Get support for Brother International MFC-9460CDN

Brother International MFC-9460CDN Support Question

Brother International MFC-9460CDN Support Question

Find answers below for this question about Brother International MFC-9460CDN.
Need a Brother International MFC-9460CDN manual? We have 6 online manuals for this item!
Question posted by Chasere on May 18th, 2014

Video Of How To Clean Drum Unit Corona Wire On Brother Mfc 9460cdn

The person who posted this question about this Brother International product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Brother International MFC-9460CDN Manual Pages

Advanced Users Manual - English - Page 5

... edge flip 51 Advanced Duplex Copy (short edge flip 53 A Routine maintenance 55 Cleaning and checking the machine 55 Cleaning the outside of the machine 55 Cleaning the scanner 56 Cleaning the laser scanner windows 57 Cleaning the corona wires 61 Cleaning the drum unit 65 Cleaning the paper pick-up rollers 71 Calibration ...72 Auto Registration 73 Manual Registration 73...
Advanced Users Manual - English - Page 67

A 61 Pull the drum unit out until it stops. Cleaning the corona wires A If you have print quality problems, clean the four corona wires as follows: a Press the front cover release button and then open the front cover. Routine maintenance b Hold the green handle of the drum unit.
Advanced Users Manual - English - Page 69

If you do not, printed pages may have a vertical stripe. e Clean the corona wire inside the drum unit by gently sliding the green tab from left several times. g Repeat steps d to f to left to right and right to clean each of three remaining corona wires. 63 Routine maintenance f Close the corona wire cover. 1 A Note Be sure to return the tab to the home position (a) (1).
Advanced Users Manual - English - Page 98

...credit card numbers 39 dial prefix 5 groups (broadcasting 19 restricting dialing 13 Drum unit checking (remaining life 74 cleaning 61, 65 Dual access 18 Duplex copy 51 E Enlarge/Reduce key 44... memory 22 fax storage 27 jobs awaiting redial 22 remote fax options 30 Cleaning corona wires 61 drum unit 65 laser scanner windows 57 scanner 56 Connecting two-line external TAD or telephone ..........
Users Manual - English - Page 30

... WAIVED. BROTHER LASER PRINTER / MULTIFUNCTION CENTER®...drum units, OPC belts, fixing units, print heads, paper feed rollers, transfer rolls, cleaning rollers, waste toner packs, oil bottles) or damage caused by anyone else involved in Canada. Improper packaging may also have other than a Brother Authorized Service Representative, or if shipped out of the Laser Printer/MFC...
Users Manual - English - Page 34

... the scan key 56 Scanning using a scanner driver 57 A Routine maintenance 58 Replacing the consumable items 58 Replacing a Toner cartridge 62 Cleaning the corona wires 68 Replacing the drum unit 72 Replacing the belt unit 79 Replacing the waste toner box 85 B Troubleshooting 92 Error and maintenance messages 92 Transferring your faxes or Fax Journal report...
Users Manual - English - Page 102

Routine maintenance f Clean the corona wire inside the drum unit by gently sliding the green tab from left to right and right to left several times. 1 1 Note Be sure to return the tab to release the latches of the corona wire cover (1), and then open the cover. A 65 If you do not, printed pages may have a vertical stripe. e Push to the home position (a) (1).
Users Manual - English - Page 103

... to the machine and/or may be damaged. • Brother strongly recommends that you DO NOT refill the toner cartridge provided with your investment and obtain premium performance from side to side several times to use of three remaining corona wires. g Close the corona wire cover. IMPORTANT • Wait to clean each of Genuine Brother Supplies. 66
Users Manual - English - Page 105

.... m Close the front cover of the machine. Note After you have print quality problems, clean the four corona wires as follows: a Press the front cover release button and then open the front cover until it stops. l Push the drum unit in until the LCD clears the Please Wait message and returns to Ready mode. 68
Users Manual - English - Page 107

If you do not, printed pages may have a vertical stripe. 70 e Clean the corona wire inside the drum unit by gently sliding the green tab from left to right and right to left several times. 1 1 Note Be sure to return the tab to release the latches of the corona wire cover (1), and then open the cover. d Push to the home position (a) (1).
Users Manual - English - Page 108

