Get support for GE NX-148E-RF - Security NetworX NX-8E System

GE NX-148E-RF Support Question

GE NX-148E-RF Support Question

Find answers below for this question about GE NX-148E-RF - Security NetworX NX-8E System.
Need a GE NX-148E-RF manual? We have 1 online manual for this item!
Question posted by rjkaty on February 24th, 2013

'fault' Error Message

My alarm system went off in the middle of the night, and I received a "Fault" message on one of my zones.  How can I clear this and what might be causing the error?

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related GE NX-148E-RF Manual Pages

User Manual - Page 2

...KEYS The appropriate stickers should be removed or replaced when desired. COMMERCIAL FIRE SYSTEM LCD KEYPAD Model NX-148E-CF READY light is "on" when the system is ready to arm, flashes if ready to... work with your system. FIRE light is "on" to indicate fire alarm, flashes to indicate a low battery condition. 5 FUNCTION KEYS The door (not shown) is detachable and ...
User Manual - Page 3

...your system is not partitioned. Reset Smoke Detector and Panel Reset: Press 7 NX-148E-CF 1 Door Chime: Press "Chime" key to find out how your...EMERGENCY ACTIVATION KEYS (check if enabled) Fire Auxiliary Emergency Police PROGRAMMED FUNCTIONS Abort Delay (s) Battery Test Cancel Alarm Chime Forced Arming (s) Group Bypass (s) Quick Arm (s) Re Exit Siren Test (s) These features should not ...
User Manual - Page 5

... 9 Disarming Your System 9 Cancel / Abort Feature 10 Bypassing Zones 10 Group Bypass 11 Unbypassing 11 Emergency Activation Keys 11 Function Menu 12 View Zone Status 13 Setting The Keypad Tone 13 View Alarm Memory 13 Test Function 13 Display Test Function 14 Light Control ... TONES (BEEPS 22 SERVICE DISPLAY 23 APPENDIX A - EVENT LOG 25 EMERGENCY EVACUATION PLANS 27 NX-148E-CF 3
User Manual - Page 6

...alarm event. 5. Use qualified security professionals to failure or malfunction. IF YOU DO NOT UNDERSTAND ANY PORTION OF THIS MANUAL, OR IF YOU HAVE ANY QUESTIONS ABOUT YOUR SYSTEM, CONTACT THE INSTALLING COMPANY. 4 NX-148E...YOU SHOULD BE AWARE OF THE FOLLOWING FACTS WHEN PREPARING A SAFETY/SECURITY PLAN FOR YOUR HOME/BUSINESS. 1. If your system. The LCD keypad includes 9 lights...
User Manual - Page 8

...light means a fire zone has been faulted. The power light will cause the cancel light to the central station will flash if the system has a low battery condition. Instant Message The LCD display will...armed. 6 NX-148E-CF A rapidly flashing fire light means that the time is flashing in this keypad's partition is ready to arm and "flashes" if ready to prevent an alarm. Ready Light...
User Manual - Page 10

...read "Instant", indicating that zone can be violated without an alarm. When "Auto Instant" ... indicating that a zone(s) may be unprotected and can be faulted without affecting the ...zone(s) are secure. If "Auto Instant" is inside the premise and wants protection around the perimeter. If the power light is enabled, if you have an entry System Armed Instant delay. 8 NX-148E...
User Manual - Page 11

...to leave the building. NX148E-CF 9 An alarm will be created if the "Instant" message is used if it is not entered before ...security system in the STAY mode by pressing the [STAY] key. Step 1 Step 2 Enter a valid user code. If a valid code is enabled. CHANGING MODES WHILE YOUR SYSTEM IS ARMED Step 1 Pressing the [STAY] key will turn on/off (toggle) all interior zones...
User Manual - Page 12

... the LCD prompts for any other zone(s) that need to Procedure #2. Step 3 The bypass light flashes. scroll keys will display all abortable reports will stop flashing upon exiting the Bypass Mode. The bypass light will cause the cancel light to come on until the central station has received the cancel report. CANCEL / ABORT...
User Manual - Page 14

...FUNCTION MENU The functions listed below reflects the available functions. ù=Zone Review 0=Set Tone 1=Master Mode 2=Service Check 3=Alarm Memory 44=Test 45=Display Test 46=Light Control 49=Españ...NX-148E-CF Step 2 Press the number listed on the display in the Function Menu. If your security system will sound. Each time the [r] key is pressed for two seconds, a local audible alarm ...
User Manual - Page 16

