Get support for Dell PowerVault NX3100

Dell PowerVault NX3100 Support Question

Dell PowerVault NX3100 Support Question

Find answers below for this question about Dell PowerVault NX3100.
Need a Dell PowerVault NX3100 manual? We have 8 online manuals for this item!
Question posted by lswanstev on May 6th, 2014

Powervault Nx3100 How To Add Hdd To Raid

The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Dell PowerVault NX3100 Manual Pages

Glossary - Page 3

...activity can optionally use a FAT file system structure. Input/output. In general, I /O - A remote access controller that implements communication between the system board and storage devices. A type of file storage. FSB - Front-side bus. G - Gb - expansion-card connector - A connector on and running. A video mode that can be programmed and reprogrammed using a software utility...
Glossary - Page 5

... the data. See also striping and RAID. Managed object format is installed or... memory key - MOF - A device that is an ASCII file that connects to serve specific storage needs. Media Access Control address.... managed system - Megabyte(s); 1,048,576 bytes. A specific location, usually expressed as integrated memory (ROM and RAM) and add...
Glossary - Page 7

...Self-Monitoring Analysis and Reporting Technology. Redundant array of RAID include RAID 0, RAID 1, RAID 5, RAID 10, and RAID 50. readme file - Your system contains some programs essential to be locally attached. Serial Advanced Technology Attachment. A standard interface between the system board and storage devices. SDRAM - service tag - Random-access memory. A registered DDR3 memory...
User Manual - Page 8

... Server 2008, Basic Edition, x64 • Microsoft Windows Storage Server 2008, Workgroup Edition, x64 • Microsoft Windows Storage Server 2008, Standard Edition, x64 Supported Systems • Dell PowerVault NX200 • Dell PowerVault NX300 • Dell PowerVault NX3000 • Dell PowerVault NX3100 Configurations Pre-Installed on Your System Roles and Services • File Services...
User Manual - Page 29

...Windows 2008 Domain Controller and install Identity Management for Unix using Server Manager Roles Add Role Services. Modify the UID, GID, shell, home directory, and domain details (captured ... the UNIX user name and group. 4 Add the user to the group created in the previous step. 5 Select the newly-created user, go to PowerVault NAS Windows Storage Server 2008 (NFS) Server. 8 Click...
Troubleshooting Guide - Page 5

...RAID 1 (Dell PowerVault NX300, original factory it defaults to the RAID 5 NX3000, and NX3100) or RAID 5 configuration. configuration. (PowerVault NX200), create a virtual disk with the desired RAID configuration, LUN ID 0, and a capacity of the RAID... 0 of 80 GB or more. 4 Reboot the Dell PowerVault Network Attached Storage (NAS) using the operating system reinstallation media or DVD. ...
iSCSI Deployment Guide - Page 7

... document the iSCSI Initiator is referred to as a block storage device. Introduction This document provides information about creating an iSCSI Target and establishing connection with a Microsoft® iSCSI Initiator • End-to-end iSCSI configuration: - Detailed instructions on the Dell™ PowerVaultstorage system as the Initiator and the iSCSI Software Target is...
iSCSI Deployment Guide - Page 14

...PowerVault NAS Storage System Initiator setup Target setup Log on from Initiator Configure the Microsoft iSCSI Initiator with the IP address of Target creation. 14 Setup Steps for iSCSI traffic (see Figure 1-1). 5 Click OK. The following options are displayed-iSCSI Targets, Devices...tab. 3 Select Add portal. 4 Add the IP address of one of the NICs on the PowerVault storage system that is ...
iSCSI Deployment Guide - Page 18

...iSCSI Initiator→ Discovery tab→ Add iSNS. 2 Add the IP address of the iSNS server and click OK (see "Appendix" on Initiator (host) or Target (PowerVault storage solution). NOTE: Do not install .... 8 To initialize and configure the iSCSI device as an iSNS server. 2 Ensure that the Initiator and the Target are on the storage array for creating virtual disks for iSCSI Target...
iSCSI Deployment Guide - Page 19

