User Guide
Page 18
Chapter 3: About Your RAID Controller ● 18 About the Adaptec 3085 The Adaptec 3085 is a SAS RAID controller with these features: Diagnostic Activity Board Power Supply LEDs LEDs Drive Activity LED connectors for CN1/CN0 Alarm connector Mode 0 Flash connector CN1 CN0 2 external SAS connectors Mounting bracket PCIe x8 connector...Onboard speaker Audible alarm Battery Backup Module Low-profile MD2 PCIe x8 2.5 Gb/s 8 256 MB DDR2 Two SAS x4 (SFF-8088) 0, 1, 1E, 10, 5, 5EE, 50,6, 60, JBOD Yes SATA, SATA II, SAS 8 (or up to 100 with expanders) Yes I2C and SGPIO (Serial General Purpose...
Chapter 3: About Your RAID Controller ● 18 About the Adaptec 3085 The Adaptec 3085 is a SAS RAID controller with these features: Diagnostic Activity Board Power Supply LEDs LEDs Drive Activity LED connectors for CN1/CN0 Alarm connector Mode 0 Flash connector CN1 CN0 2 external SAS connectors Mounting bracket PCIe x8 connector...Onboard speaker Audible alarm Battery Backup Module Low-profile MD2 PCIe x8 2.5 Gb/s 8 256 MB DDR2 Two SAS x4 (SFF-8088) 0, 1, 1E, 10, 5, 5EE, 50,6, 60, JBOD Yes SATA, SATA II, SAS 8 (or up to 100 with expanders) Yes I2C and SGPIO (Serial General Purpose...
User Guide
Page 21
... Your RAID Controller ● 21 About the Adaptec 31205 The Adaptec 31205 is a SAS RAID controller with these features: I2C connector for CN2 Activity LED Phys and connectors FE Aggregate LED connectors CB A I2C connector for CN1 I2C connector for CN0 CN0 Alarm connector Mode 0 Flash connector Battery connector CN1 3 internal SAS connectors ... Half-size PCIe x8 2.5 Gb/s 12 256 MB DDR2 Three SAS x4 (SFF-8087) 0, 1, 1E, 10, 5, 5EE, 50,6, 60, JBOD Yes SATA, SATA II, SAS 12 (or up to 100 with expanders) Yes I2C and SGPIO Yes Yes Yes Adaptec Battery Module 800 (sold separately-see page 17...
... Your RAID Controller ● 21 About the Adaptec 31205 The Adaptec 31205 is a SAS RAID controller with these features: I2C connector for CN2 Activity LED Phys and connectors FE Aggregate LED connectors CB A I2C connector for CN1 I2C connector for CN0 CN0 Alarm connector Mode 0 Flash connector Battery connector CN1 3 internal SAS connectors ... Half-size PCIe x8 2.5 Gb/s 12 256 MB DDR2 Three SAS x4 (SFF-8087) 0, 1, 1E, 10, 5, 5EE, 50,6, 60, JBOD Yes SATA, SATA II, SAS 12 (or up to 100 with expanders) Yes I2C and SGPIO Yes Yes Yes Adaptec Battery Module 800 (sold separately-see page 17...
User Guide
Page 22
...RAID Controller ● 22 About the Adaptec 31605 The Adaptec 31605 is a SAS RAID controller with these features: Activity LED Phys and connectors FE Aggregate LED connectors D CBA I2C connector for CN3 I2C connector for CN2 I2C connector for CN1 I2C connector for CN0 CN0 Alarm connector Mode 0 Flash connector Battery connector CN1 4 internal SAS... Half-size PCIe x8 2.5 Gb/s 16 256 MB DDR2 Four SAS x4 (SFF-8087) 0, 1, 1E, 10, 5, 5EE, 50,6, 60, JBOD Yes SATA, SATA II, SAS 16 (or up to 100 with expanders) Yes I2C and SGPIO Yes Yes Yes Adaptec Battery Module 800 (sold separately-see page 17...
