Specifications
Page 1
Spec Sheet Cisco UCS B200 M2 Blade Server CISCO SYSTEMS 170 WEST TASMAN DR. SAN JOSE, CA, 95134 WWW.CISCO.COM PUBLICATION HISTORY REV A.1 MARCH 9, 2012
Spec Sheet Cisco UCS B200 M2 Blade Server CISCO SYSTEMS 170 WEST TASMAN DR. SAN JOSE, CA, 95134 WWW.CISCO.COM PUBLICATION HISTORY REV A.1 MARCH 9, 2012
Specifications
Page 2
... 25 SUPPLEMENTAL MATERIAL 26 Motherboard 26 DIMM and CPU Layout 26 Memory Population Recommendations 27 TECHNICAL SPECIFICATIONS 29 Dimensions and Weight 29 Power Specifications 29 Cisco UCS B200 M2 Blade Server 2
... 25 SUPPLEMENTAL MATERIAL 26 Motherboard 26 DIMM and CPU Layout 26 Memory Population Recommendations 27 TECHNICAL SPECIFICATIONS 29 Dimensions and Weight 29 Power Specifications 29 Cisco UCS B200 M2 Blade Server 2
Specifications
Page 3
Figure 1 Cisco UCS B200 M2 Blade Server Cisco UCS B200 M2 Blade Server 3 Up to two solid-state disk (SSD) drives or hard disk drives (HDDs). OVERVIEW OVERVIEW The Cisco UCS B200 M2 Blade Server (Figure 1) Server is a two-socket, half-width blade server, using Intel's Xeon 5500 and 5600 Series processors with 12 DIMM slots, one mezzanine slot to hold an adapter card, and up to eight half-width blade servers can be accommodated in the Cisco UCS 5108 Blade Server Chassis.
Figure 1 Cisco UCS B200 M2 Blade Server Cisco UCS B200 M2 Blade Server 3 Up to two solid-state disk (SSD) drives or hard disk drives (HDDs). OVERVIEW OVERVIEW The Cisco UCS B200 M2 Blade Server (Figure 1) Server is a two-socket, half-width blade server, using Intel's Xeon 5500 and 5600 Series processors with 12 DIMM slots, one mezzanine slot to hold an adapter card, and up to eight half-width blade servers can be accommodated in the Cisco UCS 5108 Blade Server Chassis.
Specifications
Page 4
...the KVM device included in the chassis accessory kit that plugs into the console connector, see ORDER OPTIONAL KVM CABLE on page 25. 4 Cisco UCS B200 M2 Blade Server Figure 2 Chassis Front View 4 5 1 2 3 6 78 9 10 11 1 Asset tag (you can remove this tag and... 7 Network link status LED add your own) 2 Blade ejector handle 8 Blade health LED 3 Blade ejector handle captive screw 9 Console connector1 4 Drive bay 1 (hot pluggable) 10 Reset button access 5 Drive bay 2 (hot pluggable) 11 Beaconing LED...
...the KVM device included in the chassis accessory kit that plugs into the console connector, see ORDER OPTIONAL KVM CABLE on page 25. 4 Cisco UCS B200 M2 Blade Server Figure 2 Chassis Front View 4 5 1 2 3 6 78 9 10 11 1 Asset tag (you can remove this tag and... 7 Network link status LED add your own) 2 Blade ejector handle 8 Blade health LED 3 Blade ejector handle captive screw 9 Console connector1 4 Drive bay 1 (hot pluggable) 10 Reset button access 5 Drive bay 2 (hot pluggable) 11 Beaconing LED...
Specifications
Page 5
.../Feature Chassis CPU Chipset Memory Expansion slots Storage controller Internal storage devices Video Interfaces Power subsystem Fans Integrated management processor Description The B200 M2 Blade Server mounts in Cisco Integrated Management Controller (CIMC) GUI or CLI interface enables you to two optional front-accessible, hot-pluggable 2.5-inch small form factor (SFF) ...SAS or SATA solid-state disk (SSD) or hard disk (HDD) drives. The first 8 MB of the base server. Cisco UCS B200 M2 Blade Server 5 The server CIMC chip includes a Matrox G200 core.
