Question posted by cptalay on June 5th, 2015

How Do I Replace A Combustion Blower On H100id1?

Service call on non-operating unit. Told my Induced Draft motor need replacement. Charge for service is $875 (not happening). Is this part available and can I replace it myself?

Current Answers

Answer #1: Posted by Autodiy on June 6th, 2015 11:09 PM
Autodiy

Member since:
May 23rd, 2014

Points: 815,136
90
points
the part is not availabe for purchase anywhere and we cannot find any replacement instructions. i think you only have one option which is the $875 option.


Www.autodiy.co.za

Related Hayward H-Series Manual Pages

Models: ABG1001 H100ID1 - Page 1

... GAS ‡ 'RQRWWU\WROLJKWDQ\DSSOLDQFH ‡ 'RQRWWRXFKDQ\HOHFWULFDOVZLWFKGRQRW use gasoline or other appliance. Installation, Operation & Service Procedures Above Ground Pool Heater Models H100ID1 & ABG1001 Unit must be installed outdoors only and below an altitude of this or any other flammable vapors or liquids in your building ‡...
Models: ABG1001 H100ID1 - Page 2

:$51,1* Failure to Maintain Proper Water Chemistry May 3UHPDWXUH+HDW([FKDQJHU'DPDJHRU)DLOXUH Cause The heat exchanger in your Hayward pool heater is state of the art in the manufacture of the heat exchanger is made from the highest quality of copper materials. The premium materials and the exacting processes used in pool heater design and manuIDFWXUH
Models: ABG1001 H100ID1 - Page 3

...UHTXLUHVYROW$&FXUUHQWDVGRHV the blower motor. Electrical system: 7KLVKHDWHULV...and birth defects or other non-potable waters. Combustible floor Figure 1 $Q$*$&HUWLILHGPDLQ...is strongly recommended that installation and service personnel performing the installation be installed... operation is recommended to the pool must be between a heater outlet and the pool/spa ...
Models: ABG1001 H100ID1 - Page 4

...of 11" W.C. The heater should shut off . After pressure testing, reconnect the gas piping to operate at low inlet gas pressures. Gas pipe size: Figure 4 Follow local gas codes for proper ...6WDUWILOWHUSXPS0DNHVXUHDOODLULVRXWRIZDWHU lines and complete system is in operation. Manifold pressure for Propane gas. ([SRVXUHWRKLJKHUSUHVVXUHVFDQ GDPDJHWKHJDVFRQWUROYDOYH...
Models: ABG1001 H100ID1 - Page 5

...unit will not operate if water flow is in proper order. This heater cannot be observed to prevent restriction of a physician. Do not tamper with an accurate thermometer; Remove any part of heart disease, circulatory problems, diabetes, or blood pressure problems should be done with the thermostat. If the pool/spa... is adjusted with the advice of combustion..., replace the...
Models: ABG1001 H100ID1 - Page 6

...VFUHZV  5HSODFHPRGXOH Combustion blower: The combustion blower provides the air that have been previously used. &$87,21 Label all wires prior to disconnection when servicing controls. Gas valve replacement: :$51,1* Do not...7XUQSXPSPDLQJDVYDOYHDQGKHDWHUSRZHURII 2. Verify proper operation after servicing. Attempts to repair gas valve. When WKHWKHUPRVWDWFDOOVIRUKHDWWKH...
Models: ABG1001 H100ID1 - Page 7

Operating Instructions Figure 6 7
Models: ABG1001 H100ID1 - Page 8

Parts List & Illustration ITEM NO. Blower Gasket (Jakel only) 4. High Limit Kit 5. IDX JKT .... Front Access Door 14. Conversion Kit, NAT to NAT 14. Burner Gasket 21. Air Pressure Switch 11. Gas Manifold 16. Combustion Blower 3. Conversion Kit, LP to LP 15. Burner 19. Burner Orifice & Air Orifice Bracket, Natural Gas 14. DESCRIPTION 1. Water ...
Models: ABG1001 H100ID1 - Page 9

...RIIUHLJKWLQVWDOODWLRQFRVWRIIXHODQG VHUYLFHODERUDWXVHU¶VH[SHQVH RUDWRXURSWLRQUHSDLUDQ\SDUWRU parts of the pool/spa heater which malfunctions under normal use and service within one year from the date of original installation for all users. /,0,7$7,2121,03/,(':$55$17,(6:($5(127/,$%/()25 $1

Similar Questions

H Series Heater Model # H250ped2 Replacement Control Board
Heater was never hooked up to gas only the water side was. Heater had a recall due to control board ...
(Posted by housosquez 8 years ago)
Spa Draining
I have placed the controler on service so I can clean the filters, once I was finished the service b...
(Posted by erniealicea 10 years ago)
Hayward H100id1 Makeing Knocking Sounds
When ignition occurs the heater "knocks" - sounds like something loose flying around or a car with a...
(Posted by bigjohn033 11 years ago)
In Ground Pool Heater 150 Elect Ign
Heater circuit breaker will pop off when I place the switch on pool
(Posted by vrago 11 years ago)
Ask a New Question
Use the box below to post a new question about this Hayward product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hayward Manuals

Find free Hayward H-Series manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hayward Reviews

View thousands of Hayward user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hayward customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Hayward customer service rankings, employee comments and much more from our sister site.

Hayward Recalls

Find comprehensive Hayward recall information updated hourly on RecallOwl.com.