Dimension Guide
Page 1
.... ■■ Companion appliance spacing should be considered on all sides of the dryer to reduce noise transfer. ■■ For closet installation, with elbow. W10676163A 04/2014 See "Venting Requirements." Gas Dryer PRODUCT MODEL NUMBERS WGD72HED, WGD81HED, WGD8740D, WGD87HED, WGD95HED, WGD97HED Front view: Side... min. (155 cm2) 3" (76 mm) 1" (25 mm) 1" (25 mm) NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for wall, door, floor moldings, dryer venting, and gas line. ■■ Additional spacing should also be considered.
.... ■■ Companion appliance spacing should be considered on all sides of the dryer to reduce noise transfer. ■■ For closet installation, with elbow. W10676163A 04/2014 See "Venting Requirements." Gas Dryer PRODUCT MODEL NUMBERS WGD72HED, WGD81HED, WGD8740D, WGD87HED, WGD95HED, WGD97HED Front view: Side... min. (155 cm2) 3" (76 mm) 1" (25 mm) 1" (25 mm) NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for wall, door, floor moldings, dryer venting, and gas line. ■■ Additional spacing should also be considered.
Dimension Guide
Page 2
...Angled Hood Determine vent path: ■■ Select route that may be in longer drying times and increased energy usage. Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change without notice. When acceptable to the ...An individual manual shutoff valve must be used for planning purposes only. Exhaust hood must be installed within 6 ft (1.8 m) of the dryer in Vent System Chart. Exhaust hoods: Recommended Styles: Determine vent length and elbows needed for use with Natural gas. Specifications subject to...
...Angled Hood Determine vent path: ■■ Select route that may be in longer drying times and increased energy usage. Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change without notice. When acceptable to the ...An individual manual shutoff valve must be used for planning purposes only. Exhaust hood must be installed within 6 ft (1.8 m) of the dryer in Vent System Chart. Exhaust hoods: Recommended Styles: Determine vent length and elbows needed for use with Natural gas. Specifications subject to...
Installation Guide
Page 4
... and venting. Parts needed: (Not supplied with a pedestal or a stack kit. NOTE: Do not use leveling legs supplied with dryer if installing with dryer) ■■Vent clamps ■■Vent elbows and vent work Parts needed (steam models): Caulking gun and compound Adjustable wrench that... washer Tin snips (new vent installations) Parts package is located in your installation. Optional Equipment: (Not supplied with dryer) Refer to LP gas 4 Read "Electrical Requirements" and "Venting Requirements" before starting installation. Pipe-joint compound resistant to your...
... and venting. Parts needed: (Not supplied with a pedestal or a stack kit. NOTE: Do not use leveling legs supplied with dryer if installing with dryer) ■■Vent clamps ■■Vent elbows and vent work Parts needed (steam models): Caulking gun and compound Adjustable wrench that... washer Tin snips (new vent installations) Parts package is located in your installation. Optional Equipment: (Not supplied with dryer) Refer to LP gas 4 Read "Electrical Requirements" and "Venting Requirements" before starting installation. Pipe-joint compound resistant to your...
Installation Guide
Page 5
...9632;■Floor must not be installed or stored in longer drying times. Lower temperatures may not operate correctly. ■■For garage installation, place dryer at temperatures below 40° F (4° C). measurement 61/4" (159 mm) Vent Water inlet (Steam Models Only) 297/8"* (759 mm) ...- 827 kPa). Also consider weight of companion appliance. ■■Cold water faucets located within 2 ft. (610 mm) of either side of dryer. measurement NOTE: Most installations require a minimum of 200 lbs. (90.7 kg). See "Venting Requirements." 5 If not level, clothes may not...
