Sharp CV-P10RC Support Question
Find answers below for this question about Sharp CV-P10RC.Need a Sharp CV-P10RC manual? We have 1 online manual for this item!
Question posted by dhardou on August 19th, 2014
Where Is The Drain Pan Located On The Sharp Ion Generator Air Conditioner
cv-2p10sc
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related Sharp CV-P10RC Manual Pages
CV-P10RC Operation Manual - Page 3
... (U.S E-2 • CONSUMER LIMITED WARRANTY (U.S E-3 • PRECAUTIONS E-4 • LOCATION E-7 • INCLUDED E-7 • PART NAMES E-8 • INSTALL WINDOW PANEL ...SHARP ROOM AIR CONDITIONER CV-P10RC
This device complies with Part 18 of your new air conditioner. Responsible Party: SHARP ELECTRONICS CORPORATION. Sharp Plaza, Mahwah, New Jersey 07495-1163 TEL: 1-800-BE-SHARP...
CV-P10RC Operation Manual - Page 4
... OF PURCHASE Dealer Name Address City State Zip Telephone
TO PHONE: Dial 1-800-BE-SHARP (237-4277) for:
SERVICE (for your nearest Sharp Authorized Servicer) PARTS (for reporting loss or theft, please record below the model and serial number located on the back side of the problem. FOR CUSTOMER ASSISTANCE (the United States...
CV-P10RC Operation Manual - Page 5
...otherwise.
From a Sharp Authorized Servicer located in addition to whatever implied warranties may be granted to your Product. Contact your Sharp Authorized Servicer to ... consumer purchaser that this additional period.
USERS
SHARP ELECTRONICS CORPORATION warrants to Obtain Service:
CV-P10RC
Portable Air Conditioner. ALL IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF ...
CV-P10RC Operation Manual - Page 6
... plug functions normally.
• This power plug must be replaced with any abnormality with a built-in fuse. WARNING FOR POWER SUPPLY CORD
• This air conditioner uses a plug with the air conditioner (ex. Pulling or misuse of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the room...
CV-P10RC Operation Manual - Page 7
...obstacles. If a grounding adapter is used . Water can result in the risk of electric shock. Drained water may freeze inside the hose, causing water inside the unit to overflow into the ... plug can cause electrical shock or equipment damage.
• Drainage should be performed whenever moving the air conditioner. (See Page 27) If any water remains in the tank, it may spill out while being...
CV-P10RC Operation Manual - Page 8
...air outlet, but this case, perform drainage to drain out water within three minutes, a protective device in the unit may cause the unit to wait at a slower speed. If you restart the air conditioner...problem with the unit.
• This air conditioner blows the warm air generated by your unit freezing up? There is reinstated, restart the air conditioner. Setting the unit to a higher ...
CV-P10RC Operation Manual - Page 9
...it should be cut down in size because the
window is too narrow for efficient air-conditioning. Use caution when rolling on a smooth, level floor strong enough to support the... the unit on carpet surfaces. Tape measure or ruler 3. ENGLISH
LOCATION
• The air conditioner should only be placed within reach of a properly rated grounded socket.
• Never place ...
CV-P10RC Operation Manual - Page 10
... control signal receiver window
7 6 POWER Button
8
9
7 OPERATION Lamp (red)
0
8 TIMER Lamp (orange)
0
9 MEGA COOL Lamp (green)
0
0 Air inlet
REAR VIEW
q
q Exhaust air outlet
w
w Window exhaust adapter
e
e Exhaust hose
r
r Remote control hook
t t Air filters
y
u
y Drainage nozzle and stopcock
u Power supply cord hooks
i Drainpipe nozzle and stopcock
i
o Power supply...
CV-P10RC Operation Manual - Page 18
...Battery cover
NOTES:
• The battery should last approximately one year under normal use the air conditioner if the above procedure cannot be using the unit for a prolonged period, remove the batteries... power plug before use . The circuit breaker is activated, power is supplied, and the air conditioner is functioning correctly.
