User Manual - Page 4
... end-users to monitor their UPS anywhere, anytime, by simply utilizing their equipment from any power problems.
Bulldog Plus features:
1.Graceful operating system shutdown 2.Schedule test, shutdown/restart UPS, turn on the Internet, Bulldog Plus also supports HTTP protocol. Bulldog Plus allows for network management protocol (SNMP and DMI). To make use...
User Manual - Page 5
... Module (Bulldog Plus Service, file name: upsd...Belkin Components
5 Notice: Some OS may require "-" before running one file, YourUnix.tar, in the directory /usr/local/bulldog or the user specified directory.
Bulldog Plus Installation System Requirements:
1. Tar the file with the UPS. Follow the instructions from the install program. 7. Bulldog Plus Setup:
1. After installation...
User Manual - Page 6
You can also run Bulldog Plus Service manually by typing the command ./upsd in the installation directory. To stop Bulldog Plus Service, type the command ./upsd stop in the installation directory. Bulldog Plus Service
Bulldog Plus Service, which runs in the background, is a daemon process when the system starts up. Belkin Components
6
User Manual - Page 8
...the Master unit via a TCP/IP network. Shutting down workstations pres erves battery power for each different computer. When a power event occurs, Master (Bulldog Plus Service) gets the information and then ...to the Salve(s) (Bulldog Plus Service). Belkin Components
8 For example: When power fails, the file server and mail server won't shutdown until the UPS battery is low but is comprised of...
User Manual - Page 9
... Monitor will provide a list of the searched hosts in the combo box. Belkin Components
9 Remote Hosts menu to monitor Local host and Remote hosts. Remote Monitor and Control: Bulldog Plus Monitor. You can also input the remote host IP address from the View -
Bulldog Plus Monitor has the ability to establish the connection...
User Manual - Page 11
...2000 is by using the Internet Browser. Belkin Components
11
Launch the Microsoft Internet Explorer or Netscape Communicator, type the IP address in the URL and press enter you assigned.... Another method for remote monitoring with other WEB server programs. If the port number is not 80 you have to prevent conflict with Bulldog Plus Service...
User Manual - Page 17
... UPS Test Date/Time: The date of a computer, that runs Bulldog Plus Service. Local Host IP: IP address of the next user-initiated UPS self test.
Port names are different from System->Configuration->UPS->Schedule.
Setting from System->Configuration->UPS->Schedule. Remote Host IP: The host, that runs Bulldog Plus Monitor. Next UPS Shutdown Date/Time...
User Manual - Page 30
... output power is higher than the assigned value,
the UPS will switch to backup. Belkin Components
30 Transfer Voltage: Change the low transfer voltage and high transfer voltage. Low Transfer Voltage: When utility power voltage is supplied from battery. This function lets your UPS suit the local power environment. Voltage Sensitivity
Voltage...
User Manual - Page 32
... it is a Slave.
The Master will show a disconnected message. Network Menu Network :
Set Password:
Set the Bulldog Plus Service password. Master: Configure the Bulldog Plus Service to be a Slave. Belkin Components
32 Master IP Address: When Bulldog Plus Service becomes a Slave you must
assign the Master IP address such that the Slave can connect to the Master host and obtain the UPS...
User Manual - Page 33
..." command under MS-DOS prompt to see the remote host's physical address. Belkin Components
33 Or, input the "arp -a" command to get the network card physical address of the remote host. Your network card must give the IP address and the network hardware address (MAC address) of the local host. b.
a.
Remote Wakeup Remote Wakeup:
To wake up...
User Manual - Page 35
...UPS is operating on Novell NetWare operating system, all settings in this SNMP configuring dialog will soon be exhausted
6 INFORMATION: The UPS has returned
from a low battery condition
7 INFORMATION: Loading percent
of the UPS over ... SYS:\etc\Traptarg.cfg directly.
load
Belkin Components
35
SNMP (cont.)
If the Bulldog Plus Service you are low
and will not take effect.
User Manual - Page 39
...UPS hardware user's manual. UPS Audible Alarm...battery in 10 seconds.
Control (cont.)
a. b. Turn Receptacle Relay Off: Turn the receptacle relay off the outlet group.
Belkin Components
39 Select a Receptacle Relay: Select a receptacle relay.
Select a Receptacle Relay: Select a receptacle relay. Cancel Test: This menu allows you to obtain the UPS alarm status. Delay: Set...
User Manual - Page 44
... connect to the IP address that you want to connect and press the Connect button to the WAN. About: Bulldog Plus version and copyright. a. Connect to this IP address: Bulldog Plus will be listed in the LAN. c.
Belkin Components
44 Remote Hosts
Remote Hosts: Detect the hosts which running the Bulldog Plus Service in the Search...
User Manual - Page 45
... time of the UPS internal code. Scroll: UPS data graph.
Rating Current: The UPS rating current. Belkin Components
45 Diagram: Indicate the UPS current flow. Main
UPS Health: 3 levels: Green, yellow and red. Firmware Version: Indicating the version status of the schedule, battery replacement date and countdown time. AC Source: Normal, battery or byp ass. Tree...