.../Feature Chassis CPU Chipset Memory Expansion slots Storage controller Internal storage devices Video Interfaces Power subsystem Fans Integrated management processor Description The B200 M2 Blade Server mounts in Cisco Integrated Management Controller (CIMC) GUI or CLI interface enables you to two optional front-accessible, hot-pluggable 2.5-inch small form factor (SFF) ...SAS or SATA solid-state disk (SSD) or hard disk (HDD) drives. The first 8 MB of the base server. Cisco UCS B200 M2 Blade Server 5 The server CIMC chip includes a Matrox G200 core.
Specifications
Page 6
CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS B200 Blade Server: ■ STEP 1 VERIFY BASE SKU, page 7 ■ STEP 2 CHOOSE CPU(S), page 8 ■ STEP 3 CHOOSE MEMORY, page 10 ■ STEP 4 CHOOSE HARD DISK DRIVES or ... 7 CHOOSE OPERATING SYSTEM MEDIA KIT, page 19 ■ STEP 8 CHOOSE OPTIONAL VALUE-ADDED SOFTWARE, page 20 ■ STEP 9 CHOOSE SERVICE and SUPPORT LEVEL, page 21 6 Cisco UCS B200 M2 Blade Server
CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS B200 Blade Server: ■ STEP 1 VERIFY BASE SKU, page 7 ■ STEP 2 CHOOSE CPU(S), page 8 ■ STEP 3 CHOOSE MEMORY, page 10 ■ STEP 4 CHOOSE HARD DISK DRIVES or ... 7 CHOOSE OPERATING SYSTEM MEDIA KIT, page 19 ■ STEP 8 CHOOSE OPTIONAL VALUE-ADDED SOFTWARE, page 20 ■ STEP 9 CHOOSE SERVICE and SUPPORT LEVEL, page 21 6 Cisco UCS B200 M2 Blade Server
Specifications
Page 7
Mezzanine adapter card NOTE: Use the steps on the following pages to configure the server with the components that you want to include. CPUs - Table 2 PID of the base server as shown in Table 2. Disk drives - Memory - CONFIGURING the SERVER STEP 1 VERIFY BASE SKU Verify the product ID (PID) of the Base B200 M2 Blade Server Product ID (PID) Description N20-B6625-1-UPG UCS B200 M2 Blade Server w/o CPU, memory, HDD, mezzanine The N20-B6625-1-UPG B200 M2 base server: ■ Includes: - KVM cable ■ Does not include: - Cisco UCS B200 M2 Blade Server 7
Mezzanine adapter card NOTE: Use the steps on the following pages to configure the server with the components that you want to include. CPUs - Table 2 PID of the base server as shown in Table 2. Disk drives - Memory - CONFIGURING the SERVER STEP 1 VERIFY BASE SKU Verify the product ID (PID) of the Base B200 M2 Blade Server Product ID (PID) Description N20-B6625-1-UPG UCS B200 M2 Blade Server w/o CPU, memory, HDD, mezzanine The N20-B6625-1-UPG B200 M2 base server: ■ Includes: - KVM cable ■ Does not include: - Cisco UCS B200 M2 Blade Server 7
Specifications
Page 8
... with an E5620 (which can support up to 1066-MHz DIMMs), the DIMMS will be clocked at the lower speed of 1066 MHz. 8 Cisco UCS B200 M2 Blade Server For example: Selecting lower-speed DIMMs: If you use an X5650 CPU (which can support up to 1333-MHz DIMMs) with 1066-MHz...
... with an E5620 (which can support up to 1066-MHz DIMMs), the DIMMS will be clocked at the lower speed of 1066 MHz. 8 Cisco UCS B200 M2 Blade Server For example: Selecting lower-speed DIMMs: If you use an X5650 CPU (which can support up to 1333-MHz DIMMs) with 1066-MHz...
