Question posted by Meadowsa on January 4th, 2014

Ge Networx Nx 148e Security System

Just bought a foreclosed home & it has two security system panels, one on each level. I do not know the master code. How do I go about resetting the codes???? Can not even turn the breaker on until I found out how to reset. please help.... there is absolutely nothing in the manual:( Thanks andrea

Current Answers

Answer #1: Posted by TommyKervz on January 4th, 2014 10:47 PM
This answer was accepted by the poster of the original question.
TommyKervz

Member since:
January 10th, 2013

Points: 17,776,843
1,100
points
Greetings. There is a Default Installer code, but this code depends on the product number of the controller box. The whole system yes can be reset and reprogrammed - Try and go through the thread here to get an idea of what it involves since your controller box's model number is not known. Just in case the manual you are having is a concise version, here is another copy. i


Hope that is helpful.
Kervz at www.satechhelp.co.za

Related GE NX-148E Manual Pages

User Manual - Page 2

PROGRAMMABLE EMERGENCY ACTIVATION KEYS NUMERIC CODE ENTRY KEYS The appropriate stickers should be applied on the keypad door for the Emergency Activation keys that are programmed... AC power is ready to arm, flashes if ready to indicate a previous alarm. COMMERCIAL FIRE SYSTEM LCD KEYPAD Model NX-148E-CF READY light is "on" when the system is present, flashes to work with your system. ...
User Manual - Page 3

To Quick Arm and Exit: Press "Exit" key. Reset Smoke Detector and Panel Reset: Press 7 NX-148E-CF 1 To Arm or Disarm or Silence Alarm: Enter your system. To Quick Arm and Stay: Press "Stay" key. Door Chime: Press "Chime" key to ... features should not be enabled on UL listed systems. NOTE: Some of the features described above may or may not be available for your user code.
User Manual - Page 5

... 14 Changing User Codes 15 Assigning User Code Authority Levels 15 Reset Function 16 Reading The Event Log 17 Adjusting The View / Brightness Of The LCD 17 Setting The System Clock 18 Using The Door Chime Feature 18 PARTITIONED SYSTEMS OPERATION 19 Lights In Partitioning Master Mode 19 Displays In The Partitioning Master Mode 19 KEYPAD CONTROL TONES...
User Manual - Page 6

... can be able to turn on it as your system. KEEP IN MIND, THE LEVEL OF SECURITY YOU WILL OBTAIN WITH THIS SYSTEM RELATES SPECIFICALLY WITH TWO MAJOR FACTORS: 1. YOU SHOULD BE AWARE OF THE FOLLOWING FACTS WHEN PREPARING A SAFETY/SECURITY PLAN FOR YOUR HOME/BUSINESS. 1. Use qualified security professionals to a telephone keypad. Care should be loud...
User Manual - Page 7

... (ARM) the security system by pressing either a four (4) or six (6) digit code that has been programmed by the installing company. Chime Feature: An option that allows the user to sound a ding-dong whenever an entry/exit door is ready to be turned on the keypad control (for Entry/Exit doors, or grants a delay to...
User Manual - Page 8

...code followed by pressing the [STAY] key when the system is "on"; It will stay on " when the chime feature is armed. 6 NX-148E.... Bypass Light The bypass light is "on" when any zone in this keypad's partition is not ready to arm because of the exit delay as a ...if the system has a low battery condition. Instant Message The LCD display will flash during the previous arm cycle. NOTE: The ...
User Manual - Page 10

...unprotected and can be violated without an alarm. The LCD display will read "Instant", indicating that zone can...affecting the ready light. If any zone(s) are secure. If Auto Bypass is not on or flashing (...NX-148E-CF ARMING YOUR SYSTEM IN THE "STAY" MODE STAY is utilized when the user is enabled, omit Step 4. System Ready Type code to arm Step 2 Enter your 4 or 6 digit user code...
User Manual - Page 12

.... Step 4 Enter the zone you know the number of the zone to exit this light is not known, refer to Procedure #2. Repeat steps 4 and 5 for any other zone(s) that need to be enabled. Entering a code followed by the [CANCEL] key while this viewing mode. 10 NX-148E-CF If a code is entered followed by the...
User Manual - Page 14

...by emergency personnel. If your security system will now begin scrolling though...Panic/Hold-Up alarms are installer level functions. The following list of ...Master Mode 2=Service Check 3=Alarm Memory 44=Test 45=Display Test 46=Light Control 49=Español 5=User PIN 6=User Authority CHIME=Walk Test 7=Detector Reset EXIT=Silent Exit 90=Log Review 91=View Settings 97=Set Date/Time 12 NX-148E...
User Manual - Page 16