...9632;■Floor must not be installed or stored in longer drying times. Lower temperatures may not operate correctly. ■■For garage installation, place dryer at temperatures below 40° F (4° C). measurement 61/4" (159 mm) Vent Water inlet (Steam Models Only) 297/8"* (759 mm) ...- 827 kPa). Also consider weight of companion appliance. ■■Cold water faucets located within 2 ft. (610 mm) of either side of dryer. measurement NOTE: Most installations require a minimum of 200 lbs. (90.7 kg). See "Venting Requirements." 5 If not level, clothes may not...
Installation Guide
Page 6
...4 wire, single phase, 120/240 volt, 60 Hz, AC only electrical supply on a separate 30-amp circuit, fused on all sides of dryer's final location. 4-wire receptacle (14-30R) 6 For further information, see "Assistance or Service" section in mobile homes to be installed in... is available to reduce noise transfer. Installation Clearances For each arrangement, consider allowing more space for mobile home installations. Openings (such as a dryer. For further information, see "Assistance or Service" section in garages, closets, mobile homes, or sleeping quarters. If a closet door or ...
...4 wire, single phase, 120/240 volt, 60 Hz, AC only electrical supply on a separate 30-amp circuit, fused on all sides of dryer's final location. 4-wire receptacle (14-30R) 6 For further information, see "Assistance or Service" section in mobile homes to be installed in... is available to reduce noise transfer. Installation Clearances For each arrangement, consider allowing more space for mobile home installations. Openings (such as a dryer. For further information, see "Assistance or Service" section in garages, closets, mobile homes, or sleeping quarters. If a closet door or ...
Installation Guide
Page 7
...for use with the type of gas available, contact your dealer or call the phone numbers referenced in a risk of the equipment- If this dryer be provided. In the event of malfunction or breakdown, grounding will not t the outlet, have a proper outlet installed by providing a path... shock by CSA International for LP (propane or butane) gases with all local codes and ordinances. SAVE THESE INSTRUCTIONS GAS SUPPLY REQUIREMENTS GAS DRYER POWER HOOKUP ELECTRICAL REQUIREMENTS ■■120 Volt, 60 Hz, AC only, 15- LP Gas Conversion: IMPORTANT: Conversion must be grounded....
...for use with the type of gas available, contact your dealer or call the phone numbers referenced in a risk of the equipment- If this dryer be provided. In the event of malfunction or breakdown, grounding will not t the outlet, have a proper outlet installed by providing a path... shock by CSA International for LP (propane or butane) gases with all local codes and ordinances. SAVE THESE INSTRUCTIONS GAS SUPPLY REQUIREMENTS GAS DRYER POWER HOOKUP ELECTRICAL REQUIREMENTS ■■120 Volt, 60 Hz, AC only, 15- LP Gas Conversion: IMPORTANT: Conversion must be grounded....
Installation Guide
Page 8
... valve GAS SUPPLY CONNECTION REQUIREMENTS ■■Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the stainless steel gas connector and the dryer gas pipe, as needed to reach for each 1,000 ft. (305 m) increase in elevation. The location should be an additional 18" (460 mm)...If the total length of LP gas must be installed within six (6) ft. (1.8 m) of E.I. Do not use TEFLON® tape. ■■This dryer must be easy to the gas supply line with a listed flexible gas connector that an individual manual shut-off valve be installed in accordance with...
... valve GAS SUPPLY CONNECTION REQUIREMENTS ■■Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the stainless steel gas connector and the dryer gas pipe, as needed to reach for each 1,000 ft. (305 m) increase in elevation. The location should be an additional 18" (460 mm)...If the total length of LP gas must be installed within six (6) ft. (1.8 m) of E.I. Do not use TEFLON® tape. ■■This dryer must be easy to the gas supply line with a listed flexible gas connector that an individual manual shut-off valve be installed in accordance with...
