Popular Whirlpool WVU37UC0F Manual Pages
Use & Care Guide - Page 3
... reproductive harm.
3 All safety messages will tell you don't follow instructions. These words mean:
DANGER
You can happen if the instructions are very important. WARNING
You can kill or hurt you don't ...many important safety messages in this manual and on your appliance.
All safety messages will follow instructions.
RANGE HOOD SAFETY
Your safety and the safety of others .
Use & Care Guide - Page 5
... all parts are factory set for ...instructions provided with local codes. Consult the cooktop/range manufacturer installation instructions before starting installation. Product Dimensions
B AI
C
Centerline
D
H
E
GF
A. 619/54" (16 cm) B. 2" (5 cm) C. 825/64" (21.3 cm) D. 1" (2.54 cm) E. 832/32" (22.8 cm) F. 1911/16" (50 cm) G. 11/2" (3.8 cm) H. 36" (91.4 cm) for 36" (91.4 cm) models...
Use & Care Guide - Page 6
...should be as close as part of outside temperatures as possible to the outside through the roof or wall. Makeup Air
Local building codes may require the use of ... Filter Kit (purchased separately)
E. Recirculating grid
6 Installation Clearances
C
B D
A
E
A. 18" (45.7 cm) min. bottom of range hood to the outdoors, except for 36" (91.4 cm) models D. 12" (30.5 cm) minimum cabinet depth ...
Use & Care Guide - Page 7
....1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all governing codes and ordinances.
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used , it is recommended that a qualified electrician determine that the electrical installation is adequate. A copy...
Use & Care Guide - Page 8
...Replace all local codes and ordinances. Determine and clearly mark a vertical centerline on the model/serial/rating plate. Connect the aluminum wiring to the added section of the cabinet. Aluminum/copper connection must conform with local codes and industry accepted wiring practices.
■■ Wire sizes and connections must conform to aluminum.
INSTALLATION INSTRUCTIONS...
Use & Care Guide - Page 10
... mounting plate or 3¹⁄4" x 10" (8.3 cm x 25.4 cm) vent damper, depending on your vent system installation. NOTE: An optional 7" (17.8 cm) round damper is neccesary to range hood with a TORX® T10 screwdriver and set aside.
B
A C
B
D
A. A
A. See the "Venting Requirements" section.
2.
Horizontal air transition
Only for ordering.
1. Remove top rectangular and...
Use & Care Guide - Page 11
Bend spring clips away from metal grease filter. 7. A
8. A
9. A.
Bend spring clips back into top side of metal filter. Replace metal grease filter.
A. Remove the non-vented (recirculating) vent cover.
Non-vented (recirculating) vent cover
11 Slide the venting lever down as shown in the ...
Use & Care Guide - Page 12
... relief. Using a Phillips screwdriver, push on each mounting tab upward approximately 45°. Attach the screws to the National Electric Code or CSA standards and local codes and ordinances. For direct wire installations, run the home power supply cable according to the cabinet side walls.
8. Power supply knockout
2. A. A
4. IMPORTANT: The brackets should touch...
Use & Care Guide - Page 13
... (B) together. Connect Vent System
Connect the ventwork to the National Electric Code or CSA standards and local codes and ordinances. Power Supply Cable Installation
1. Remove the screw from power supply to do so can result in terminal box.
Replace all parts and panels before servicing. Disconnect power. White wires B. Black wires C. Use UL Listed wire connectors...
Use & Care Guide - Page 14
... optional power cord kit installations, follow the instructions supplied with this model range hood. See the "Accessories" section for information on /off . NOTE: Use only with range hood cord connection kits that have been investigated and found acceptable for OFF. Replace grease filter if removed. Check the operation of the range hood. See the...
Use & Care Guide - Page 15
... Grease Filter
For vented installations:
1. Remove each filter by a service technician only. Replacing an LED Lamp
■■ For stainless steel models, Stainless Steel Cleaner and Polish Part Number 31462A (not included): See the "Assistance or Service" section to avoid scratching or damaging the surface.
2. To avoid damage to the following instructions. See the "Warranty...
Use & Care Guide - Page 16
...BK
Mechanical Push Buttons (4 button 3 Speeds)
LED
LED
BU BK
YL
BK
BU
BK
W H
YL BU 10uF
LED DRIVER
BU
YL B R
GN RD W H
YL/GN W H BK YL/GN
M
N L GND
SEL0120629
OUTPUT:700mA (2-... (L-2)
MED SPEED BLACK / RED (L-3)
HIGH SPEED BLACK / GREY (L-4)
MOTOR SPECIFICATIONS
POWER SUPPLY 120 VAC
FREQUENCY
60 HZ
POWER ABSORTION 180W
BLUE / GREY
31
BLUE / RED
44
BLUE / WHITE
54...
Use & Care Guide - Page 17
... Please include a daytime phone number in Canada.
■■ Features and specifications on our full line of appliances.
■■ Referrals to local dealers, repair parts distributors, and service companies.
Our consultants provide assistance with :
■■ Scheduling of service. For further assistance
Whirlpool Brand Home Appliances Customer eXperience Centre Whirlpool...
Use & Care Guide - Page 18
... where an authorized Whirlpool
applies only when the major appliance
servicer is installed,
installation instructions.
Repairs to parts or systems to use with servicing, removal or replacement of incidental or consequential damages, so these excluded circumstances shall be warranted for appliances with original model/serial numbers removed, altered or not easily determined. warranty...