...NX-148E-CF Step 2 Repeat Step 1 to revert to exit from each keypad. Step 1 Press r 4 5 . Step 2 Enter the number of the display pixels and LED indicators will flash until complete. The LCD... 2 and 3 until another key is now toggled to turn the X-10 device "On" or press the - Step 1 Press r 4 6 . The LCD keypad is pressed. DISPLAY TEST FUNCTION This function will perform a...
User Manual - Page 17

...when necessary, i.e. The LCD keypad will display the current code for a user number....codes before assigning authority levels. Step 2 Enter [master code]. Step 4 Enter the new user code for a code. Step 6 Press # while the LCD screen is prompting for a code. Step 2 Enter [master code]. The LCD Screen will prompt for a 6-digit code. "04" for user number 4. CHANGING USER CODES...
User Manual - Page 18

... performed. Enter your installer. 16 NX-148E-CF Master code? Sched arm only? Output 3 ? Step 2 Press r 7 . Wait a few minutes and repeat step 2 to silence the keypad. Open / Close Rprt? Output 2 ? Step 3 If the keypad begins beeping, the reset did not execute properly. Arm only? Step 4 NOTE: The LCD will apply to the user code you wish to re-establish...
User Manual - Page 19

... control panel has an event log that this event is not programmed to the oldest, press the - The display contains the following information. Refer to Appendix A on page 25 for a list of Partition 3 on September 25th at 5:27 p.m. The LCD will now show the most recent to be retrieved using a master code. The LCD screen...
User Manual - Page 20

... is turned on , the chime light will be displayed with the current hour flashing. If the chime is on or off and produce a momentary ding-dong sound. 18 NX-148E-CF The...LCD Screen will toggle the chime feature on/off by pressing the [CHIME] key. Step 3 Use the • - Step 5 Repeat Steps 3 and 4 until the entire time and date are set. If the chime is off . Step 2 Enter [master code...
User Manual - Page 22

...LCD screen. down scroll key. Press [STAY] during the exit delay to be armed/disarmed. ARMING AND DISARMING MULTIPLE PARTITIONS To arm/disarm multiple partitions, enter a code... and disarmed conditions, press [r][Area number]. LCD DISPLAY FOR AREA TOP LINE OVER BOTTOM LINE...area is flashing on the LCD screen. NOTE: If a...arm, this code has Arm º access. System Ready Type code to arm...
User Manual - Page 23

OPERATING INDIVIDUAL AREAS IN THE MULTI-PARTITION MODE Enter a code that is running, it can be replaced with the authority for the area you wish to arm Area 5 is selected and Area 5 is selected. The LCD keypad will appear. To exit the individual partition mode, enter [#]-[#]. To operate an individual area, enter the number...
User Manual - Page 24

... trouble condition exists. 22 NX-148E-CF Pulses when the armed status changes and the AC power is in system). Entering a valid code will silence the keypad sounder when it is disarmed...exit delay; Pulses when one or more of the exit delay. Entering code will not change when entering a code to silence a pulsing keypad sounder. Pulses when a day zone is violated while the system is ...
User Manual - Page 26

... zone. A radio receiver is being jammed. (Not applicable to all controls.) An expansion device or keypad is experiencing some form of trouble (probably wiring). Press [r] to the control panel. A zone is not reporting to identify the zone. 24 NX-148E-CF A wireless device has a low battery. Press [r] to the control. A short circuit of an...
User Manual - Page 28

...In Service Start Service End Code Entry First Open Last Close Sprnklr Clock Set RF... in the stay mode. Instant sprinkler supervisory report Clock has been reset. Bell and/or communicator test while system is disarmed and the Cancel...when the first partition is jammed A smoke detector requires cleaning. 26 NX-148E-CF Test has been ended. Technician is on an expander auxiliary output...
User Manual - Page 32

NX-148E-CF USERS MANUAL NX148ECFUB03 REV B (MAY2003)

Similar Questions

Ask a New Question
Use the box below to post a new question about this GE product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

GE Manuals

Find free GE NX-148E - Security NetworX LCD Keypad manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

GE Reviews

View thousands of GE user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete GE customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed GE customer service rankings, employee comments and much more from our sister site.

GE Recalls

Find comprehensive GE recall information updated hourly on RecallOwl.com.