...RAID Controller ● 22 About the Adaptec 31605 The Adaptec 31605 is a SAS RAID controller with these features: Activity LED Phys and connectors FE Aggregate LED connectors D CBA I2C connector for CN3 I2C connector for CN2 I2C connector for CN1 I2C connector for CN0 CN0 Alarm connector Mode 0 Flash connector Battery connector CN1 4 internal SAS... Half-size PCIe x8 2.5 Gb/s 16 256 MB DDR2 Four SAS x4 (SFF-8087) 0, 1, 1E, 10, 5, 5EE, 50,6, 60, JBOD Yes SATA, SATA II, SAS 16 (or up to 100 with expanders) Yes I2C and SGPIO Yes Yes Yes Adaptec Battery Module 800 (sold separately-see page 17...
User Guide
Page 24
Audible alarm Yes Battery backup module Adaptec Battery Module 600 (sold separately-see page 17) 1 256 MB also available Chapter 3: About Your RAID Controller ● 24 About the Adaptec 4800SAS The Adaptec 4800SAS is appropriate for battery backup module) Alarm connector Mode 0 Flash connector Activity LED connector (top 2 left/right pins) 1 external SAS connector Battery connector PCI-X connector...
Audible alarm Yes Battery backup module Adaptec Battery Module 600 (sold separately-see page 17) 1 256 MB also available Chapter 3: About Your RAID Controller ● 24 About the Adaptec 4800SAS The Adaptec 4800SAS is appropriate for battery backup module) Alarm connector Mode 0 Flash connector Activity LED connector (top 2 left/right pins) 1 external SAS connector Battery connector PCI-X connector...
User Guide
Page 25
...RAID Controller ● 25 About the Adaptec 4805SAS The Adaptec 4805SAS is appropriate for battery backup module) Alarm connector Mode 0 Flash connector Activity LED connector (top 2 left/right pins) 1 external SAS connector Battery connector PCIe connector Diag LED Activity LED Power LED Activity LED Phy 7 6 5 4 32 10 Back side of Controller... a SAS RAID controller with these features: Two 4-wide internal SAS connectors Mounting bracket Charge LED (for most environments. Audible Alarm Yes Battery backup module Adaptec Battery Module 600 (sold separately-see page 17) 1 256 MB ...
...RAID Controller ● 25 About the Adaptec 4805SAS The Adaptec 4805SAS is appropriate for battery backup module) Alarm connector Mode 0 Flash connector Activity LED connector (top 2 left/right pins) 1 external SAS connector Battery connector PCIe connector Diag LED Activity LED Power LED Activity LED Phy 7 6 5 4 32 10 Back side of Controller... a SAS RAID controller with these features: Two 4-wide internal SAS connectors Mounting bracket Charge LED (for most environments. Audible Alarm Yes Battery backup module Adaptec Battery Module 600 (sold separately-see page 17) 1 256 MB ...
User Guide
Page 26
However, this controller. Chapter 3: About Your RAID Controller ● 26 About the Adaptec 2420SA The Adaptec 2420SA is a SATA II RAID controller with these features: SATA ports 01 23 LED connector Mode 0 Flash connector Activity LED connector Battery connector I2C connector PCI-X...IRQ LED Charge LED (for battery backup module) Diag LEDs Back side of Controller Form Factor Half-size Bus compatibility PCI-X, 3.3 V PCI-X bus width 64-bit PCI-X bus speed 133 MHz Standard cache 256 MB Connectors 4x SATA connector RAID levels 0, 1, 1E, 5, 5EE, 6, 10 Simple volume Yes Disk ...
However, this controller. Chapter 3: About Your RAID Controller ● 26 About the Adaptec 2420SA The Adaptec 2420SA is a SATA II RAID controller with these features: SATA ports 01 23 LED connector Mode 0 Flash connector Activity LED connector Battery connector I2C connector PCI-X...IRQ LED Charge LED (for battery backup module) Diag LEDs Back side of Controller Form Factor Half-size Bus compatibility PCI-X, 3.3 V PCI-X bus width 64-bit PCI-X bus speed 133 MHz Standard cache 256 MB Connectors 4x SATA connector RAID levels 0, 1, 1E, 5, 5EE, 6, 10 Simple volume Yes Disk ...