4 Press the RESET button until you will hear a CLICK if the...
CV-P10RC Operation Manual - Page 21
...be discharged from the drainage nozzle.
• Always perform this mode, the air conditioner dehumidifies the room. This will help to slightly drop the room ... drainpipe nozzle and that the drainage nozzle is covered with container, the unit generates heat during operation.
4 Attach the drain grommet to a standard commercially-available hose. (5/8" inner diameter, 7/8" outer diameter...
CV-P10RC Operation Manual - Page 22
VENTILATION MODE
In this mode, the air conditioner simply circulates the air without cooling it. Ensure that the nozzle has not been damaged.
1 Press the ...desired fan speed. Install the exhaust hose (See Page 14), turn off . FAN MODE
In this mode, the air conditioner ventilates the air to outdoors.
COOL DEHUM FAN VENT
2
2 Press the POWER button to start operation. • The red ...
CV-P10RC Operation Manual - Page 23
... vertical louver as shown in the COOL or DEHUMIDIFI-
ENGLISH
TO CHANGE AIR FLOW DIRECTION
UP / DOWN AIR FLOW DIRECTION
1 Press the LOUVERS button on the louvers.
Do not ... to "QUIET ( )" for an extended period of time. NOTE
• During VENTILATION mode, UP/DOWN air flow direction cannot be set to malfunction when the remote
control is used for an extended period of ...
CV-P10RC Operation Manual - Page 24
..., press the LIGHTS button.
• PLASMACLUSTER operation cannot be activated the next time you turn on the unit will light. PLASMACLUSTER OPERATION
The Plasmacluster ion generator inside the air conditioner will be set during operation.
• The remote control will display "
".
• The blue PLASMACLUSTER lamp on the unit will turn off . NOTES:
•...
CV-P10RC Operation Manual - Page 25
... off. TO CANCEL
Press the CANCEL button.
1
• The orange TIMER lamp on the unit will light.
ENGLISH
MEGA COOL OPERATION
In this operation, the air conditioner fan works at the formerly set condition.
• If you wish to operate the unit for another hour before the ONE-HOUR OFF TIMER is...
CV-P10RC Operation Manual - Page 29
...and the TIMER, OPERATION and MEGA COOL lamps are blinking. (This indicates that may be drained
Stopcock
out is removed, a small amount of water that may be blinking.
7 When...time.
1 Carry out the above procedures from 1 to collect the water before draining.
Drainage nozzle Stopcock
"OPEN" position
Drain grommet Hose
Hose band
8 Remove the hose from the drainage nozzle, and replace ...
CV-P10RC Operation Manual - Page 30
... reduced or stop completely if the insect guard net becomes clogged with dust, the airflow will be reduced, resulting in the FAN or VENTILATION mode for a ... FILTERS • Use a vacuum cleaner to drain out water within the unit. (See Page 27 "When the unit is clogged with dust. Insect guard net
MAINTENANCE AFTER AIR CONDITIONER SEASON
1 Perform drainage to remove any maintenance....
CV-P10RC Operation Manual - Page 31
...unit.
• A low buzzing noise is emitted when the unit is generating Plasmacluster ions. • This air conditioner evaporates water condensed during operation. Although water flowing sound way be... perfectly normal.
• A soft, swishing noise can be drained. (See page27) • Check the power plug. (See page16)
AIR CONDITIONER DOES NOT COOL PROPERLY
• Is it set properly? ...
Similar Questions
Sharp Portable Air Conditioner Cv-p10rc Mega Cool Does Not Turn On.
(Posted by angelsChris2 9 years ago)
How To Attach The Drain Hose On A Portable Air Conditioner
(Posted by Choaspopopo 10 years ago)
How To Drain Water From Sharp Portable Air Conditioner
(Posted by 3undekhar 10 years ago)
I Have A New Sharp 'library Quiet' Portable Air Conditioner.Does Anyone Know O
I bought a hose to drain the unit and placed the hose in a jelly roll pan. That works fine....but I...
I bought a hose to drain the unit and placed the hose in a jelly roll pan. That works fine....but I...
(Posted by gretsl 11 years ago)