Get support for GE NX-148E - Security NetworX LCD Keypad

GE NX-148E Support Question

GE NX-148E Support Question

Find answers below for this question about GE NX-148E - Security NetworX LCD Keypad.
Need a GE NX-148E manual? We have 1 online manual for this item!
Question posted by hellasko on April 22nd, 2014

How To Program Zone Names Networx Nx-148e

The person who posted this question about this GE product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related GE NX-148E Manual Pages

User Manual - Page 2

ARMED light is "on the keypad door for the Emergency Activation keys that are programmed to work with your system. PROGRAMMABLE EMERGENCY ACTIVATION KEYS NUMERIC CODE ENTRY KEYS The appropriate stickers should be removed or replaced when desired. COMMERCIAL FIRE SYSTEM LCD KEYPAD Model NX-148E-CF READY light is "on " when AC power is present, flashes...
User Manual - Page 3

... to find out how your installation company to activate. EMERGENCY ACTIVATION KEYS (check if enabled) Fire Auxiliary Emergency Police PROGRAMMED FUNCTIONS Abort Delay (s) Battery Test Cancel Alarm Chime Forced Arming (s) Group Bypass (s) Quick Arm (s) Re Exit Siren...For Service Call Central Station This system is is programmed. Reset Smoke Detector and Panel Reset: Press 7 NX-148E-CF 1
User Manual - Page 5

... The View / Brightness Of The LCD 17 Setting The System Clock 18 Using The Door Chime Feature 18 PARTITIONED SYSTEMS OPERATION 19 Lights In Partitioning Master Mode 19 Displays In The Partitioning Master Mode 19 KEYPAD CONTROL TONES (BEEPS 22 SERVICE DISPLAY 23 APPENDIX A - EVENT LOG 25 EMERGENCY EVACUATION PLANS 27 NX-148E-CF 3
User Manual - Page 6

... so programmed, you to a telephone keypad. It may be able to this system. 2. IF YOU DO NOT UNDERSTAND ANY PORTION OF THIS MANUAL, OR IF YOU HAVE ANY QUESTIONS ABOUT YOUR SYSTEM, CONTACT THE INSTALLING COMPANY. 4 NX-148E-CF YOU SHOULD BE AWARE OF THE FOLLOWING FACTS WHEN PREPARING A SAFETY/SECURITY PLAN FOR YOUR HOME/BUSINESS...
User Manual - Page 7

... only) as programmed by the installing company. NOTE: Those zones that can program other user codes... that allows the keypad to the central...zones open. Group Bypass: An option that allows the user to be sent to sound a ding-dong whenever an entry/exit door is ready to the central station. NX148E-CF 5 Quick Arm: An option that allows you to turn on (ARM) the security...
User Manual - Page 8

...zones are bypassed. Instant Message The LCD display will read "Instant" when the entry/exit door(s) have no zones are bypassed. If the bypass light is "on . Entering a code followed by pressing the [STAY] key when the system is armed. 6 NX-148E... because of the exit delay as a warning that a fire zone is in this keypad's partition is "on if the primary power is flashing in Stay...
User Manual - Page 10

.... (Optional, if programmed.) If "Auto Bypass" is enabled, omit Step 4. The LCD display will not arm...zone(s) will illuminate if any zones are as follows: Step 1 Close all interior zones will be violated without an alarm. The security system will read "Instant", indicating that zone can be on or flashing. If any zone (s) have an entry System Armed Instant delay. 8 NX-148E...
User Manual - Page 11

..." message will turn on/off (toggle) all interior zones are not bypassed, the stay light will sound a continuous... one of the designated Entry/Exit doors, the keypad control will extinguish. NOTE: If the red armed...programmed.) When armed, pressing the [EXIT] key will start the Exit delay, enabling you to turn on/off and Disarm the tone will not disarm the security system. The security...
User Manual - Page 12

...NX-148E-CF Press the # key to exit the Bypass Mode. It will stop the communication process. Step 4 Enter the zone you know the number of the zone to bypass. (Example: Press 6 for zone 6 or 1 1 2 for zone..., if programmed), enter your user code. NOTE: The abort feature must be enabled. Step 2 When the LCD prompts for any other zone(s) that need to bypass one or more zones, this ...
User Manual - Page 14

...to the monitoring center. If your security system will be sent to that... listed below reflects the available functions. ù=Zone Review 0=Set Tone 1=Master Mode 2=Service Check...View Settings 97=Set Date/Time 12 NX-148E-CF Hint: If you can activate the... programmed to be transmitted to that particular function. Step 1 Press r The display will scroll automatically. If programmed,...
User Manual - Page 15

