Dell PowerConnect 6224 Support Question
Find answers below for this question about Dell PowerConnect 6224.Need a Dell PowerConnect 6224 manual? We have 5 online manuals for this item!
Question posted by rafamGarenk on April 20th, 2014
How To Factory Reset Dell 6224
The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related Dell PowerConnect 6224 Manual Pages
Command Line Interface Guide - Page 1322
... type.
This field indicates the management preference value of the show supported switchtype [switchindex] command. console#show supported switchtype 1 Switch Type 0x73950001 Model Identifier 6224 Switch Description PowerConnect 6224 Management Preference 1 Expected Code Type 0x100b000 Supported Cards:
Card Index (CID 3 Model Identifier PCM8024 The following example displays the format...
Command Line Interface Guide - Page 1339
... not eligible for management.
The priority of one backup switch over another. (Range: 0-12)
Default Configuration The switch priority defaults to the hardware management preference value of a switch has been configured, it cannot be reset to become the Management Switch. System Management Commands
1339 The switch with the highest priority value is not affected by the...
User's Guide - Page 19
...: • 1U form factor, rack-mountable chassis design. • Support for PoE capability. The Dell PowerConnect 6224P adds support for RJ-45 or SFP interfaces. The Dell™ PowerConnect™ 6200 series are provided with hot swappable stack members. The Dell PowerConnect 6224 switch supports 24 1000Base-T copper ports and 4 "combo" ports for RJ-45 or SFP interfaces...
User's Guide - Page 59
...management port
DC power
AC power
Figure 4-7. Rear Panel
Each PowerConnect 6200 series switch provides an RS-232 maintenance port, on the rear of the switch. This serial connection can support a plug-in Dual 10GbE ..., CX4, or stacking modules
Dual 10G slots for XFP, CX4, or 10Gbase-T modules. PowerConnect 6224, 6248, and 6224F Rear Panel
Dual 10G slots for XFP, CX4, or stacking modules
...
User's Guide - Page 62
... this process until all of the switch rear. Power Supplies
The 6200 series switches have one on the switch to stacking port two on the top and bottom switches.
62
Hardware Description
For PoE switches, you can stack up to 12 PowerConnect 6224 and/or 6248 switches, supporting up to connect the switches. You can verify operation by observing...
User's Guide - Page 77
... Items such as addresses, versions, and dates may differ for each switch. Start operational code. 2 - Activate Backup Image 12 - Reset the system 10 - Retrieve event log using XMODEM 5 - Restore ... Menu] The boot process runs approximately 60 seconds. To return to factory defaults (delete config files) 11 - The following output displays an example configuration. Operational Code ...
User's Guide - Page 81
...switch:
• Establishes the initial privileged user account with default management VLAN ID=1.
After the initial set up more advanced security
considerations. The wizard configures one privileged user account during the set up , you may return later to use the local authentication setting only.
Configuring Dell PowerConnect...with only the default factory configuration. The Easy ...
User's Guide - Page 82
... be used for you return to configure security access for SNMPv3 (for the Easy Setup Wizard.
82
Configuring Dell PowerConnect The set -up wizard. The next time the system reboots you reset the switch to the factory-default settings. You may include spaces. If it is configured, the default access level is activated. Once saved...
User's Guide - Page 97
... the following command:
console#update bootcode
Update bootcode and reset (Y/N)? 2.
Update Bootcode Use the update bootcode command to reboot the switch. For each switch, the bootcode is completed. To update the bootcode for one switch, specify the unit in the command (as shown in 10 seconds then
operational code will start.
1 - Select (1, 2):
Configuring Dell PowerConnect
97
User's Guide - Page 98
...29 10:15:36 2008
Uncompressing.....
50%
100%
98
Configuring Dell PowerConnect The following sections describe the Boot menu options. Display operational code vital product data 6 - Start Operational Code Use option 1 to factory defaults (delete config files) 11 - Start operational code 2 - Reset the system 10 -
Change baud rate 3 - Delete backup image 9 - Activate...