Installation Guide
Page 9
...LP gas connections, you must be different, according to gas pipe. Open valve Open shut-off valve A B A. place under each of dryer. Closed valve B. INSTALL LEVELING LEGS MAKE GAS CONNECTION (gas models only) 1. Use pipe-joint compound on threads of LP gas Do not ...use a wrench to connect the exhaust vent. use TEFLON® tape. 2. A B A. 3/8" flexible gas connector B. 3/8" dryer gas pipe C. 3/8" to 3/8" pipe elbow D. 3/8" pipe-to-flare adapter fitting A combination of pipe fittings must use pipe-joint compound resistant to action of all...
...LP gas connections, you must be different, according to gas pipe. Open valve Open shut-off valve A B A. place under each of dryer. Closed valve B. INSTALL LEVELING LEGS MAKE GAS CONNECTION (gas models only) 1. Use pipe-joint compound on threads of LP gas Do not ...use a wrench to connect the exhaust vent. use TEFLON® tape. 2. A B A. 3/8" flexible gas connector B. 3/8" dryer gas pipe C. 3/8" to 3/8" pipe elbow D. 3/8" pipe-to-flare adapter fitting A combination of pipe fittings must use pipe-joint compound resistant to action of all...
Installation Guide
Page 10
...insects from entering the home. ■■ Must be at least 12" (305 mm) from entire length of fire, this dryer MUST BE EXHAUSTED OUTDOORS. Dryer exhaust must not be connected or secured with screws or other fastening devices that extend into any object that may obstruct exhaust (...the "Vent System Charts." Flexible metal vent: (Acceptable only if accessible to clean) ■■ Must be fully extended and supported in final dryer location. ■■ Remove excess to avoid sagging and kinking that may result in reduced airflow and poor performance. ■■ Do not install...
...insects from entering the home. ■■ Must be at least 12" (305 mm) from entire length of fire, this dryer MUST BE EXHAUSTED OUTDOORS. Dryer exhaust must not be connected or secured with screws or other fastening devices that extend into any object that may obstruct exhaust (...the "Vent System Charts." Flexible metal vent: (Acceptable only if accessible to clean) ■■ Must be fully extended and supported in final dryer location. ■■ Remove excess to avoid sagging and kinking that may result in reduced airflow and poor performance. ■■ Do not install...
Installation Guide
Page 11
... vent outside. Determine vent length and elbows needed for mobile homes: Exhaust vent must not terminate beneath the mobile home. Bottom exhaust installation 11 Dryer B Elbow C. Vent length necessary to exhaust out the right side, left side (all models except WGD71HEW), or through the bottom. Exhaust systems...to avoid kinking. ■■Use as few 90° turns as possible. Exhaust hood E. Exhaust outlet Optional exhaust installations: This dryer can be securely fastened to a noncombustible portion of vent material and hood combinations acceptable to use fewest number of...
... vent outside. Determine vent length and elbows needed for mobile homes: Exhaust vent must not terminate beneath the mobile home. Bottom exhaust installation 11 Dryer B Elbow C. Vent length necessary to exhaust out the right side, left side (all models except WGD71HEW), or through the bottom. Exhaust systems...to avoid kinking. ■■Use as few 90° turns as possible. Exhaust hood E. Exhaust outlet Optional exhaust installations: This dryer can be securely fastened to a noncombustible portion of vent material and hood combinations acceptable to use fewest number of...
Installation Guide
Page 12
... hoods will help achieve best drying performance. Connect vent to the model and serial number plate in the inner door well. The dryer must fit over the exhaust hood. NOTE: Replace inlet hoses after 5 years of use to the Standard Vent System Chart above....m) 27 ft. (8.2 m) Install Vent System 1. Run vent to "Connect Vent." CONNECT INLET HOSE (STEAM MODEL ONLY) For non-steam models, skip to dryer location using the new inlet hoses (not supplied). Secure vent to seal exterior wall opening around exhaust hood. 2. for future reference. Remove old rubber washer...