... tone º sounder to exit the alarm memory. the zone Alarm Memory ZONE 1 1 Step 3 Press [#] to lower tones. Step 1 Press r 4 4 . The LCD Screen will be performed as programmed. VIEW ALARM MEMORY Step 1 Press r 3 to browse through the descriptions. scroll keys to display the zone(s) on the keypad that created the last alarm. The test will display...
User Manual - Page 16

..."Off". The LCD keypad is pressed. Step 3 Press the • to exit from each keypad. Step 4 The LCD screen will again prompt you to ten X-10 devices from the X-10 menu. The LCD screen will prompt you to control up to switch between the two languages programmed in your keypad. Step 1 ... the right side of the X-10 device you to control. to the first language. 14 NX-148E-CF
User Manual - Page 17

... the current code, you must have access to which the other person has access. The LCD keypad will prompt for a code. If it rejects the code because of the partitions to all... authority. Always use leading zeros when necessary, i.e. The LCD Screen will display the current code for a new user to exit Code Programming, ASSIGNING USER CODE AUTHORITY LEVELS Assign authority levels to add...
User Manual - Page 18

.... Step 3 If the keypad begins beeping, the reset did not execute properly. Wait a few minutes and repeat step 2 to attempt another user code needs to be programmed, return to Step 3. Open...LCD screen, press the [r] key until you return to the prompt for the next user code. Step 2 Press r 7 . Enter your installer. 16 NX-148E-CF Sched arm only? If these messages appear on the keypad...
User Manual - Page 20

... of the [CHIME] key will toggle the chime feature on or off and produce a momentary ding-dong sound. 18 NX-148E-CF The time and date will be illuminated. Step 4 Press the r key to move to select the proper hour.... light will be off , the chime light will prompt for a code. The LCD Screen will be displayed with the current hour flashing. SETTING THE SYSTEM CLOCK Step 1 Enter r 9 7 .
User Manual - Page 22

Disarm º disarmed areas to bypass all interior zones in the exit delay. LCD DISPLAY FOR AREA TOP LINE OVER BOTTOM LINE Blank Blank Dash (-) Dash (-) Flashing Area # Dash (-) Dash (-) Flashing Area # Area # Dash (-) Dash (-)...-678 This display is reflecting all 8 areas are Ready, and Area 5 is disarmed, [r] [4] will arm it. The following section. 20 NX-148E-CF If Area 4 is disarmed.
User Manual - Page 24

...Entering code will not change when entering a code to silence a pulsing keypad sounder. KEYPAD CONTROL TONES (BEEPS) A sounder is built into the keypad and may sound for any of the following conditions are detected: Zone or Box Tamper, Low Battery, AC Power Fail, or Expander trouble..... Beeps 3 times for the last 10 seconds of your installer if a trouble condition exists. 22 NX-148E-CF
User Manual - Page 26

... trouble Expansion RF Jammed Expansion Trouble Zone Lost, Press r Zone Low Batt, Press r Zone Tamper, Press r Zone Trouble, Press r A box containing an expansion device has been opened. Press [r] to identify the tampered zone. A wireless device has a low battery. Press [r] to identify the zone. 24 NX-148E-CF Press [r] to identify the zone. A radio receiver is being jammed...
User Manual - Page 28

...on site. A zone "Walk-Test" mode has been activated. Technician is on an expander auxiliary output. Reports when the first partition is jammed A smoke detector requires cleaning. 26 NX-148E-CF A wireless ... in function has been activated. A code has been entered. Communication of a cross zone has been tripped (log only). An expansion module created an undefined event. Instant sprinkler...
User Manual - Page 32

NX-148E-CF USERS MANUAL NX148ECFUB03 REV B (MAY2003)

Similar Questions

Where Can I Buy A Swing Down Door Replacement For A Ge Nx-148e Lcd Keypad?
I have owned the security system since 2007. It appears to not have changed by looking at the new on...
(Posted by btestrake 10 years ago)
Ge Networx Nx 148e Security System
Just bought a foreclosed home & it has two security system panels, one on each level. I do not k...
(Posted by Meadowsa 10 years ago)
Ask a New Question
Use the box below to post a new question about this GE product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

GE Manuals

Find free GE NX-148E - Security NetworX LCD Keypad manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

GE Reviews

View thousands of GE user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete GE customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed GE customer service rankings, employee comments and much more from our sister site.

GE Recalls

Find comprehensive GE recall information updated hourly on RecallOwl.com.