Specifications
Page 9
... (W) Cache Size (MB) Cores QPI Highest DDR3 DIMM Clock Support (MHz)1 N20-X00001 X5570 2.93 95 8 4 6.4 GT/s N20-X00006 X5550 2.66 95 8 4 6.4 GT/s N20-X00002 E5540 2.53 80 8 4 5.86 GT/s N20-X00003 E5520 2.26 80 8 4 5.86 GT/s N20-X00004 L5520 2.26 60 8 4 5.86 GT/s 1333 1333 1066 1066 1066... Notes . . . 1. If higher or lower speed DIMMs are lower or higher than what is shown in Table 4. Caveats ■ You must select either one of the rows of 1066 MHz. Cisco UCS B200 M2 Blade...
... (W) Cache Size (MB) Cores QPI Highest DDR3 DIMM Clock Support (MHz)1 N20-X00001 X5570 2.93 95 8 4 6.4 GT/s N20-X00006 X5550 2.66 95 8 4 6.4 GT/s N20-X00002 E5540 2.53 80 8 4 5.86 GT/s N20-X00003 E5520 2.26 80 8 4 5.86 GT/s N20-X00004 L5520 2.26 60 8 4 5.86 GT/s 1333 1333 1066 1066 1066... Notes . . . 1. If higher or lower speed DIMMs are lower or higher than what is shown in Table 4. Caveats ■ You must select either one of the rows of 1066 MHz. Cisco UCS B200 M2 Blade...
Specifications
Page 10
Ranks per channel, as shown in Figure 3. B200 M2 Memory Organization 10 Cisco UCS B200 M2 Blade Server Clock speed: 1333 or 1066 MHz - Operational voltage: 1.5 or 1.35 V - CONFIGURING the SERVER STEP 3 CHOOSE MEMORY Figure 3 The standard memory features are: ■ DIMMs - Registered ■ DDR3 ECC registered DIMMs (RDIMMs), supporting Intel SDDC ■ Memory is organized with three memory channels per CPU, with up to two DIMMs per DIMM: 1, 2, or 4 -
Ranks per channel, as shown in Figure 3. B200 M2 Memory Organization 10 Cisco UCS B200 M2 Blade Server Clock speed: 1333 or 1066 MHz - Operational voltage: 1.5 or 1.35 V - CONFIGURING the SERVER STEP 3 CHOOSE MEMORY Figure 3 The standard memory features are: ■ DIMMs - Registered ■ DDR3 ECC registered DIMMs (RDIMMs), supporting Intel SDDC ■ Memory is organized with three memory channels per CPU, with up to two DIMMs per DIMM: 1, 2, or 4 -
Specifications
Page 11
... Option N01-MMIRROR Memory mirroring option Voltage Ranks /DIMM 1.35/1.5 V 1 1.35/1.5 V 2 1.35/1.5 V 2 4GB DDR3-1333-MHz UDIMM/PC3-10600/single rank/x4/1.35v Cisco UCS B200 M2 Blade Server 11 If a memory read from the other channel. The available memory DIMMs are listed in Table 5. A transient or soft error in exactly the...
... Option N01-MMIRROR Memory mirroring option Voltage Ranks /DIMM 1.35/1.5 V 1 1.35/1.5 V 2 1.35/1.5 V 2 4GB DDR3-1333-MHz UDIMM/PC3-10600/single rank/x4/1.35v Cisco UCS B200 M2 Blade Server 11 If a memory read from the other channel. The available memory DIMMs are listed in Table 5. A transient or soft error in exactly the...
Specifications
Page 12
... will be placed by the factory as shown in Channels (Channel C is optimized when the DIMM type and quantity are equal for both CPUs. 12 Cisco UCS B200 M2 Blade Server
... will be placed by the factory as shown in Channels (Channel C is optimized when the DIMM type and quantity are equal for both CPUs. 12 Cisco UCS B200 M2 Blade Server
Specifications
Page 13
In this case, two DIMMS would go into effect on Channel D of CPU 2. Cisco UCS B200 M2 Blade Server 13 NOTE: For memory mirroring, DIMM pairing across buses must be located on page 26. If you have four DIMMs in a 2-CPU system, for ...
