Honeywell RTH2310B Support Question
Find answers below for this question about Honeywell RTH2310B.Need a Honeywell RTH2310B manual? We have 1 online manual for this item!
Question posted by Luciatrumble on January 23rd, 2014
Battery
Current Answers
Answer #1: Posted by BusterDoogen on January 23rd, 2014 7:56 PM
Screen is blank. • Ensure two fresh AA alkaline batteries are
correctly installed.
Temperature settings cannot be
changed.
• You are setting the temperature outside its
allowable range:
• Heat: 41 °F to 82 °F (5 °C to 28 °C )
• Cool: 59 °F to 95 °F (15 °C to 35 °C)
is flashing. • The compressor protection delay is underway.
Wait for the delay to end (maximum of 5 minutes).
HI appears on the screen. • The ambient (measured) temperature is above
122 °F (50 °C).
LO appears on the screen. • The ambient (measured) temperature is below
23 °F (-5 °C). Date & time have to be manually reset.
I hope this is helpful to you!
Please respond to my effort to provide you with the best possible solution by using the "Acceptable Solution" and/or the "Helpful" buttons when the answer has proven to be helpful. Please feel free to submit further info for your question, if a solution was not provided. I appreciate the opportunity to serve you!