User's Guide - Page 103
... action is selected. Restore Configuration to Factory Defaults Use option 10 to load using... backup when this option is confirmed with a Y/N question before executing the command. image2 activated.
2. To reset the system from the Boot Menu. The boot process starts over. Boot Sequence can then be started by selecting... To activate the backup image: 1.
Configuring Dell PowerConnect
103
Getting Started Guide - Page 21
PC 6248
Figure 1-3. PC 6224
Figure 1-2. Front Panels and LEDs
This appendix describes the front panels and LEDs of the Dell PowerConnect PC6224, PC6248, PC6224P, PC6248P, and PC6224F systems.
Front Panels
The front panels of the PowerConnect 6200 series systems are shown in the figures below. PC 6224P
Getting Started Guide
19 Figure 1-1.
Getting Started Guide - Page 266
show stack-port counters show stack-port diag show switch
show supported switchtype
LED
LED Dell Power Connect PC6248P ,PC6224P ,PC6248 , PC6224ו.PC6224F -
PowerConnect 6200
PC 6224
1-1
PC 6248
2-1...
Release Notes - Page 1
Dell™ PowerConnect™ 6224/6224F/6224P/6248/6248P
PowerConnect 6224/6224F/6224P/6248/6248P Release Notes
Date: May 2010 System Firmware Version 3.2.0.6
Information in this document is subject to either the entity claiming the marks and names or their products. Intel and Pentium are registered trademarks and Celeron is a trademark of Dell. This document may be...
Release Notes - Page 3
...Release Date May 2010
Firmware Upgrade
NOTE: Version 3.2 includes improvements to update the boot code AND firmware. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes
Introduction
This document provides specific information for the Dell PowerConnect 6200 Series switches, firmware version 3.2.0.6. NOTE: The PC6200 switches when stacked require that this release note be installed on every...
Release Notes - Page 4
... PowerConnect 62xx device that is not supported. NOTE: OMNM 4.1 will not discover the switches ...Dell™ PowerConnect™ 6200 Series Configuration Guide. Firmware Downgrade
Downgrading from 3.2.0.6 to a backup location before performing this firmware. Denotes a major version number. Hardware Supported
PowerConnect 6224 PowerConnect 6248 PowerConnect 6224F PowerConnect 6224P PowerConnect...
Release Notes - Page 5
...configurable message of operation is configurable via an HTTP session. System Firmware Version 3.2.0.6
Page 3 PowerConnect 6224/6224F/6224P/6248/6248P Release Notes
Added Functionality in this option is a string, it can... or software fault on the console. When the management unit fails, only the management switch needs to be unique.
¾ HTTP Download
Allow users to download files via the ...
Release Notes - Page 25
... required when resetting the spanning... motd acknowledge' is executed.
Default: From the factory the ports are all configured as either an ethernet.... Default: The switch remains in Interface Config Mode to the Dell™ PowerConnect™ 6200 Series...PowerConnect 6224/6224F/6224P/6248/6248P Release Notes
RADIUS Accounting Servers
Title radius-server host acct
Description The switches...
Release Notes - Page 27
... Read-only).
Workaround It is applied correctly.
If the configuration is saved and the switch is reset, the configuration is recommended that all user interface sessions being inaccessible until the user acknowledges the banner of a LAG. None. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes
Known Issues
Summary Non-configuration file getting read an...
Configuration Guide - Page 54
...
Enables L4 port number checking. Overview Denial of the switch - Dell tested the switch software with Nessus. There are 6 available types of ...Switching Configuration Nessus is represented by a dos-control command keyword.
Enables TCP flag checking. console(config)#dos-control ? Each type of attack is a widelyused vulnerability assessment tool. • PowerConnect...
Similar Questions
How To Preform A Factory Reset On A Dell Powerconnect 3548 Switch
(Posted by joelMa 10 years ago)
How To Factory Reset Powerconnect 6224 From Stack
(Posted by batwe 10 years ago)