Sharp XE-A202 Support Question
Find answers below for this question about Sharp XE-A202 - Electronic Cash Register.Need a Sharp XE-A202 manual? We have 3 online manuals for this item!
Question posted by elainehawes on May 25th, 2012
Till Wont Open
I can open the till manually, i have a sharp xea 202 but it wont open once ive completed a transaction
Current Answers
Answer #1: Posted by cashregisterguy on July 29th, 2012 8:33 PM
Take the plastic insert and the drawer tray out. Have a look into the back of the drawer at the two white wires. If one has a small cut in it, the machine has the factory fault and has blown the drawer drive circuit. It will also need to have that wire insulated and then dressed out of the way of the drawer tray. Common fault. Many failed under warranty.
**********
If anyone needs more information, the Sharp XE-A202 manuals are here:
http://the-checkout-tech.com/manuals/cashregisters/Sharp12.php
Related Sharp XE-A202 Manual Pages
Similar Questions
Sharp Electronic Cash Register Drawer Wont Open
(Posted by makam 9 years ago)
Sharp Electronic Cash Register Xe-a203 Wont Open
(Posted by djbooeta 10 years ago)
Sharp Electronic Cash Register Xe-a202 Wont Open Says Error
(Posted by pcmarsonoft 10 years ago)
Sharp Electronic Cash Register Xe-a106 Drawer Wont Open
(Posted by vizThenm 10 years ago)
Sharp Electronic Cash Register Wont Open
(Posted by dptxal 10 years ago)