User Guide
Page 27
However, this controller. Chapter 3: About Your RAID Controller ● 27 About the Adaptec 2820SA The Adaptec 2820SA is a SATA II RAID controller with these features: 01 SATA ports 234 5 6 7 Activity LED connector Mode 0 Flash connector LED connectors port 0-3 LED connectors port 0-3 I2C ... 10 Charge LED (for battery backup module) Diag LEDs Back side of Controller Form Factor Half-size Bus compatibility PCI-X, 3.3 V PCI-X bus width 64-bit PCI-X bus speed 133 MHz Standard cache 256 MB Connectors 8x SATA connector RAID levels 0, 1, 1E, 5, 5EE, 6, 10, 50, 60 Simple ...
However, this controller. Chapter 3: About Your RAID Controller ● 27 About the Adaptec 2820SA The Adaptec 2820SA is a SATA II RAID controller with these features: 01 SATA ports 234 5 6 7 Activity LED connector Mode 0 Flash connector LED connectors port 0-3 LED connectors port 0-3 I2C ... 10 Charge LED (for battery backup module) Diag LEDs Back side of Controller Form Factor Half-size Bus compatibility PCI-X, 3.3 V PCI-X bus width 64-bit PCI-X bus speed 133 MHz Standard cache 256 MB Connectors 8x SATA connector RAID levels 0, 1, 1E, 5, 5EE, 6, 10, 50, 60 Simple ...
User Guide
Page 45
Press Enter to use the default (Enable always). Property Line Array Type Array Label Array Size Stripe Size Read Caching Write Caching Create RAID via [Done] Entry or Selection Select RAID 5, then press Enter. Press Enter to use the default (Yes). You can now be used. However, performance is reduced until the Exit... disk. Press Enter. 10 When a cache warning message displays, type Y. 11 Once the array is created, a message displays telling you want to use the default (256 KB). Press Enter, then press Enter again to the ACU Menu.
Press Enter to use the default (Enable always). Property Line Array Type Array Label Array Size Stripe Size Read Caching Write Caching Create RAID via [Done] Entry or Selection Select RAID 5, then press Enter. Press Enter to use the default (Yes). You can now be used. However, performance is reduced until the Exit... disk. Press Enter. 10 When a cache warning message displays, type Y. 11 Once the array is created, a message displays telling you want to use the default (256 KB). Press Enter, then press Enter again to the ACU Menu.
User Guide
Page 97
.... No default. Prior to use when creating a redundant array. No default. No Specifies hot spares to assign to the controller. See page 99. For example: Array=MyData Drives Keyword Drives is 256. The other required array definition keywords are listed in creating the array. Array definition keywords and descriptions are Drives and...
.... No default. Prior to use when creating a redundant array. No default. No Specifies hot spares to assign to the controller. See page 99. For example: Array=MyData Drives Keyword Drives is 256. The other required array definition keywords are listed in creating the array. Array definition keywords and descriptions are Drives and...
User Guide
Page 99
... be completed before you can begin using the array. ● Quick Init-Makes the array available immediately, but allows you to use when creating a redundant (RAID 1, 1E, 10, 5, 5EE, 50, 6 and 60) array. Note: A unit keyword is written to the disk drive (called full-stripe write mode),...For example: ReadCache=Yes Size Keyword The Size keyword specifies the size of a striped array (RAID 0, 10, 5, 5, 5EE, 50, 6 or 60). For example: StripeSize=256 The possible values for StripeSize are 16, 32, 64, 128, 256, 512 and 1024 KB. Otherwise, specify the size as data is required with an error....
... be completed before you can begin using the array. ● Quick Init-Makes the array available immediately, but allows you to use when creating a redundant (RAID 1, 1E, 10, 5, 5EE, 50, 6 and 60) array. Note: A unit keyword is written to the disk drive (called full-stripe write mode),...For example: ReadCache=Yes Size Keyword The Size keyword specifies the size of a striped array (RAID 0, 10, 5, 5, 5EE, 50, 6 or 60). For example: StripeSize=256 The possible values for StripeSize are 16, 32, 64, 128, 256, 512 and 1024 KB. Otherwise, specify the size as data is required with an error....