... toner cartridges. Cyan Y - Magenta K - Black 71 Routine maintenance h Hold the handle of M three remaining corona wires. f Close the corona wire cover. C g Repeat steps d to f to the same color label on the drum unit. Y K A C - Yellow M - Make sure that you match the toner cartridge color to clean each of the toner cartridge and slide the toner cartridge into the...
Users Manual - English - Page 109

... not apply to problems caused by your drum will be significantly less than this estimate. Clean the corona wires in the drum unit. (See Cleaning the corona wires on . j Close the front cover of its life. Under ideal conditions, the average drum life is at approximately 25,000 pages. Replace the drum unit with a non-Brother drum unit may be printed by the use only...
Users Manual - English - Page 131

....  Turn the power switch off distinctive ring on page 40.) Drum Error The corona wire on the drum unit Clean the corona wire on the drum unit. on page 107.) Jam MP Tray The paper is jammed in the ... faxes or Fax Journal report on page 100.)  If the problem continues, call Brother Customer Service. Although the size of paper in the paper tray matches the paper size that...
Users Manual - English - Page 149

...Try receiving from within that country. (MFC-9560CDW) In USA: Please go to the Brother Solutions Center at http://solutions.brother.com/ and click Manuals on page ...manuals. Clean the corona wires on the drum unit. (See Cleaning the corona wires on your machine B IMPORTANT For technical help , the Brother Solutions Center offers the latest FAQs and troubleshooting tips. The corona wires for ...
Users Manual - English - Page 153

...corona wire is dirty. (See Cleaning the scanner glass in Appendix A of the Advanced User's Guide and Cleaning the corona wires...-click Brother MFC-XXXX Printer. Make sure that the toner cartridge and drum unit are ...Devices and Printers. Make sure that Use Printer Offline is unchecked. (Windows® 2000) Click the Start button and choose Settings and then Printers. Right-click Brother MFC...
Users Manual - English - Page 159

...ABCDEFGHIJKLMNOPQRSTUVWXYZ. 0123456789. abcdefghijklmnopqrstuvwxyz.  Clean all four corona wires (one for each color) inside the drum unit by sliding the green tab. (See Cleaning the corona wires on page 68.)  Make sure the corona wire green tabs are at their home positions (a).  Clean the scanner glass and scanner glass strip. (See Cleaning the scanner glass in Appendix...
Users Manual - English - Page 209

... 92 Comm. Automatic fax receive 34 easy receive 36 fax redial 46 B Belt unit replacing 79 Brother accessories and supplies ii Brother numbers i Customer Service i FAQs (frequently asked questions) ..........i product support i service centers i warranties iv, v, vii C Cleaning corona wires 68 Connecting external TAD (answering machine) .......40 external telephone 42 Consumable items...
Users Manual - English - Page 219

... edge flip 51 Advanced Duplex Copy (short edge flip 53 A Routine maintenance 55 Cleaning and checking the machine 55 Cleaning the outside of the machine 55 Cleaning the scanner 56 Cleaning the laser scanner windows 57 Cleaning the corona wires 61 Cleaning the drum unit 65 Cleaning the paper pick-up rollers 71 Calibration ...72 Auto Registration 73 Manual Registration 73...
Users Manual - English - Page 281

A 61 Routine maintenance b Hold the green handle of the drum unit. Pull the drum unit out until it stops. Cleaning the corona wires A If you have print quality problems, clean the four corona wires as follows: a Press the front cover release button and then open the front cover.
Users Manual - English - Page 283

g Repeat steps d to f to left several times. If you do not, printed pages may have a vertical stripe. e Clean the corona wire inside the drum unit by gently sliding the green tab from left to right and right to clean each of three remaining corona wires. 63 Routine maintenance f Close the corona wire cover. 1 A Note Be sure to return the tab to the home position (a) (1).

Similar Questions

Ask a New Question
Use the box below to post a new question about this Brother International product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Brother International Manuals

Find free Brother International MFC-9460CDN manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Brother International Reviews

View thousands of Brother International user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Brother International customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Brother International customer service rankings, employee comments and much more from our sister site.