I have owned the security system since 2007. It appears to not have changed by looking at the new ones for sale. Also, how do you take off the door? Thanks, Bernie

Current Answers

Answer #1: Posted by cooltechagent on April 15th, 2014 5:39 PM
This answer was accepted by the poster of the original question.
cooltechagent

Member since:
January 6th, 2014

Points: 1,072,690
1,110
points
Contact this number to order the parts:

800-762-7846




Thanks,
CoolAgent

Related GE NX-148E-RF Manual Pages

User Manual - Page 2

COMMERCIAL FIRE SYSTEM LCD KEYPAD Model NX-148E-CF READY light is "on" when the system is "on" when armed, "off" when ...EMERGENCY ACTIVATION KEYS NUMERIC CODE ENTRY KEYS The appropriate stickers should be removed or replaced when desired. FIRE light is detachable and can be applied on the keypad door for the Emergency Activation keys that are programmed to indicate a trouble condition with...
User Manual - Page 3

... or Silence Alarm: Enter your system is not partitioned. To Quick Arm and Exit: Press "Exit" key. Reset Smoke Detector and Panel Reset: Press 7 NX-148E-CF 1 Door Chime: Press "Chime" key to find out how your user code. Installing/Service Company For Service Call Central Station This system is is programmed. Check...
User Manual - Page 5

EVENT LOG 25 EMERGENCY EVACUATION PLANS 27 NX-148E-CF 3 TABLE OF CONTENTS GLOSSARY OF TERMS 4 UNDERSTANDING THE LIGHTS 6 KEYPAD FUNCTIONS 7 Arming Your System In The "...Change Languages 14 Changing User Codes 15 Assigning User Code Authority Levels 15 Reset Function 16 Reading The Event Log 17 Adjusting The View / Brightness Of The LCD 17 Setting The System Clock 18 Using The Door...
User Manual - Page 6

... YOUR SYSTEM, CONTACT THE INSTALLING COMPANY. 4 NX-148E-CF Use qualified security professionals to failure or malfunction. Understanding what the...security system which is connected and adequately charged. 8. The system must always be loud enough, wired correctly, and properly placed to provide notification of security devices attached to plug in electronic sounder. The LCD keypad...
User Manual - Page 8

...changed from instant to disarm the system if the exit light is in Stay Mode", page 8.) The doors can be enabled. (See "Cancel/Abort Feature" on page 10.) Chime Light The chime light is "on if the primary power is armed. 6 NX-148E...Message The LCD display will cause the cancel light to arm because of the exit delay as a warning that a fire zone is flashing in this keypad's partition ...
User Manual - Page 10

...If "Auto Instant" is inside the premise and wants protection around the perimeter. The LCD display will be violated without an alarm. ARMING YOUR SYSTEM IN THE "STAY" MODE...light will illuminate indicating that the entry/exit doors no AC power. If Auto Bypass is off, you do NOT have an entry delay. The security system will illuminate if any zones are ...delay. 8 NX-148E-CF
User Manual - Page 11

... an alarm will not disarm the security system. You may be used for ARMING ONLY, and...the duration of the designated Entry/Exit doors, the keypad control will stop. DISARMING YOUR SYSTEM...one of the entry delay time, or until you to The red armed light will go off (toggle) a delay on Entry/Exit doors. Leave the building immediately and call your absence. CHANGING...
User Manual - Page 12

...a code followed by the [CANCEL] key while this light is in the disarmed state. Step 2 When the LCD prompts for zone 112.) Step 5 Step 6 Step 7 Press the [BYPASS] key again. Step 4 Enter the... The cancel feature must be enabled. BYPASSING ZONES If you wish to bypass one or more zones, this viewing mode. 10 NX-148E-CF NOTE: The abort feature must be bypassed. Procedure #1 If you wish ...
User Manual - Page 14

... CHIME=Walk Test 7=Detector Reset EXIT=Silent Exit 90=Log Review 91=View Settings 97=Set Date/Time 12 NX-148E-CF The following list of functions and the corresponding numbers associated with your security system will scroll automatically. Step 1 Press r The display will now begin scrolling though a list of menu selections will...
User Manual - Page 16

... the second language. The LCD keypad is pressed. Step 2 Repeat Step 1 to revert to turn the X-10 device "On" or press the - The LCD screen will perform a test of the display it will prompt you to "Select Light Number 0 - 9". Step 3 Press the • to the first language. 14 NX-148E-CF LIGHT CONTROL FOR X-10...
User Manual - Page 17

