of the operating...
...-RS RHEL Option/High-Availability/2 Socket/1Yr Redhat Svcs Incld RHEL-RS-2S-1A-RS RHEL Option/Resilient Storage/2 Socket/1 Yr Redhat Svcs Incl 16 Cisco UCS B200 M2 Blade Server CONFIGURING the SERVER STEP 6 CHOOSE OPERATING SYSTEM Several operating systems are available from which to choose. Choose one of the operating...
Specifications
Page 17
... 1 Processor, 4 Year Support VMware vSphere 5 Enterprise Plus for 1 Processor, 5 Year, Support VMware vCenter 5 Standard for 1 Processor, 1 Year, Support R VMware vCenter 5 Standard for 1 Processor, 2 Year, Support R Cisco UCS B200 M2 Blade Server 17
... 1 Processor, 4 Year Support VMware vSphere 5 Enterprise Plus for 1 Processor, 5 Year, Support VMware vCenter 5 Standard for 1 Processor, 1 Year, Support R VMware vCenter 5 Standard for 1 Processor, 2 Year, Support R Cisco UCS B200 M2 Blade Server 17
Specifications
Page 18
CONFIGURING the SERVER Table 8 Operating Systems (continued) PID Description Product ID (PID) VMW-VC5-ST-3A VMW-VC5-ST-4A VMW-VC5-ST-5A VMware vCenter 5 Standard for 1 Processor, 3 Year, Support R VMware vCenter 5 Standard for 1 Processor, 4 Year, Support R VMware vCenter 5 Standard for 1 Processor, 5 Year, Support R 18 Cisco UCS B200 M2 Blade Server
CONFIGURING the SERVER Table 8 Operating Systems (continued) PID Description Product ID (PID) VMW-VC5-ST-3A VMW-VC5-ST-4A VMW-VC5-ST-5A VMware vCenter 5 Standard for 1 Processor, 3 Year, Support R VMware vCenter 5 Standard for 1 Processor, 4 Year, Support R VMware vCenter 5 Standard for 1 Processor, 5 Year, Support R 18 Cisco UCS B200 M2 Blade Server
Specifications
Page 19
CONFIGURING the SERVER STEP 7 CHOOSE OPERATING SYSTEM MEDIA KIT Choose the optional operating system media listed in Table 9. Table 9 OS Media Product ID (PID) RHEL-6 SLES-11 MSWS-08R2-STHV-RM MSWS-08RS-ENHV-RM MSWS-08R2-DCHV-RM PID Description RHEL 6 Recovery Media Only (Multilingual) SLES 11 media only (multilingual) Windows Svr 2008 R2 ST (1-4CPU, 5CAL), Media Windows Svr 2008 R2 EN (1-8CPU, 25CAL), Media Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media Cisco UCS B200 M2 Blade Server 19
CONFIGURING the SERVER STEP 7 CHOOSE OPERATING SYSTEM MEDIA KIT Choose the optional operating system media listed in Table 9. Table 9 OS Media Product ID (PID) RHEL-6 SLES-11 MSWS-08R2-STHV-RM MSWS-08RS-ENHV-RM MSWS-08R2-DCHV-RM PID Description RHEL 6 Recovery Media Only (Multilingual) SLES 11 media only (multilingual) Windows Svr 2008 R2 ST (1-4CPU, 5CAL), Media Windows Svr 2008 R2 EN (1-8CPU, 25CAL), Media Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media Cisco UCS B200 M2 Blade Server 19
Specifications
Page 20
... of value-added software listed in Table 9.s Table 10 Value Added Software Product ID (PID) PID Description N1K-CSK9-UCS-404 BMC-012 BMC-SE-4C BMC-SE-6C BMC-SE-8C BMC-SE-10C BMC-AE-4C BMC-AE-6C ...BMC-AE-8C BMC-AE-10C Cisco Nexus 1000V VSM Virtual Appliance Software BMC BPPM Per Server BMC BladeLogic Standard Edition, 4 Cores, Support Required BMC BladeLogic Standard...Support Required BMC BladeLogic Advanced Edition, 8 Cores, Support Required BMC BladeLogic Advanced Edition, 10 Cores, Support Required 20 Cisco UCS B200 M2 Blade Server
... of value-added software listed in Table 9.s Table 10 Value Added Software Product ID (PID) PID Description N1K-CSK9-UCS-404 BMC-012 BMC-SE-4C BMC-SE-6C BMC-SE-8C BMC-SE-10C BMC-AE-4C BMC-AE-6C ...BMC-AE-8C BMC-AE-10C Cisco Nexus 1000V VSM Virtual Appliance Software BMC BPPM Per Server BMC BladeLogic Standard Edition, 4 Cores, Support Required BMC BladeLogic Standard...Support Required BMC BladeLogic Advanced Edition, 8 Cores, Support Required BMC BladeLogic Advanced Edition, 10 Cores, Support Required 20 Cisco UCS B200 M2 Blade Server