No alarms or reports will show the light number on the left. On the right side of the display pixels and LED indicators will ...to "Select Light Number 0 - 9". The LCD screen will perform a test of the X-10 device you to control up to the first language. 14 NX-148E-CF to turn the X-10 device "On" or press the - Step 2 Enter the number of the LCD display. Step 1 Press r 4 5 .
User Manual - Page 18

... reset did not execute properly. Master code? If these messages appear on the LCD screen, press the [r] key until...not, press [#] to silence the keypad. Enter your installer. 16 NX-148E-CF Reserved Output 4 ? Output 1? » DO NOT CHANGE THIS... user has access. PROMPT Outputs used to reset Smoke Detectors, Zone Troubles, and Zone Tampers. Arm only? Step 1 Disarm the system if it is...
User Manual - Page 20

.... scroll keys to the minutes, day of the [CHIME] key will be illuminated. If the chime is off and produce a momentary ding-dong sound. 18 NX-148E-CF
User Manual - Page 21

... Mode of operation allows you understand the different screen messages that will illuminate if ANY area is in the ...[#] to its assigned partition 60 seconds after an alarm report, the cancel light will revert back to ...NX-8 control panel. The keypad will illuminate and remain constant until the central station has received the cancel report. The fire light will flash if all of the zones...
User Manual - Page 22

... conditions, press [r][Area number]. For example: If Area 4 is Armed To disarm all of the partitions to the following section. 20 NX-148E-CF ARMING AND DISARMING MULTIPLE PARTITIONS To arm/disarm multiple partitions, enter a code that are Ready, and Area 5 is disarmed, [r]... are disarmed and ready to which this display will arm it. To arm all interior zones in the exit delay.
User Manual - Page 24

...exit delay. Entering code will not change when entering a code to indicate telephone line fault if selected. Pulses when one or more of the following reasons: Beeps for all ... Pulses when a FIRE zone has a trouble condition. Beeps to silence a pulsing keypad sounder. The arm/disarm state of your installer if a trouble condition exists. 22 NX-148E-CF Sounds a continuous ...
User Manual - Page 25

... this display, press r 2 . Open circuit has occurred on a control circuit. to the Central Station, but was unsuccessful. Control Ground fault Control Loss of the following message will be displayed periodically if the security system requires service. fail NX148E-CF (Optional) The Box Tamper circuit has activated. The standby battery is not operating properly...
User Manual - Page 26

... not on the bell or siren circuit. A radio receiver is being jammed. (Not applicable to all controls.) An expansion device or keypad is not reporting to the control panel. Press [r] to identify the zone. 24 NX-148E-CF Press [r] to identify the zone. A wireless or multiplexed zone device is not reporting to the control. An expansion...
User Manual - Page 27

... pushed out as new ones enter the log. Recent Close An alarm occurred within 5 minutes after the control was faulted at a specified interval. Manual Fire Keypad "Fire" has been ... activated. Open Reports user number, date, time and partition of closing. Exit Error Entry/Exit zone was armed. Start Local programming is started . Programming Start Download Download session is...
User Manual - Page 28

...system. A code has been entered. A zone "Walk-Test" mode has been activated. Reports...smoke detector requires cleaning. 26 NX-148E-CF Test has been ended. A trip has... an alarm. DISPLAY Cancel Cancel Gnd Flt Man Test Ground Fault Manual Test...RF Jammed CleanMe Expansion Event Partial Arm Listen In Service Start Service End Code Entry First Open Last Close Sprinkler Clock Set RF...
User Manual - Page 32

NX-148E-CF USERS MANUAL NX148ECFUB03 REV B (MAY2003)

Similar Questions

Where Can I Buy A Swing Down Door Replacement For A Ge Nx-148e Lcd Keypad?
I have owned the security system since 2007. It appears to not have changed by looking at the new on...
(Posted by btestrake 10 years ago)
Ge Networx Nx 148e Security System
Just bought a foreclosed home & it has two security system panels, one on each level. I do not k...
(Posted by Meadowsa 10 years ago)
Ask a New Question
Use the box below to post a new question about this GE product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

GE Manuals

Find free GE NX-148E-RF - Security NetworX NX-8E System manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

GE Reviews

View thousands of GE user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete GE customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed GE customer service rankings, employee comments and much more from our sister site.

GE Recalls

Find comprehensive GE recall information updated hourly on RecallOwl.com.