Sony KP-43HT20 Support Question
Find answers below for this question about Sony KP-43HT20 - 43" Hi-scan 1080i™ Tabletop Pjtv.Need a Sony KP-43HT20 manual? We have 5 online manuals for this item!
Question posted by rrobinson5590 on May 7th, 2015
Kp-43ht20 Standby Light Blinks Red 6 Times, Pause, Then Blinks 6 Times Again. No
Current Answers
Answer #1: Posted by OldOwl on June 25th, 2015 7:36 AM
here are the list of codes and what they generally mean on my set (which applies to many recent model Sony Television sets. Sony has provided a "self-diagnosis function" with your TV, that in the case of abnormalities or problems the LED or red blinking light on the Timer/Standby indicator flashes a number of times to indicate the issue. Here are the values of the various blinks.
- 0 times, Diagnosis: Power does not turn on. Possible causes include: Power cord is not plugged in, Fuse is burned out (F6001) (G board). Symptoms of the problem: Power does not come on, No power is supplied to the unit, AC power supply is faulty.
- 2 times, Diagnosis: B overcurrent (OCP). Possible causes: H. OUT (Q8024) is shorted. (D board), +B PWM (Q8035, 8038) is shorted. (D board) Symptoms of the problem: Power does not come on, Load on power line is shorted.
- 3 times, Diagnosis: +B overvoltage (OVP). Possible causes: IC501 is faulty (G board), IC5002 is faulty (G board). Symptoms of the problem: TV has entered standby mode.
- 4 times, Diagnosis: Vertical deflection stopped. Possible causes: +- 15V is not supplied. (D board), IC8003 is faulty. (A board) Symptoms of the problem: TV has entered standby state after horizontal raster, Vertical deflection pulse is stopped, Power line is shorted or power supply is stopped.
- 5 times, Diagnosis: White balance failure (Not balanced) Possible causes: Video out (IC7101, 7201, 7301) is faulty (CR, CG, CB board), CRT drive (IC309) is faulty (A board), G2 is improperly adjusted. Symptoms of the problem: No raster is generated, CRT cathode current detection reference pulse output is small.
- 6 times, Diagnosis: LOW B OCP/OVP (Overcurrent/over voltage). Possible causes: +5 line is overloaded. (A, B boards), +5 line is shorted. (A, B boards). Symptoms of the problem: No picture.
- 7 times, Diagnosis: Horizontal deflection stopped. Possible cause: Q8035, 8038 is shorted. (D board)
- 8 times, Diagnosis: High voltage error. Possible cause: T8005 is faulty. (D board)
- 9 times, Diagnosis: Audio error. Possible causes: +- 19V line is shorted. (A, B boards), IC708 is faulty. (A board), PS701 or PS702 is opened. (A board). Symptoms of the problem: No sound