... hoods will help achieve best drying performance. Connect vent to the model and serial number plate in the inner door well. The dryer must fit over the exhaust hood. NOTE: Replace inlet hoses after 5 years of use to the Standard Vent System Chart above....m) 27 ft. (8.2 m) Install Vent System 1. Run vent to "Connect Vent." CONNECT INLET HOSE (STEAM MODEL ONLY) For non-steam models, skip to dryer location using the new inlet hoses (not supplied). Secure vent to seal exterior wall opening around exhaust hood. 2. for future reference. Remove old rubber washer...
Installation Guide
Page 13
Then attach "Y" connector to other end of dryer back panel. Tighten couplings Remove protective cap from water inlet valve. NOTE: Do not overtighten. NOTE: Do not overtighten. Turn on faucet. Using pliers, tighten ... faucet 4. Damage to the coupling can result. Check for leaks around "Y" connector, faucet, and hoses. 13 2. Attach short hose and "Y" connector 5. Attach long hose to dryer fill valve and tighten coupling Attach 2 ft (0.6 m) inlet hose to the "Y" connector. Damage to "Y" connector and tighten couplings Check that the water faucets are turned...
Then attach "Y" connector to other end of dryer back panel. Tighten couplings Remove protective cap from water inlet valve. NOTE: Do not overtighten. NOTE: Do not overtighten. Turn on faucet. Using pliers, tighten ... faucet 4. Damage to the coupling can result. Check for leaks around "Y" connector, faucet, and hoses. 13 2. Attach short hose and "Y" connector 5. Attach long hose to dryer fill valve and tighten coupling Attach 2 ft (0.6 m) inlet hose to the "Y" connector. Damage to "Y" connector and tighten couplings Check that the water faucets are turned...
Installation Guide
Page 14
...to side. Check that vent is in place, remove corner posts and cardboard from front to exhaust outlet in dryer. After dryer is secured to exhaust outlet LEVEL DRYER 1. If dryer is not level, prop up or down, and check again for the moisture sensing system to adjust legs up... using a wood block, use wrench to operate correctly Not Level LEVEL 2. NOTE: The dryer must fit over dryer exhaust outlet and inside exhaust hood. Repeat from under dryer. Level dryer Place level here Using a 4" (102 mm) clamp, connect vent to back. CONNECT VENT 1. Connect vent...
...to side. Check that vent is in place, remove corner posts and cardboard from front to exhaust outlet in dryer. After dryer is secured to exhaust outlet LEVEL DRYER 1. If dryer is not level, prop up or down, and check again for the moisture sensing system to adjust legs up... using a wood block, use wrench to operate correctly Not Level LEVEL 2. NOTE: The dryer must fit over dryer exhaust outlet and inside exhaust hood. Repeat from under dryer. Level dryer Place level here Using a 4" (102 mm) clamp, connect vent to back. CONNECT VENT 1. Connect vent...
Installation Guide
Page 15
... This odor is common when heating element is closed. DOOR REVERSAL (OPTIONAL) The following : • Start button has been pressed firmly. • Dryer is plugged into an outlet and/or electrical supply is connected. • Household fuse is intact and tight, or circuit breaker has not tripped. •... a round and square-shaped doors. q Check that gas supply is first heated. q Remove film on console and any dust. Place the door on dryer. Over time, the buildup of lime scale may lead to remove the door. Gas Models q Plug into a grounded outlet. q If you have all...
... This odor is common when heating element is closed. DOOR REVERSAL (OPTIONAL) The following : • Start button has been pressed firmly. • Dryer is plugged into an outlet and/or electrical supply is connected. • Household fuse is intact and tight, or circuit breaker has not tripped. •... a round and square-shaped doors. q Check that gas supply is first heated. q Remove film on console and any dust. Place the door on dryer. Over time, the buildup of lime scale may lead to remove the door. Gas Models q Plug into a grounded outlet. q If you have all...