..., select the iSNS tab and add the iSNS server information (DNS Name or IP address). Configuring the Initiator-Target Connection From Initiator (Host) For information about configuring the Initiator-Target connection, see "Log on Configuring the Initiator-Target Connection From Initiator (Host)" on from Initiator 1 From the PowerVault storage system, go to ensure...
iSCSI Deployment Guide - Page 21

...a few LUNs and reserve storage space to use of the host application. The following section provides step-by default. You can add an optional additional NIC. NOTE...device-The PowerVault NAS storage solution is designed for the iSCSI Initiator, Target, and establishing connections. The PowerVault NAS storage system is configured to create virtual disks for iSCSI Targets. The PowerVault...
iSCSI Deployment Guide - Page 22

...PowerVault NAS storage solution runs on a Microsoft Windows® operating system based platform. NOTE: Create iSCSI Targets only after configuring the Discovery tab in the iSCSI Initiator To configure dedicated iSCSI NICs: a Go to provision the storage... so on the PowerVault NAS storage solution are listed.... configured in the PowerVault storage solution- c In...PowerVault NAS Management Console→...
iSCSI Deployment Guide - Page 23

...from the list. In the Advanced Identifier screen, click Add, and enter the Identifier type and the specific identifying ...can manually enter the IQN or use the Browse option to the storage that is displayed. d In the iSCSI initiators identifiers screen, ... an iSCSI Target: Figure 3-1. Creating iSCSI Targets a In the PowerVault NAS Management Console, right-click iSCSI Targets on the left pane ...
iSCSI Deployment Guide - Page 24

...PowerVault NAS Management Console now displays the newly-created iSCSI Target. The iSCSI Initiators identify these two virtual disks as the Identifier. Create the virtual disk on the internal disk volume (the RAID...The PowerVault NAS Management Console also displays the devices available...from the attached storage array) that ...Advanced Identifier→ AddAdd/Edit Identifier→...
iSCSI Deployment Guide - Page 25

... Details 25 g Click Add and enter the iSCSI Target... GB on the device (RAID volume) that is... iSCSI Target device view displays ...Devices You can create or delete virtual disks using the following options in PowerVault...PowerVault NAS Management Console displays the virtual disks associated with a .vhd extension. This feature is available for the application host to virtual disks (devices...
iSCSI Deployment Guide - Page 49

... to the Targets. iSNS server performs Target Discovery. • Similarly, PowerVault NAS storage system (Target) can view all Target Devices that are listed in step a is listed. The iSNS server screen ... or later and go to PowerVault NAS Management Console→ Microsoft iSCSI Software Target→ right-click and select Properties→ iSNS tab and add iSNS server IP address or DNS...
Getting Started Guide - Page 3

Dell™ PowerVaultNX3100 Systems Getting Started With Your System Regulatory Model E13S Series
Setting Up Your Dell PowerVault NAS Solution - Page 1

...and remotely access the NAS system using your system, please read the updates first because they often supersede information in other documents. 1 Dell PowerVault NX3100 storage system 4 2 5 3 6 Dell PowerVault MD12xx storage array (optional) 1. Using a Keyboard, Video, and Mouse Connect a keyboard, monitor, and mouse directly to In-0 on support.dell.com/manuals. For information about...
Setting Up Your Dell PowerVault NAS Solution - Page 2

... a Server Message Block (SMB) share preconfigured on your system. To access the utility share, type \\D\NASUtils\ where is complete, you will be prompted to the PowerVault NX3100 storage system. Once the wizard is the Service Tag number located on to the secure port, 1311, of Dell Inc. The utility share allows you to...
Hardware Owner's Manual - Page 106

... and simple repairs as authorized in your product documentation, or as a boot device, security key, or mass storage device. CAUTION: Many repairs may only be enabled by the Internal USB Port option... boot image and then specify the USB memory key in the boot sequence in the Integrated Devices screen of the card. 3 Press inward on your system configuration. Removing a VFlash Media ...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Dell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dell Manuals

Find free Dell PowerVault NX3100 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dell Reviews

View thousands of Dell user reviews and customer ratings available at ReviewOwl.com.