In this case, two DIMMS would go into effect on Channel D of CPU 2. Cisco UCS B200 M2 Blade Server 13 NOTE: For memory mirroring, DIMM pairing across buses must be located on page 26. If you have four DIMMs in a 2-CPU system, for ...
Specifications
Page 14
... drives are listed in Table 6. Caveats ■ You cannot mix HDD and SSD drives. You cannot mix SAS and SATA drive types. 14 Cisco UCS B200 M2 Blade Server Table 6 Available Hot-Pluggable Sled-Mounted SSDs Product ID (PID) PID Description HDDs A03-D146GC2 A03-D300GA2 UCS-HDD300GI2F105 A03-D500GC3 A03-D600GA2...
... drives are listed in Table 6. Caveats ■ You cannot mix HDD and SSD drives. You cannot mix SAS and SATA drive types. 14 Cisco UCS B200 M2 Blade Server Table 6 Available Hot-Pluggable Sled-Mounted SSDs Product ID (PID) PID Description HDDs A03-D146GC2 A03-D300GA2 UCS-HDD300GI2F105 A03-D500GC3 A03-D600GA2...
Specifications
Page 15
...N20-AC0002 UCS M81KR Virtual Interface Card/PCIe/2-port 10Gb N20-AQ0102 Cisco UCS CNA M72KR-Q QLogic Converged Network Adapter N20-AE0102 Cisco UCS CNA M72KR-E Emulex Converged Network Adapter N20-AI0102 Cisco UCS CNA M61KR-I Intel Converged Network Adapter Network Interface Cards (NICs) N20-AB0002 Cisco ...cards you have selected, please check the Hardware Compatibility List at this URL: http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html Cisco UCS B200 M2 Blade Server 15 CONFIGURING the SERVER STEP 5 CHOOSE A PCIe MEZZANINE CARD The standard PCIe card ...
...N20-AC0002 UCS M81KR Virtual Interface Card/PCIe/2-port 10Gb N20-AQ0102 Cisco UCS CNA M72KR-Q QLogic Converged Network Adapter N20-AE0102 Cisco UCS CNA M72KR-E Emulex Converged Network Adapter N20-AI0102 Cisco UCS CNA M61KR-I Intel Converged Network Adapter Network Interface Cards (NICs) N20-AB0002 Cisco ...cards you have selected, please check the Hardware Compatibility List at this URL: http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html Cisco UCS B200 M2 Blade Server 15 CONFIGURING the SERVER STEP 5 CHOOSE A PCIe MEZZANINE CARD The standard PCIe card ...
Specifications
Page 16
...-RS RHEL Option/High-Availability/2 Socket/1Yr Redhat Svcs Incld RHEL-RS-2S-1A-RS RHEL Option/Resilient Storage/2 Socket/1 Yr Redhat Svcs Incl 16 Cisco UCS B200 M2 Blade Server Choose one of the operating systems listed in Table 8.
...-RS RHEL Option/High-Availability/2 Socket/1Yr Redhat Svcs Incld RHEL-RS-2S-1A-RS RHEL Option/Resilient Storage/2 Socket/1 Yr Redhat Svcs Incl 16 Cisco UCS B200 M2 Blade Server Choose one of the operating systems listed in Table 8.
