Question posted by rfgabon on June 2nd, 2014

Where Is Memory Slot 6 On 2950

The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Dell PowerEdge 2950 Manual Pages

Installing a SATA Optical Drive - Page 4

... on the left side of the drive. 4 Installing a SATA Optical Drive Replacing a PowerEdge 2950 or 2970 Optical Drive NOTE: If you must be replaced with the drive tray provided with...it into the tray and press the drive down to the optical drive. PowerEdge 2970, 2950, and 1950 For PowerEdge 2970 and 2950 systems, the optical drive tray that shipped with the SATA drive installation kit...
Installing a SATA Optical Drive - Page 5

... drive. See Figure 1-2. Figure 1-1. Installing a SATA Optical Drive 5 Replacing the Optical Drive in a PowerEdge 2950 or 2970 System 2 1 3 4 5 6 7 1 optical drive 3 interposer 5 SATA power cable 7 optical drive carrier 2 interposer release latch 4 SATA cable 6 carrier latch Replacing a PowerEdge 1950 Optical Drive NOTE: The replacement drive tray provided in the side of the...
Installing a SATA Optical Drive - Page 7

... 2 1 3 4 6 5 1 SATA data cable 3 chipset shroud 5 SATA power cable 2 SATA_A connector on the system and attached peripherals. Installing a SATA Optical Drive 7 PowerEdge 2970 or 2950 1 Insert the optical drive tray into the system until it is fully inserted and locked into position. 2 Connect the SATA cable (the end with the ...
Installing a SATA Optical Drive - Page 8

... cable. See Figure 1-4. 7 Route the SATA cable along the top of the system until the bracket detaches from the chassis slots. 6 Route the SATA cable in the cable channel in the PowerEdge 2950 and 2970 1 2 3 4 5 1 SATA_B connector on the system board. Figure 1-4. See "Removing the Cooling Shroud" in your Hardware Owner's Manual. 5 Remove...
Information Update - Page 1

Dell™ PowerEdge2950 Systems Information Update
Information Update - Page 3

...and PowerEdge 2950 III Systems 9 System Board Replacement - New System Features 5 New Performance Features 5 New High-Efficiency Power Supply and Power Monitoring Features 5 New I/O and Storage Features 6 New Security Features 6 Optional Internal USB Memory Key 6 Installing the Optional Internal USB Memory Key 7 Support for 8-GB Memory Modules - Contents Non-Optimal Memory Configurations...
Information Update - Page 5

...is detected and the following message is displayed: Non-Optimal Memory Configuration Press F1 to the slowest speed in the system....voltage, and power utilization in the DIMM set for Setup NOTE: Mixing DIMMs of different speeds renders the memory configuration non-optimal. PowerEdge 2950 III - Information Update 5 New System Features New Performance Features • Two dual-core or quad-core...
Information Update - Page 9

... - Loading the latest BIOS version ensures that was shipped with a "III", your system. System Board Replacement - PowerEdge 2950 III Systems PowerEdge 2950 III systems have added support for 8-GB Memory Modules - Safeguarding Encrypted Data On PowerEdge 2950 III systems using Windows Server® 2008, you can use encryption programs, such as the BitLocker utility, to the 5100 series...
Information Update - Page 10

... Information Guide for complete information about safety precautions, working inside the system. The memory configuration Ensure that the memory does not support node modules are authorized to notify you can access the encrypted ...node for additional information interleaving cannot be for the PowerEdge 2950 III system and the probable cause and corrective action when the message appears.
Information Update - Page 15

... Status Messages Code N/A E1000 E1118 Text SYSTEM NAME FAILSAFE, Call Support CPU Temp Interface Causes Corrective Actions A 62-character string that can occur on the PowerEdge 2950 III system and the probable cause for each message. See "Using the System Setup Program" in the System Setup program. Information Update 15 The LCD...
Information Update - Page 24

... memory key where the test log file is saved. System Diagnostics Update In the Customize window of the system diagnostics, the Log output file pathname option enables you run the System Build and Update Utility, Microsoft® Windows® 2000 is supported by the PowerEdge 2950 and 2950 II systems, but not by the PowerEdge 2950...
Information Update - Page 27

目录 29 PowerEdge 2950 III 29 29 29 全新 I/O 30 30 内部 USB 30 USB 30 支持 8 GB PowerEdge 2950 III 32 PowerEdge 2950 II 和 PowerEdge 2950 III 32 32 33 LCD 37 40 Memory 40 CPU Information (CPU 42 Integrated Devices 42 System Security 44 Serial Communication 45 目录 27
Information Update - Page 29

POST Non-Optimal Memory Configuration Press F1 to continue or F2 for Setup (按 F1 F2 DIMM DIMM PowerEdge 2950 III 全新性能 Intel® Xeon® 5400 系列和 5300 8 GB BMC 信息更新 29
Information Update - Page 33

Memory configuration does not support Node Interleaving. Node Interleaving disabled! PCIe PCIe SAS No boot ... devices may not be available... RAC 卡"。 Invalid PCIe card found in the Internal_Storage slot! 表 1-1 列出了 PowerEdge 2950 III 表 1-1 信息 原因 纠正措施 Alert!
Information Update - Page 46

Microsoft Windows 2000 System Build and Update Utility Microsoft® Windows® 2000 将位于 Server OS Install PowerEdge 29502950 II PowerEdge 2950 III Customize Log output file pathname USB 46 信息更新
Information Update - Page 109

POST Non-Optimal Memory Configuration Press F1 to continue or F2 for Setup F1 F2 DIMM DIMM DIMM PowerEdge 2950 III Intel® Xeon® 5400 5300 2 個。 • 8 GB BMC 109
Information Update - Page 132

...; cat/sys/devices/system/cpu/cpuxx/cpufreq/scaling_ cur_freq • RHEL 3 9 Intel Xeon 54xx proc/cpuinfo RHEL 4 Microsoft Windows 2000 System Build and Update Utility Server OS Install OS OS Microsoft® Windows® 2000 PowerEdge 2950/2950 II OS PowerEdge 2950 III Customize Log output file pathname USB 132
Information Update - Page 137

POST Non-Optimal Memory Configuration Press F1 to continue or F2 for Setup F1 F2 DIMM DIMM PowerEdge 2950 III Intel® Xeon® 5400 5300 • 8GB BMC 137
Information Update - Page 142

...Invalid PCIe card found in the Internal_Storage slot! PCIe PCIe SAS 142 Memory configuration does not support Node Interleaving. DIMM !!*** Error: Remote Access Controller initialization failure *** RAC virtual USB devices may not be available... Node Interleaving disabled! 표 1-1 PowerEdge 2950 III 표 1-1 메시지 원인...
Information Update - Page 157

Microsoft Windows 2000 Microsoft® Windows® 2000 이 Server OS Install(서버 OS PowerEdge 2950 III 대신 PowerEdge 29502950 II Customize Log output file pathname USB 157

Similar Questions

Memory Slots Vacant ?
Hello Support! Is it possible to check without opening the Poerege R710 server to see how many memo...
(Posted by irfanhussaain 12 years ago)
Ask a New Question
Use the box below to post a new question about this Dell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dell Manuals

Find free Dell PowerEdge 2950 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dell Reviews

View thousands of Dell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls

Find comprehensive Dell recall information updated hourly on RecallOwl.com.