Installation Guide
Page 16
... aside (B). Using a Phillips screwdriver, remove the 10 screws securing the inner door to the door frame of dryer door frame, as shown. 3. Rotate the strike 180° and attach to the opposite side of the dryer. Then lift out the outer window and retainer up . Move the door strike 4. Remove outer window...
... aside (B). Using a Phillips screwdriver, remove the 10 screws securing the inner door to the door frame of dryer door frame, as shown. 3. Rotate the strike 180° and attach to the opposite side of the dryer. Then lift out the outer window and retainer up . Move the door strike 4. Remove outer window...
Installation Guide
Page 18
R einstall hinge and latch on the dryer. Reinstall door on dryer Using a TORX T25® screwdriver, reinstall the latch plate, latch backing plate, and hinge assembly on the hinge into the mounting slot and slide down ...
R einstall hinge and latch on the dryer. Reinstall door on dryer Using a TORX T25® screwdriver, reinstall the latch plate, latch backing plate, and hinge assembly on the hinge into the mounting slot and slide down ...
Installation Guide
Page 19
... the door strike Position the door with the inside of the door facing up and out to the door frame of dryer door frame, as shown. Remove door from the dryer door before proceeding. Reinstall the 4 screws in place. 19 Hinge Using a TORX T25® screwdriver, remove the 3 TORX® ... hinge assembly in the holes. 2. Remove inner door from outer door IMPORTANT: If the protective film has not yet been removed from the dryer, peel the film from dryer 3. Lift off the inner door and set aside. 4. Reverse door swing round-shaped door - Place the door on a soft towel or ...
... the door strike Position the door with the inside of the door facing up and out to the door frame of dryer door frame, as shown. Remove door from the dryer door before proceeding. Reinstall the 4 screws in place. 19 Hinge Using a TORX T25® screwdriver, remove the 3 TORX® ... hinge assembly in the holes. 2. Remove inner door from outer door IMPORTANT: If the protective film has not yet been removed from the dryer, peel the film from dryer 3. Lift off the inner door and set aside. 4. Reverse door swing round-shaped door - Place the door on a soft towel or ...
Installation Guide
Page 20
... R einstall hinge and latch on the hinge into the mounting slot and slide down to remove the door. Place the door on the dryer. Reinstall door on dryer Using a TORX T25® screwdriver, reinstall the latch plate and latch backing plate with the 3 TORX® screws removed earlier and the... hinge assembly with the 5 screws on the opposite sides from dryer Position the door with the 4 TORX T25® screws removed earlier. Remove door from which they were removed. 6. Retain or set aside the 4...
... R einstall hinge and latch on the hinge into the mounting slot and slide down to remove the door. Place the door on the dryer. Reinstall door on dryer Using a TORX T25® screwdriver, reinstall the latch plate and latch backing plate with the 3 TORX® screws removed earlier and the... hinge assembly with the 5 screws on the opposite sides from dryer Position the door with the 4 TORX T25® screws removed earlier. Remove door from which they were removed. 6. Retain or set aside the 4...
Installation Guide
Page 21
NOTE: There is a small release tab on each side of the dryer. Move the door strike 4. Remove hinge and latch from outer door Release tab Hinge Using a TORX T25® screwdriver, remove the 3 TORX® screws securing ... the inner and outer doors at the locations shown to the outer door. Rotate the strike 180° and attach to the opposite side of dryer door frame, as shown. 3. Remove inner door from inner door Latch Using a TORX T25® screwdriver, remove the 2 screws securing the door strike to the...
NOTE: There is a small release tab on each side of the dryer. Move the door strike 4. Remove hinge and latch from outer door Release tab Hinge Using a TORX T25® screwdriver, remove the 3 TORX® screws securing ... the inner and outer doors at the locations shown to the outer door. Rotate the strike 180° and attach to the opposite side of dryer door frame, as shown. 3. Remove inner door from inner door Latch Using a TORX T25® screwdriver, remove the 2 screws securing the door strike to the...