Specifications
Page 17
... 1 Processor, 4 Year Support VMware vSphere 5 Enterprise Plus for 1 Processor, 5 Year, Support VMware vCenter 5 Standard for 1 Processor, 1 Year, Support R VMware vCenter 5 Standard for 1 Processor, 2 Year, Support R Cisco UCS B200 M2 Blade Server 17
... 1 Processor, 4 Year Support VMware vSphere 5 Enterprise Plus for 1 Processor, 5 Year, Support VMware vCenter 5 Standard for 1 Processor, 1 Year, Support R VMware vCenter 5 Standard for 1 Processor, 2 Year, Support R Cisco UCS B200 M2 Blade Server 17
Specifications
Page 18
CONFIGURING the SERVER Table 8 Operating Systems (continued) PID Description Product ID (PID) VMW-VC5-ST-3A VMW-VC5-ST-4A VMW-VC5-ST-5A VMware vCenter 5 Standard for 1 Processor, 3 Year, Support R VMware vCenter 5 Standard for 1 Processor, 4 Year, Support R VMware vCenter 5 Standard for 1 Processor, 5 Year, Support R 18 Cisco UCS B200 M2 Blade Server
CONFIGURING the SERVER Table 8 Operating Systems (continued) PID Description Product ID (PID) VMW-VC5-ST-3A VMW-VC5-ST-4A VMW-VC5-ST-5A VMware vCenter 5 Standard for 1 Processor, 3 Year, Support R VMware vCenter 5 Standard for 1 Processor, 4 Year, Support R VMware vCenter 5 Standard for 1 Processor, 5 Year, Support R 18 Cisco UCS B200 M2 Blade Server
Specifications
Page 19
Table 9 OS Media Product ID (PID) RHEL-6 SLES-11 MSWS-08R2-STHV-RM MSWS-08RS-ENHV-RM MSWS-08R2-DCHV-RM PID Description RHEL 6 Recovery Media Only (Multilingual) SLES 11 media only (multilingual) Windows Svr 2008 R2 ST (1-4CPU, 5CAL), Media Windows Svr 2008 R2 EN (1-8CPU, 25CAL), Media Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media Cisco UCS B200 M2 Blade Server 19 CONFIGURING the SERVER STEP 7 CHOOSE OPERATING SYSTEM MEDIA KIT Choose the optional operating system media listed in Table 9.
Table 9 OS Media Product ID (PID) RHEL-6 SLES-11 MSWS-08R2-STHV-RM MSWS-08RS-ENHV-RM MSWS-08R2-DCHV-RM PID Description RHEL 6 Recovery Media Only (Multilingual) SLES 11 media only (multilingual) Windows Svr 2008 R2 ST (1-4CPU, 5CAL), Media Windows Svr 2008 R2 EN (1-8CPU, 25CAL), Media Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media Cisco UCS B200 M2 Blade Server 19 CONFIGURING the SERVER STEP 7 CHOOSE OPERATING SYSTEM MEDIA KIT Choose the optional operating system media listed in Table 9.
Specifications
Page 20
...-012 BMC-SE-4C BMC-SE-6C BMC-SE-8C BMC-SE-10C BMC-AE-4C BMC-AE-6C BMC-AE-8C BMC-AE-10C Cisco Nexus 1000V VSM Virtual Appliance Software BMC BPPM Per Server BMC BladeLogic Standard Edition, 4 Cores, Support Required BMC BladeLogic Standard Edition, 6 Cores, Support Required BMC..., Support Required BMC BladeLogic Advanced Edition, 6 Cores, Support Required BMC BladeLogic Advanced Edition, 8 Cores, Support Required BMC BladeLogic Advanced Edition, 10 Cores, Support Required 20 Cisco UCS B200 M2 Blade Server
...-012 BMC-SE-4C BMC-SE-6C BMC-SE-8C BMC-SE-10C BMC-AE-4C BMC-AE-6C BMC-AE-8C BMC-AE-10C Cisco Nexus 1000V VSM Virtual Appliance Software BMC BPPM Per Server BMC BladeLogic Standard Edition, 4 Cores, Support Required BMC BladeLogic Standard Edition, 6 Cores, Support Required BMC..., Support Required BMC BladeLogic Advanced Edition, 6 Cores, Support Required BMC BladeLogic Advanced Edition, 8 Cores, Support Required BMC BladeLogic Advanced Edition, 10 Cores, Support Required 20 Cisco UCS B200 M2 Blade Server