Question posted by alphadog on September 21st, 2023

Amp Power On

Amp lights up for 2-3 seconds then goes off

Current Answers

Answer #1: Posted by SonuKumar on September 21st, 2023 11:06 PM
SonuKumar

Member since:
May 9th, 2021

Points: 16,617,800
100
points
There are a few possible reasons why your Behringer INUKE NU6000 amp might be lighting up for 2-3 seconds then going off.

Power supply: The most likely cause of this problem is a problem with the amp's power supply. If the power supply is not providing enough power to the amp, the amp will not be able to turn on properly and will shut down after a few seconds.

Overheating: If the amp is overheating, it will also shut down to protect itself. Overheating can be caused by a number of things, such as a blocked fan, a dusty interior, or operating the amp in a hot environment.

Faulty component: If one of the amp's internal components is faulty, it can also cause the amp to shut down. This could be anything from a capacitor to a transistor.

If you are not comfortable troubleshooting the problem yourself, you should take the amp to a qualified technician to have it diagnosed and repaired.

Here are some things you can try to troubleshoot the problem:

Check the power cord and outlet: Make sure that the power cord is securely plugged into the amp and that the outlet is working properly.

Check the fan: Make sure that the fan is not blocked and that it is spinning freely.

Clean the interior of the amp: Use a can of compressed air to blow out any dust and dirt that has accumulated inside the amp.

Operate the amp in a cool environment: If the amp is overheating, try operating it in a cooler environment.

Check the speaker connections: Make sure that the speaker connections are tight and secure.

If you have tried all of the above and the amp is still shutting down, you should take it to a qualified technician to have it diagnosed and repaired.


Please respond to my effort to provide you with the best possible solution by using the "Acceptable Solution" and/or the "Helpful" buttons when the answer has proven to be helpful.

Regards,
Sonu
Your search handyman for all e-support needs!!

Related Behringer iNUKE NU6000 Manual Pages

Brochure - Page 1

...Power button, the Power LED lights to come. The front panel controls and indicators provide your rig effortlessly for many years to show the amp is combined with Signal LEDs that gives the iNUKE... buildup Ultra-efficient switch-mode power supply for action. PA Amplifiers iNUKE NU6000DSP NU3000DSP/NU1000DSP NU6000/NU3000/NU1000 iNUKE NU6000DSP- Our revolutionary high-density...
Brochure - Page 2

... that enable iNUKE amps to fullrange loudspeakers... power gets to ensure...iNUKE NU6000DSP NU3000DSP NU1000DSP NU6000 NU3000 NU1000 Front panel LCD display enables setup and adjustment without shutting down the show "Back-to-front" ventilation system prevents thermal buildup for ultimate reliability Independent DC, LF and thermal overload protection on each channel automatically protects amplifier...
Brochure - Page 3

... NU1000DSP NU6000 NU3000 NU1000 iNUKE NU6000- Ultra-Lightweight, High-Density 6000-Watt Power Amplifier Delivers 2 x 3000 Watts into 4 Ohms, 2 x 1500 Watts into 4 Ohms (bridge mode) and weighs less than 7 lbs / 3.3 kg Common features Ultimate reliability through revolutionary cool-running High-Density Class-D technology with "near-zero" thermal build up Ultra-efficient switch-mode power supply...
Brochure - Page 4

iNUKE NU6000DSP NU3000DSP NU1000DSP NU6000... Independent DC, LF and thermal overload protection on each channel automatically protects amplifier and speakers without shutting down the show "Back-to-front" ventilation system... Page 4 of 11 System configuration is a breeze thanks to iNUKE's Amp Remote software (Available on iNUKE DSP models only) Dynamic EQ combines the effects of equalization and...
Brochure - Page 5

Page 5 of 11 iNUKE NU6000DSP NU3000DSP NU1000DSP NU6000 NU3000 NU1000 iNUKE NU3000 - Live Setup with PA and Floor Monitor UMA25S ULTRACOUSTIC ACX900 XM8500 Vocal Mics Tape In EUROLIVE F1320D Active Floor Monitor Mon out Tape Out Portable Multi-track Recorder XENYX X1222USB L Main out R iNUKE NU3000 B215XL Passive Loudspeakers
Brochure - Page 6

Page 6 of 11 iNUKE NU6000DSP NU3000DSP NU1000DSP NU6000 NU3000 NU1000 Concert Setup with Delay Line VP1520 Right delay line iNUKE NU3000DSP Group 2 Out XENYX XL3200 Group 1 Out Main A Out FOH (Front Of House) loudspeaker system iNUKE NU3000DSP Left delay line VP1520
Brochure - Page 7

