Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Honeywell CT3200 Manual Pages

Owner's Manual - Page 1

Your new thermostat will automatically control the temperature in your new Honeywell MagicStat® Programmable Thermostat. MagicStat® CT3200 Programmable Thermostat Installation and Programming Instructions Weekday/Weekend (5-day/2-day) Programmable Heat and/or Cool Low Voltage (20 to 30 Vac) Thermostat and Mounting Plate Model CT3200 Welcome to the world of Contents Installation 2...
Owner's Manual - Page 2

... local waste management authority for instructions regarding recycling and the proper disposal of thermostat is not compatible with no auxiliary or backup heat. Fig. 1 MERCURY SWITCH Recycling Thermostat If you have the right thermostat Make sure that the CT3200 is the right thermostat for your system, visit us on the Web at www.honeywell.com...
Owner's Manual - Page 3

... and cooling systems are working properly. Required tools and supplies Optional tools • Two AA alkaline batteries. Gather the needed tools and supplies listed below 50°F (10°C). 69-0653-6 INSTALLATION 3 Make sure that your new thermostat. IMPORTANT: To avoid damaging the compressor in the air conditioner, do not operate the cooling...
Owner's Manual - Page 4

... Fig. 4 M19086 WIRES THROUGH WALL OPENING 4 INSTALLATION M20133 a. b. d. Disconnect the wires from the old thermostat and wrap the wires around a pencil to the heating/cooling system, either at the furnace or at the fuse/circuit breaker panel. Turn off power to keep them from the wall, but do not match the letters...
Owner's Manual - Page 5

Step 3. Separate the mounting plate from the thermostat using a coin, as shown in drywall, gently tap the anchors that were provided into each of the wires are flush with the wall. c. Make sure ...
Owner's Manual - Page 6

... screw C out one turn. d. To install the batteries, see the instructions that your new thermostat for a warm air, gas, or oil heating system. To program the thermostat, see the instructions on the wall. See the Heating System Table on the back of the thermostat to maintain accurate temperature control, minimize swings in degrees Fahrenheit (°F). Set...
Owner's Manual - Page 7

... A-out one turn B-leave in A-leave in B-out one complete turn Fuel switch F F F E Step 5. Using the labels on the wires, match the letter of your new thermostat. c. See the special wiring instructions on the furnace.) High-efficiency furnace such as shown in . (8 mm) STRIP INSERT STRAIGHT UNDER SCREW HEAD M20125 a. Loosen the...
Owner's Manual - Page 8

... in the OFF position. Mount the thermostat Fig. 11 Fig. 12 a. c. Go to program the thermostat. Align the tabs at the top of the thermostat with the tabs at the top of the thermostat (Fig. 12). b. Install the batteries Fig. 13 Fig. 14 M1719C REMOVING BATTERY DOOR 8 INSTALLATION M20131 IMPORTANT: Batteries must be installed for programming and...
Owner's Manual - Page 9

... system is most likely a variation of purchase. Place the wires where they will not interfere with the operation of the new thermostat. See the compatibility table on page 4 at step 2e. Three thermostat wires If you disconnect the wires, do not label them where they will not interfere with the operation of the...
Owner's Manual - Page 10

... cooling Heat Cooling Fan Changeover in cool (O terminal) or changeover in 5-wire systems. 10 INSTALLATION 69-0653-6 Transformer common. Five wires connected to the old thermostat Your new thermostat has a factory-installed metal jumper between R and Rc terminals in heat (B terminal). Fig. 15 JUMPER (FACTORY- Remove the jumper before wiring the R and Rc...
Owner's Manual - Page 11

...1 Fan switch-Selects automatic fan operation or fan on (page 17) 9 2 Set Schedule-Puts the thermostat into programming 10 mode (page 14) 11 3 Set Clock/Day-Sets the clock and day (page ...11 Temp Warmer and Cooler-Sets the temperature warmer and cooler (page 14) 12 Run Program-Returns thermostat to normal operating mode 13 Hold Temp-Holds a selected temperature (page 19) 14 System switch-Selects...
Owner's Manual - Page 12

.... 12 PROGRAMMING 69-0653-6 Press and hold or until the current day is displayed. Fig. 17 b. Press once. Learn about the programming features Your 3200 thermostat allows you to program schedules for both a heating season and a cooling season. • During the heating season, you can set up to four program periods...
Owner's Manual - Page 13

... comfortable temperature for this period. The time when you get ready to program your thermostat, it will remain in effect until you decide not to program weekend schedules, the... temperature that is programmed for the weekday SLEEP schedule will automatically control heating at 68°F (20°C), and cooling at a comfortable temperature for this ...
Owner's Manual - Page 16

Check out the system Verify that your heating system works a. c. Note: When the cooling setting is changed, the thermostat may delay up to COOL. Set the System switch to 5 minutes before turning on the air conditioner. Repeat steps 3c. Verify that your cooling system ...
Owner's Manual - Page 17

.... The time is displayed. Press once. Switch Fan Setting Result Auto On A single-speed fan turns on the bottom of the thermostat faceplate (Fig. 16 page 11) control the operation of the thermostat. 69-0653-6 OPERATION 17 g. Press once. c. Set the Fan and System switches The switches on automatically with the furnace. The...
Owner's Manual - Page 18

... to reprogram. b. However, if the display is set in the thermostat. Heat The thermostat controls your air conditioning system. Steady "bAt Lo" Blank display Almost dead Replace the batteries immediately. Open the battery door. Your heating/cooling system is not operating. d. Install the new batteries. Then see : Batteries are leaving home for five to ten seconds, and return...
Owner's Manual - Page 21

... current room temperature and the SYSTEM ON arrow is displayed, the thermostat is set the System switch to reset the thermostat. Display will not come on Temperature display will not come on Then... • Make sure the batteries are correct. Then replace the batteries correctly. Reprogram if necessary. • Check that the AM and PM...
Owner's Manual - Page 22

...reset if necessary. If the temperature setting is lower than the current room temperature and the SYSTEM ON arrow is displayed, the thermostat is blank or says "bAt Lo," install fresh batteries... assistance, call , please have the following information available: • Thermostat model number and serial code (located under the battery cover) • Type of heating/cooling system (hot water, warm...
Owner's Manual - Page 23

... warranty shall not apply if it is defective, (i) return it , postage prepaid, to the following address: Honeywell Inc. Limited warranty Honeywell warrants this product, excluding battery, to be to repair or replace the product within a reasonable period of time. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT...
Owner's Manual - Page 24

Home and Building Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 69-0653-6 Rev. 9-01 Home and Building Control Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Scarborough, Ontario M1V 4Z9 Printed in the U.S.A. www.honeywell.com/yourhome

Similar Questions

Bat Lo ,, Does Not Reset With New Batteries
bat lo ,, does not reset with new batteries
(Posted by zensgarden 7 years ago)
Thermostat Indicated It Needs New Batteries
after putting i new batteries thermostat showa no numbers
(Posted by karlleni 8 years ago)
Ask a New Question
Use the box below to post a new question about this Honeywell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Honeywell Manuals

Find free Honeywell CT3200 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Honeywell Reviews

View thousands of Honeywell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Honeywell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Honeywell customer service rankings, employee comments and much more from our sister site.

Honeywell Recalls

Find comprehensive Honeywell recall information updated hourly on RecallOwl.com.