HP DL385 Support Question
Find answers below for this question about HP DL385 - ProLiant - G5.Need a HP DL385 manual? We have 28 online manuals for this item!
Question posted by flippGrowm on August 15th, 2014
How To Fix Sun Server Power Supply
The person who posted this question about this HP product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related HP DL385 Manual Pages
Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25 - Page 93
...:
• sysName • cpqHoTrapFlags
Supporting SNMP Trap Description: "Remote Insight battery failed." Supporting SNMP Trap Data:
• sysName • cpqHoTrapFlags
Supporting SNMP Trap Description: "The server power supply status has become degraded." SNMP Trap: cpqSm2BatteryFailed - 9004 in CPQSM2.MIB Symptom: Remote Insight/Integrated Lights-Out Unauthorized Login Attempts.
HP ProLiant Servers Troubleshooting Guide - Page 3
... diagnosis flowchart ...24 General diagnosis flowchart ...25 Power-on problems flowchart ...26 POST problems flowchart ...29 Operating system boot problems flowchart 31 Server fault indications flowchart ...32
Hardware problems ...36
Procedures for all ProLiant servers...36 Power problems ...36
Power source problems ...36 Power supply problems ...36 UPS problems ...37 General hardware problems...
HP ProLiant Servers Troubleshooting Guide - Page 7
...Power Supplies Not Redundant 158 System Power Supply Failure (Power Supply X 158 Unrecoverable Host Bus Data Parity Error 158 Uncorrectable Memory Error (Slot X, Memory Module Y 159 HP BladeSystem p-Class infrastructure error codes 159 Server blade management module error codes 159 Power...authorized reseller 171 Customer self repair...171 Server information you need ...172 Operating system ...
HP ProLiant Servers Troubleshooting Guide - Page 36
... Replace the power cord with a power supply, replace the power supply.
For more information, see the server documentation on ...Power On/Standby button to be sure it is in this section are comprehensive and include steps about or references to its original position after being pressed, be sure you press the switch firmly. 2. Hardware problems
Procedures for all ProLiant servers...
HP ProLiant Servers Troubleshooting Guide - Page 120
... the card. Action: Refer to complete redundancy.
Action: Do one of the following:
• Install a power supply. • Replace failed power supplies to the server documentation for supported processors.
This is not an error. Parity Check 2 - Action: Reboot the server.
This system contains a valid backup system ROM. For embedded PCI devices, run ROMPAQ to identify failed...
HP ProLiant Servers Troubleshooting Guide - Page 149
Action: 1.
Reboot the server after replacing each item: a. Drive backplane c. Ports 1I, 1E: Storage ...information, refer to Prevent Overheating SCSI Port Y: Redundant Power Supply Malfunction Detected SCSI Port Y: Wide SCSI Transfer Failed SCSI Port Y: Interrupt Signal Inoperative SCSI Port y: Unsupported ProLiant Storage System Detected
Audible Beeps: None Possible Cause: ...
HP ProLiant Servers Troubleshooting Guide - Page 150
... ROMPaq is amber instead of green, this indicates a
redundant power supply failure.
• If the message indicates to the latest ...server.
• When powering down the system, the server must be powered down before powering down any
external storage systems.
1783-Slot X Drive Array Controller Failure
Audible Beeps: None Possible Cause: Controller failed. If the ProLiant Storage System power...
HP ProLiant Servers Troubleshooting Guide - Page 162
... more information, refer to the HP BladeSystem Maintenance and Service Guide on the HP website (http://www.hp.com/products/servers/proliant-bl/p-class/info). 3.
Power management module error codes
Power supply error codes
Location
Power Supply - For more information, refer to the HP BladeSystem Maintenance and Service Guide on the HP website (http://www.hp.com...
HP ProLiant Servers Troubleshooting Guide - Page 163
...
1.
Slot 6
LED codes
2-1 or 2-2 3-1 or 3-2 4-1 or 4-2 5-1 or 5-2 6-1 or 6-2
Action: Perform the following steps to resolve the problem. Reseat the power supply.
For more information, refer to the HP BladeSystem Maintenance and Service Guide on the HP website (http://www.hp.com/products/servers/proliant-bl/p-class/info). 2.
