Question posted by Bbattjr on July 31st, 2019

Drain Hose

How to attach a drain hose

Current Answers

Answer #1: Posted by Murugananthens on July 31st, 2019 9:32 AM
This answer was accepted by the poster of the original question.
Murugananthens

Member since:
July 31st, 2019

Points: 1,100
1,100
points
Step1:

Move the washer into its place after you install the water supply hoses. Most washers have the drain hose preinstalled. If your washer doesn't have a preinstalled drain hose, connect the supplied hose to the machine's drain opening. Measure the height of the standpipe or sink. The lip must be at least 30 inches from the floor.

Step 2:

Hook the drain hose over the lip of the standpipe or lip of the laundry sink. If connecting to a standpipe, don't seal the hose to the pipe. Plumbing codes require that an air gap be left between the drain hose and standpipe to prevent siphoning water out of the washer. Don't lay the hose on the floor. That will drain the water out of your washer as fast as you fill it. Plug in the machine and run it through a complete cycle to check that it drains correctly.

Step 3:

Construct a standpipe out of 1 ½-inch PVC pipe if you have only a floor drain and no sink or standpipe in your laundry room. Cut a piece of PVC pipe 35 inches long. This will be the upright portion. Cement a 90-degree elbow to the bottom end of the upright pipe. Determine where on the wall to install the upright. Cut a second piece of pipe to reach from the upright to the floor drain. Cement a second 90-degree elbow to one end of this horizontal pipe so it points into the floor drain. Cement the other end to the elbow of the upright. Fasten the upright to the wall with pipe straps. Hook the washer drain line over the lip of the upright.

Related Zenith ZD300 Manual Pages

Owners Manual - Page 9

... the outlet before use the plug with a three-prong grounding plug. Owner's Manual 9 Preferred method Ensure proper ground exists before you use the dehumidifier. WARNING: Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated, and...
Owners Manual - Page 12

...1. Water level control switch Disposing of garden hose to the threaded drain hose connection to carry water to hose connector drain hose connection, do not bend or kink the hose. Empty the bucket manually. Connect a garden hose to drop on Rear Grille. (Fig3-1,3-2) HOSE CONNECTOR Fig3-2 Fig3-1 4. Fig4-1 Fig4-2 NOTICE The hose attachment will turn off The dehumidifier will accept...
Owners Manual - Page 14

... designed to serve you should check your dehumidifier annually. Cleaning the front case, bucket and cabinet Clean the front case and the cabinet with a vacuum attachment or brush. Remove water bucket from receptacle before performing any maintenance. • Be careful when cleaning the coils. You may want an Authorized Service Center...
Owners Manual - Page 15

...to remove the moisture. s Room Humidity is high • Make sure the dehumidifier plug is attached. • See Removing and Emptying The Water Bucket. • Change the humidity setting. &#... to lower the humidity. • Check that all doors and windows to low Humidity. s Drain hose connection may not be loose. s Doors and windows may be closed . • Install the...

Similar Questions

Dehumidifier Does Not Collect Water And Stops Running After A Couple Of Minutes
Hello, My dehumidifier ZD300 does not collect water. It starts working, everything looks normal and ...
(Posted by igorgoldfarb 2 months ago)
Where Do A Find A New Bucket?
(Posted by drehrer 10 years ago)
Zenith Dehumidifier Problem
I have a zd300 dehumidifier, which runs just fine, but collects nothing--coukld it be the humidity s...
(Posted by rharrivel 11 years ago)
Zenith Zd300 Dehumidifier Is Forming Moisture On Top Surface,also Has Spot Icing
what is causing the moisture formation?
(Posted by mbqualls 11 years ago)
The Bucket Full Light Is Blinking On A Zd300 Dehumidifier
The bucket full light is blinking on a zd300 dehumidifier. How do you reset this?
(Posted by kevledwith 11 years ago)
Ask a New Question
Use the box below to post a new question about this Zenith product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Zenith Manuals

Find free Zenith ZD300 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Zenith Reviews

View thousands of Zenith user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Zenith customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Zenith customer service rankings, employee comments and much more from our sister site.

Zenith Recalls

Find comprehensive Zenith recall information updated hourly on RecallOwl.com.