Page 7 of 11 iNUKE NU6000DSP NU3000DSP NU1000DSP NU6000 NU3000 NU1000 iNUKE NU1000 - Live Stereo DJ Setup with Passive PA B1800X PRO Passive Subwoofer VP1520 Passive Loudspeaker iNUKE NU1000 HPX2000 Turntables B-CONTROL DEEJAY BCD3000 XM8500 Talkover Mic
Brochure - Page 8

...Amplifier protection Load protection 2 x combo jacks 10 kΩ unbalanced, 20 kΩ balanced 2 x locking-style professional speaker connectors Class D 140 @ 8 Ω >98 dB Front panel USB connector type B for Process, Setup, Up/Down, Exit Indicators Power... 11 iNUKE NU6000DSP NU3000DSP NU1000DSP NU6000 NU3000 NU1000 Specifications NU6000DSP Output Power Maximum output power Stereo...
Brochure - Page 9

Page 9 of 11 iNUKE NU6000DSP NU3000DSP NU1000DSP NU6000 NU3000 NU1000 Connectors Inputs Input impedance Outputs Output circuit type Distortion Frequency response Damping factor Signal-to-noise USB Circuit Protection Cooling Amplifier protection Load protection 2 x combo jacks 10 kΩ unbalanced, 20 kΩ balanced 2 x locking-style professional speaker connectors Class D 145 @ 8 Ω >98 ...
Brochure - Page 10

Page 10 of 11 iNUKE NU6000DSP NU3000DSP NU1000DSP NU6000 NU3000 NU1000 NU6000 Output Power Maximum Output Power Stereo 8 Ω per channel, stereo 4 Ω per channel, ...Output circuit type Distortion Frequency response Damping factor Signal-to-noise Circuit Protection Cooling Amplifier protection Load protection Power switch Gain controls (channels A and B) Mode switch (bridge/stereo/mono)...
Brochure - Page 11

... as such are subject to change without the express written permission of MUSIC Group IP Ltd. All trademarks are the property of the MUSIC Group (music-group.com). Page 11 of 11 iNUKE NU6000DSP NU3000DSP NU1000DSP NU6000 NU3000 NU1000 NU1000 Output Power Maximum Output Power Stereo 8 Ω per channel, stereo 4 Ω per channel, stereo 2 Ω per channel...
Quick Start Guide - Page 1

(Check Out behringer.com for Full Manual) iNUKE NU6000/NU3000/NU1000 Ultra-Lightweight High-Density 6000/3000/1000-Watt Power Amplifier
Quick Start Guide - Page 2

... by MUSIC Group. (4) Warranty claims other apparatus (including amplifiers) that contained in the accompanying literature. In case MUSIC Group decides...iNUKE NU6000/NU3000/NU1000 Important Safety Instructions Terminals marked with this apparatus near any heat sources such as radiators, heat registers, stoves, or other than those indicated above are expressly excluded from a MUSIC...
Quick Start Guide - Page 16

...iNUKE NU6000/NU3000/NU1000 Responsible Party Name: Address: Phone/Fax No.: MUSIC Group Services US Inc. 18912 North Creek Parkway, Suite 200 Bothell, WA 98011, USA Phone: +1 425 672 0816 Fax: +1 425 673 7647 iNUKE NU6000... reception, which the receiver is encouraged to try to correct the interference by MUSIC Group can radiate radio frequency energy and, if not installed and used in ...

Similar Questions

Behringer Inuke Nu6000?
What part is at position D1 of the Behringer iNuke nu6000?
(Posted by thecavepig 1 year ago)
Can't Select Effects.
I turn the knob to select and then push and nothing happens
(Posted by Breavill96 3 years ago)
Power Button Flashes
The power button on the front flashes when I turn on the power main switch on the back. When I power...
(Posted by jdcarguy 6 years ago)
Inuke 3000 Troubleshooting
The yellow light on the left of the controle front pannel plinking and also no out put on this chann...
(Posted by pinsinanan 8 years ago)
How To Reduce The Fan Noise Of Behringer I Nuke 6000 Dsp Amp
sir i want to purchase the behringer i nuke 6000 dsp amp but i am little confused over the fan noise...
(Posted by pwarude54 8 years ago)
Ask a New Question
Use the box below to post a new question about this Behringer product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Behringer Manuals

Find free Behringer iNUKE NU6000 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Behringer Reviews

View thousands of Behringer user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Behringer customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Behringer customer service rankings, employee comments and much more from our sister site.