Location
Power Supply - Slot 3 Power Supply -
HP Insight Diagnostics User Guide - Page 5
...not supported by HP might not be detected by Power
Supply Diagnosis software using specific HP part numbers and HP servers HP Insight Diagnostics Offline Edition captures system configuration ...• HP SmartStart CD on HP ProLiant servers • HP Documentation CD or HP Documentation and Diagnostics CD on the same server or a baseline server. therefore, software information from one of...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers - Page 40
...11/06, 8/07, 5/08, 10/08,
5/09
• Servers affected-HP ProLiant DL385, DL585, BL25p, BL35p, BL45p • Description-Beginning with certain memory... A power cycle or reset is enabling the AMD™ memory scrubber. With the Solaris 10 6/06 release, Sun has introduced...unresponsive intermittently, but frequently at boot, just after a fixed amount of uptime (usually between 1 and 6 hours), ...
HP SATA DVD RW Optical Drive Installation Instructions for HP ProLiant DL servers - Page 1
... cable to the server and to electrical components, properly ground the server before beginning any installation procedure. If required, use the supplied power conversion cable.
Power down the server. 3.
The information...the operation
system instructions. 2. Nothing herein should be liable for HP ProLiant DL servers. Bluetooth is a trademark owned by its proprietor and used by Hewlett-...
HP SATA DVD-ROM Optical Drive Installation Instructions for HP ProLiant DL servers - Page 1
... drive
CAUTION: To prevent damage to the removable-media drive
bays.
6. Improper grounding can read capability for HP ProLiant DL servers. Power down the operating system as outlined in the operation system
instructions.
2. Remove the power cord from the
server and all peripheral devices. 4. Remove components that prevent access to electrical components,
properly ground the...
HP Insight Control Environment User Guide - Page 27
..., any user-defined collections relating to enable direct launch.
Server blades tend to be easily inserted into a rack-mountable enclosure to share power supplies, fans, switches, and other components with Update 1
• Support for HP ProLiant BL280c G6, BL460c G6, BL490c G6, and BL685c G6 Server Blades. • Support for HP Virtual Connect 8Gb Fibre...
HP Insight Control Environment User Guide - Page 35
... all users. Displays the name of the discovered systems in the picture view for racks and enclosures: • Servers, desktops and workstation blades • Interconnect modules • Power supply enclosure
Note: Provided for p-Class only.
• Onboard Administrator, fans, and power units Note: Provided for enclosures contains a diagram of the enclosure. You can also click...
HP Insight Control Environment User Guide - Page 44
... until it fails. Many features necessary to server components.
• Power-The VRMs/Power Supplies tab displays the state of the processor supported. If one or more sensors exceed this threshold, iLO 2 implements the recovery policy to prevent damage to operate and manage the components of HP ProLiant servers migrated from being supported.
• Processors-The...
HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet - Page 294
... is used to model power supply locations on servers.
where n represents the power supply position printed on the system." User displayable name of this Power Supply For example on Proliant, number represents the power supply position printed on ElementLocationTagDescription for this power supply location instance
Physical position of this power supply from the name displayed...
HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet - Page 303
...of the indication
Time of indication
CIM_AlertIndication
Time of the event or time of the computer system generating the indication
10-4-2 HP_DeviceIdentification: Power Supply Removed
The following format: .. for ProLiant server platforms where available. Array of firmware versions of the computer system generating the indication
Serial number of the computer system generating the indication...
HP ProLiant DL385 Generation 2 Server User Guide - Page 4
... option...50 Redundant hot-plug AC power supply option 50 DC power supply option ...51 Expansion board options...54...power cabling ...61
Configuration and utilities ...62
Configuration tools ...62 SmartStart software...62 HP ROM-Based Setup Utility...63 Array Configuration Utility ...64 Option ROM Configuration for Arrays 65 HP ProLiant Essentials Rapid Deployment Pack 65 Re-entering the server...
HP ProLiant DL385 Generation 2 Server User Guide - Page 82
... CD or on the HP website (http://www.hp.com/support)
"Power source problems" in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or on the HP website (http://www.hp.com/support)
• "Power supply problems" in the HP ProLiant Servers Troubleshooting
Guide located on the Documentation CD or on the HP website...
Similar Questions
Illegal Opcode
What can cause an illegal opcode error on a DL385p Gen8?
What can cause an illegal opcode error on a DL385p Gen8?
(Posted by ppipathos 9 years ago)
How To Upgrade Proliant Dl385 G7 Bios From Ilo
(Posted by Danibou 10 years ago)
Power Supply?
our power was shut of for a hour or two when it came back on our hp s3300f would not turn on. There...
our power was shut of for a hour or two when it came back on our hp s3300f would not turn on. There...
(Posted by scottinnh88 11 years ago)