Honeywell CT3200 Support Question
Find answers below for this question about Honeywell CT3200.Need a Honeywell CT3200 manual? We have 1 online manual for this item!
Question posted by sdceasyg on August 7th, 2014
Honeywell Thermostat Ct3200- Cooling Does Not Come On
Current Answers
Answer #1: Posted by BusterDoogen on August 24th, 2014 1:44 PM
Cooling does not come on • Check that the System switch is set to Cool.
• Check the system fuse or circuit breaker and replace or reset if necessary.
• Check for correct wiring and good connections.
• If display is blank or says “bAt Lo,” install fresh batteries.
• The thermostat has a built-in time delay on cooling. Allow 5-10 minutes after changing setting before air conditioner starts.
• If temperature setting is lower than room temperature and SYSTEM ON arrow is displayed, thermostat is operating correctly. Contact ac contractor.
I hope this is helpful to you!
Please respond to my effort to provide you with the best possible solution by using the "Acceptable Solution" and/or the "Helpful" buttons when the answer has proven to be helpful. Please feel free to submit further info for your question, if a solution was not provided. I appreciate the opportunity to serve you