Realis Command Codes - Page 4

... ground Control Mode The SX50 has two control modes: LOCAL and REMOTE. Double-byte characters and single-byte characters are set by the REMOTE and LOCAL commands. The two modes are not distinguished. No procedure None None Not supported Tc Character interval: 10 ms Tr Command/response interval: 10 s Connection Specifications Item Connection system...
Realis Command Codes - Page 15

... command. 4 0004 5 0005 e INVALID_FORMAT e NOT_POWER_SUPPLIED The command format is not being updated. Power is incorrect. Use the correct parameter(s). 8 000B 9 - Resend the command....set to input, and then select the input again. 16 1002 e NO_LOGO_CAPTURED Processing cannot be executed with the current input signal. Error List Item Code TYPE Error character string Error ...
Realis Command Codes - Page 17

...manual for input signal setting ● ● Input signal select AUTO SEL ● ● Input signal select PC not selected ------------ ● ● Screen settings...9679; ● ● ● ● ● Terminal setting Power management Beep Key lock Password on/off Password text Remote control Language Menu category item Last spotlight Spotlight OSD position ...
Realis Command Codes - Page 20

Commands POWER Function This controls the power supply. Response An "i:OK" is returned after setting is in the controlled state (off △ ○ Lit→standby ○... can be viewed with the GET command. Mode Control Setting Reference Parameter Parameter Meaning ON Power ON OFF Power OFF ID The RANGE command can be set at that time. POWER Command Responses by " Example...
Realis Command Codes - Page 21

... *Commands are indicated by ">", and responses are indicated by " Description This selects the input. (1) This command is identical to obtain the parameters that can be set for the TERMINAL command, "A-RGB2" and "COMP" cannot be selected! ('e:1001 TERMINAL_OUT' is successful. Commands INPUT Function Input select Parameter Parameter Meaning D-RGB D-RGB A-RGB1...
Realis Command Codes - Page 22

...This executes Auto PC. (1) This command is successful. Commands AUTOPC Function Auto PC Mode Control Setting Reference Parameter None Response An "i:OK" is returned after control is identical to pressing the "...control or front panel. (2) Execution of this command may modify the following setting values. • Total number of dots • Tracking • Horizontal/Vertical position •...
Realis Command Codes - Page 23

... total number of dots is identical to the [Tracking] function under [Input signal settings] in the [Display settings] menu. (2) The GET command can be used to obtain the current total number...indicated by " Commands DOTS Function Total number of dots adjustment Mode Control Setting Reference Parameter Number of dots The RANGE command can be used to obtain the parameter range that can be...
Realis Command Codes - Page 24

... are indicated by ">", and responses are indicated by " Reference > GET TRACK or ?TRACK < g:TRACK=21 This retrieves the tracking adjustment setting value. Number Response An "i:OK" is returned after setting is set at that time. Description This is used for adjustment when tracking (synchronization) is out of sync and the screen flickers. (1) This...
Realis Command Codes - Page 25

...Number Response An 'i:OK' is returned after setting is identical to the Horizontal position and Vertical position functions under the [Input signal settings] in the [Display settings] menu. (2) The GET command can be.... Commands HPOS VPOS Function Horizontal and vertical position adjustment Mode Control Setting Reference Parameter Adjustment value The RANGE command can be used to retrieve...
Realis Command Codes - Page 26

... resolution (number of dots) on the screen. (1) This command is successful. Number Response An 'i:OK' is returned after setting is identical to the Horizontal pixels and Vertical pixels functions under the Input signal settings in the Display settings menu. (2) The GET command can be used to obtain the parameter range that can be...
Realis Command Codes - Page 27

... 480p 575i Includes 288p (PAL non-interlaced signal) 480i Includes 240p (NTSC non-interlaced signal) UNKNOWN No-color, 1080p, and other signals Example Setting > SEL=AUTO < i:OK This sets the input signal selection to retrieve the current input signal. Reference > GET SEL or ?SEL < g:SEL=575p This retrieves the input signal. *Commands...
Realis Command Codes - Page 28

... GET command can be used to obtain the parameters that can be set at that time. Example Setting > ASPECT=WIDE > i:OK This sets the screen size to retrieve the current screen display mode. Description This sets the screen sizes. (1) The final screen settings are indicated by ">", and responses are retained even when the power is...
Realis Command Codes - Page 30

... (Min, Max) > RANGE BRI < r:BRI=N,-20,20 *Commands are indicated by ">", and responses are indicated by " Number Description This sets the screen brightness. (1) This command is successful. Example Setting > BRI=10 < i:OK This sets the brightness to the Brightness function in the Image adj. Reference > GET BRI or ?BRI < g:BRI=10 This retrieves...
Realis Command Codes - Page 31

... image mode. (3) The GET command can be used to retrieve the current contrast. Example Setting > CONT=3 < i:OK This sets the contrast to the Contrast function in the Image adj. Commands CONT Function Contrast setting Mode Control Setting Reference Parameter Setting value (-20 to 20) The RANGE command can be used to obtain the parameter range...
Realis Command Codes - Page 58

Commands RC Function Remote control operation emulate Mode Control Setting Reference Parameter The key assignments for controlling the projector. (1) It can only be executed. It... NOSHOW MUTE MUTE P-TIMER P_TIMER DZOOM + DZOOM_P DZOOM_M DZOOM_M SPOT SPOT *Use the application to Special mode (Service mode) Example Setting > RC POWER < i:Ok ※Commands are indicated by "

Canon REALiS LCOS SX50 Reviews

Do you have an experience with the Canon REALiS LCOS SX50 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Canon yet.

Ask a New Question
Use the box below to post a new question about Canon REALiS LCOS SX50.
Manuals / Documents
Download any of our Canon REALiS LCOS SX50 manuals for free!

We have the following 1 documents available for the Canon REALiS LCOS SX50:
  • Realis Command Codes

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Canon Manuals

Find free Canon REALiS LCOS SX50 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Canon Reviews

View thousands of Canon REALiS LCOS SX50 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Canon customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Canon customer service rankings, employee comments and much more from our sister site.

Canon Recalls

Find comprehensive Canon recall information updated hourly on RecallOwl.com.