...changing the current code, you for user number 4. The LCD keypad will now prompt for this user. Stars (r) represent blanks. The LCD Screen will display the current code for a code. Step 2 Enter [master code]. The LCD Screen will beep 3 times. NX148E-CF 15 CHANGING...access to change and enter the correct number. Step 6 Press # while the LCD screen is prompting for a new user to ...
User Manual - Page 18

... » DO NOT CHANGE THIS SEGMENT! (These are... the system if it is used ? Output 2 ? If these messages appear on the keypad, and the display will apply to the user code you for the next...LCD screen, press the [r] key until you wish to re-establish user access to the partition, press the partition number again. Resets have now been performed. Enter your installer. 16 NX-148E...
User Manual - Page 20

Step 3 Use the • - USING THE DOOR CHIME FEATURE The door chime is turned on or off . If the chime is off, the chime light will be ...on /off and produce a momentary ding-dong sound. 18 NX-148E-CF Each press of week, date, month, and year. Step 5 Repeat Steps 3 and 4 until the entire time and date are set. The LCD Screen will toggle the chime feature on , the chime light...
User Manual - Page 21

...area has a Fire Trouble condition. Press [#] to the NX-8 control panel. The fire light will flash if ANY... and the keypad resides in one area has a Fire condition. FIRE will illuminate if ANY one partition, your keypad will illuminate ... IN THE PARTITIONING MASTER MODE ARMED and READY STATUS The LCD screen will illuminate and remain constant until the central station has...
User Manual - Page 22

... ready to bypass all of these areas, press the - The numbers on the LCD screen. Refer to which this display will appear on the top line represent the 12-45-78 --3 67- To toggle a...in the exit delay. The following section. 20 NX-148E-CF NOTE: If a number is flashing on the Ready line, that area is ready to be Force Armed. LCD DISPLAY FOR AREA TOP LINE OVER BOTTOM LINE ...
User Manual - Page 23

... is running, it can be replaced with the word "Area #". To operate an individual area, enter the number of this code will be silenced by this feature. All keys and functions entered will only work if an individual partition is ready to operate. The LCD keypad will appear on the LCD screen. 12-4-78 Disarm...
User Manual - Page 24

...will not change when entering a code to silence a pulsing keypad sounder. ...one or more of the following reasons: Beeps for all keypresses. Entering a valid code will suppress the sounder for 12 hours. KEYPAD CONTROL TONES (BEEPS) A sounder is built into the keypad...keypad sounder when it is pulsing. and beeps 1 second at the end of your installer if a trouble condition exists. 22 NX-148E...
User Manual - Page 26

... Expansion Box tamper Expansion Low Battery Expansion Over-current Expansion Power trouble Expansion Siren trouble Expansion RF Jammed Expansion Trouble Zone Lost, Press r Zone Low Batt, Press r Zone Tamper, Press...expansion device or keypad is tampered. A wireless or multiplexed zone device is not on the bell or siren circuit. Press [r] to identify the zone. 24 NX-148E-CF Press ...
User Manual - Page 28

...Start Service End Code Entry First Open Last Close Sprnklr Clock Set RF Jammed CleanMe Expansion Event Partial Arm Listen In Service Start Service End Code Entry First ...is off site. A trip has occurred on site. Technician is jammed A smoke detector requires cleaning. 26 NX-148E-CF An expansion module created an undefined event. The first zone of an alarm. The exit delay has ...
User Manual - Page 32

NX-148E-CF USERS MANUAL NX148ECFUB03 REV B (MAY2003)

Similar Questions

Ge Nx-148e
Where is location of support backup battery?
(Posted by tgraddy 11 years ago)
Resetting/reprogramming Ge Nx-8 Security System.
I have a GE NX-8 security system and need help resetting the panel. I want to start over from scratc...
(Posted by Anonymous-37297 12 years ago)
Ask a New Question
Use the box below to post a new question about this GE product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

GE Manuals

Find free GE NX-148E-RF - Security NetworX NX-8E System manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

GE Reviews

View thousands of GE user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete GE customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed GE customer service rankings, employee comments and much more from our sister site.

GE Recalls

Find comprehensive GE recall information updated hourly on RecallOwl.com.