109-L Temperature Probe
Page 7
... and the correct lengths of cable are found at the connection end of LoggerNet, PC200W, PC400, or RTDAQ software. 2. Model 109 Temperature Probe 1. Introduction The 109 Temperature Probe uses a thermistor to Campbell Scientific. 4. Quickstart Short Cut is usually found on the desktop of the shipment. Install Short Cut by clicking on this icon. 1 Model...
... and the correct lengths of cable are found at the connection end of LoggerNet, PC200W, PC400, or RTDAQ software. 2. Model 109 Temperature Probe 1. Introduction The 109 Temperature Probe uses a thermistor to Campbell Scientific. 4. Quickstart Short Cut is usually found on the desktop of the shipment. Install Short Cut by clicking on this icon. 1 Model...
109-L Temperature Probe
Page 10
... Measures air, soil, or water temperature • Compatible with AM16/32-series multiplexers • Easy to mount the 109 and limit solar radiation loading. Also compatible with Campbell Scientific CRBasic dataloggers CR200(X) series, CR800 series, CR1000, CR3000, and CR5000. See Specifications for a complete list of applications.... in Air: Between 30 and 60 s in a wind speed of a thermistor encapsulated in an epoxy-filled aluminum housing. Model 109 Temperature Probe Cut Help, which is accessed by clicking on your PC, and the PC to datalogger connection is active, you can...
... Measures air, soil, or water temperature • Compatible with AM16/32-series multiplexers • Easy to mount the 109 and limit solar radiation loading. Also compatible with Campbell Scientific CRBasic dataloggers CR200(X) series, CR800 series, CR1000, CR3000, and CR5000. See Specifications for a complete list of applications.... in Air: Between 30 and 60 s in a wind speed of a thermistor encapsulated in an epoxy-filled aluminum housing. Model 109 Temperature Probe Cut Help, which is accessed by clicking on your PC, and the PC to datalogger connection is active, you can...
109-L Temperature Probe
Page 17
... 2500 mV 5000 mV Result Vs/Vx Vs/Vx Scaling ln(Rs) by 1E-3 ln(Rs) by Campbell Scientific dataloggers. With reference to the previous FIGURE 8-1, 109 thermistor probe schematic, a precise excitation voltage is applied at the Vx line and the voltage drop across the...Polynomial (P55)) Steinhart-Hart (use Polynomial (P55)) 11 The ratio of measured voltage (Vs) to temperature. Model 109 Temperature Probe 8.2 Measurement and Output Linearization Campbell Scientific dataloggers measure the 109 probe thermistor and convert the result to excitation voltage (Vx) is measured at the Vs line.
... 2500 mV 5000 mV Result Vs/Vx Vs/Vx Scaling ln(Rs) by 1E-3 ln(Rs) by Campbell Scientific dataloggers. With reference to the previous FIGURE 8-1, 109 thermistor probe schematic, a precise excitation voltage is applied at the Vx line and the voltage drop across the...Polynomial (P55)) Steinhart-Hart (use Polynomial (P55)) 11 The ratio of measured voltage (Vs) to temperature. Model 109 Temperature Probe 8.2 Measurement and Output Linearization Campbell Scientific dataloggers measure the 109 probe thermistor and convert the result to excitation voltage (Vx) is measured at the Vs line.
109-L Temperature Probe
Page 24
More adaptation will be used with any datalogger program. ;{CR10X} ;Program measures one 109 temperature probe once a second ;and stores the average temperature every 60 minutes. ;Wiring Diagram ;109SS Probe ; ; Contact a Campbell Scientific application engineer for 60 minute averages DataTable(Table1,True,-1) DataInterval(0,10,Min,10) Average(1,T109_C,FP2,False) EndTable 'Main Program BeginProg...
More adaptation will be used with any datalogger program. ;{CR10X} ;Program measures one 109 temperature probe once a second ;and stores the average temperature every 60 minutes. ;Wiring Diagram ;109SS Probe ; ; Contact a Campbell Scientific application engineer for 60 minute averages DataTable(Table1,True,-1) DataInterval(0,10,Min,10) Average(1,T109_C,FP2,False) EndTable 'Main Program BeginProg...