Dimension Guide
Page 1
...1" (25 mm) 1" (25 mm) Additional spacing should be considered. Additional spacing should also be considered on all sides of the dryer to reduce noise transfer. Installation spacing for exhaust vent with equivalent ventilation openings are required. Companion appliance spacing should be considered for ease ... 3" (76 mm) 48 in.2 min. (310 cm2) 24 in the top and bottom of 5" (127 mm) clearance behind dryer for recessed area or closet installation All dimensions show recommended and minimum spacing allowed. See "Venting Requirements." Louvered doors with elbow. W10775221A ...
...1" (25 mm) 1" (25 mm) Additional spacing should be considered. Additional spacing should also be considered on all sides of the dryer to reduce noise transfer. Installation spacing for exhaust vent with equivalent ventilation openings are required. Companion appliance spacing should be considered for ease ... 3" (76 mm) 48 in.2 min. (310 cm2) 24 in the top and bottom of 5" (127 mm) clearance behind dryer for recessed area or closet installation All dimensions show recommended and minimum spacing allowed. See "Venting Requirements." Louvered doors with elbow. W10775221A ...
Dimension Guide
Page 2
...Style: Box Hood Angled Hood Determine vent path: ■■ Select route that may be installed within 6 ft (1.8 m) of the dryer in the path of elbows and turns. ■■ When using new inlet hoses. For complete details, see Installation Instructions packed with .... Do not overtighten. INSTALLATION REQUIREMENTS GAS SUPPLY REQUIREMENTS Gas supply: This dryer is equipped for use vent runs longer than those specified in longer drying times and increased energy usage. Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve ...
...Style: Box Hood Angled Hood Determine vent path: ■■ Select route that may be installed within 6 ft (1.8 m) of the dryer in the path of elbows and turns. ■■ When using new inlet hoses. For complete details, see Installation Instructions packed with .... Do not overtighten. INSTALLATION REQUIREMENTS GAS SUPPLY REQUIREMENTS Gas supply: This dryer is equipped for use vent runs longer than those specified in longer drying times and increased energy usage. Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve ...
Installation Guide
Page 4
... nut driver (recommended) Level Pipe-joint compound resistant to 1" (25 mm) or hex-head socket wrench Rubber washer Parts package is located in dryer drum. Check that all models): Tape measure Pliers Utility knife Tin snips (new vent installations) Leveling legs (4) Parts supplied (steam models): "Y" ... Adjustable wrench that opens to LP gas Parts supplied (all parts are included. NOTE: Do not use leveling legs supplied with dryer if installing with dryer) ■■Vent clamps ■■Vent elbows and vent work 4 Tools needed for all installations: Tools needed : ...
... nut driver (recommended) Level Pipe-joint compound resistant to 1" (25 mm) or hex-head socket wrench Rubber washer Parts package is located in dryer drum. Check that all models): Tape measure Pliers Utility knife Tin snips (new vent installations) Leveling legs (4) Parts supplied (steam models): "Y" ... Adjustable wrench that opens to LP gas Parts supplied (all parts are included. NOTE: Do not use leveling legs supplied with dryer if installing with dryer) ■■Vent clamps ■■Vent elbows and vent work 4 Tools needed for all installations: Tools needed : ...
Installation Guide
Page 5
.... See "Venting Requirements." 5 Also consider weight of companion appliance. ■■Cold water faucets located within 2 ft. (610 mm) of either side of dryer. You may be exposed to shut off at least 18" (460 mm) above floor. measurement NOTE: Most installations require a minimum of 5" (127 mm) ...for your washer using the supplied "Y" connector and a short hose (which you will need 18" (460 mm) to bottom of dryer. ■■The dryer must support dryer weight of 20-120 psi (138-827 kPa). Check local codes. See "Venting Requirements." ■■A separate 15 or 20 amp...
.... See "Venting Requirements." 5 Also consider weight of companion appliance. ■■Cold water faucets located within 2 ft. (610 mm) of either side of dryer. You may be exposed to shut off at least 18" (460 mm) above floor. measurement NOTE: Most installations require a minimum of 5" (127 mm) ...for your washer using the supplied "Y" connector and a short hose (which you will need 18" (460 mm) to bottom of dryer. ■■The dryer must support dryer weight of 20-120 psi (138-827 kPa). Check local codes. See "Venting Requirements." ■■A separate 15 or 20 amp...
Installation Guide
Page 6
... to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for straight back venting only. Minimum installation clearances (dryer only): Recessed Closet Front NA NA Sides Rear Top 0" (0 mm) 0" (0 mm)** 0" (0 mm) 0" (0 mm) 0" (0 mm)** 0" (0 mm) ... air openings in conformance with a CSA International Certified Power Cord intended to an individual branch circuit. ■■This dryer is adequate and in door are acceptable. ■■Companion appliance spacing should be installed in garages, closets, mobile homes...
... to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for straight back venting only. Minimum installation clearances (dryer only): Recessed Closet Front NA NA Sides Rear Top 0" (0 mm) 0" (0 mm)** 0" (0 mm) 0" (0 mm) 0" (0 mm)** 0" (0 mm) ... air openings in conformance with a CSA International Certified Power Cord intended to an individual branch circuit. ■■This dryer is adequate and in door are acceptable. ■■Companion appliance spacing should be installed in garages, closets, mobile homes...
Installation Guide
Page 7
... plug provided with all local codes and ordinances. or 20- The plug must be provided. grounding conductor can result in accordance with the dryer: if it will not t the outlet, have a proper outlet installed by a quali ed electrician. Do not modify the plug provided with the...of gas in doubt as to convert the appliance from the gas specified on the rating plate in the "Assistance or Service" section of your dryer. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of electric shock. grounding conductor ...
... plug provided with all local codes and ordinances. or 20- The plug must be provided. grounding conductor can result in accordance with the dryer: if it will not t the outlet, have a proper outlet installed by a quali ed electrician. Do not modify the plug provided with the...of gas in doubt as to convert the appliance from the gas specified on the rating plate in the "Assistance or Service" section of your dryer. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of electric shock. grounding conductor ...
Installation Guide
Page 8
...disconnected from the gas supply piping system during pressure testing at pressures greater than 20 ft. (6.1 m), use TEFLON® tape. ■■This dryer must be used . Dupont De Nemours and Company. 8 BURNER INPUT REQUIREMENTS Elevations above 2,000 ft. (610 m): ■■When installed above...Do not use a new flexible stainless steel gas connector (Design Certified by the American Gas Association or CSA International) to connect your dryer has a 3⁄8" male pipe thread. GAS SUPPLY LINE Option 1 (Recommended Method) Flexible stainless steel gas connector: ■■...
...disconnected from the gas supply piping system during pressure testing at pressures greater than 20 ft. (6.1 m), use TEFLON® tape. ■■This dryer must be used . Dupont De Nemours and Company. 8 BURNER INPUT REQUIREMENTS Elevations above 2,000 ft. (610 m): ■■When installed above...Do not use a new flexible stainless steel gas connector (Design Certified by the American Gas Association or CSA International) to connect your dryer has a 3⁄8" male pipe thread. GAS SUPPLY LINE Option 1 (Recommended Method) Flexible stainless steel gas connector: ■■...
Installation Guide
Page 9
... legs B A A. Then, test all non-flared male fittings. Bubbles will show a leak. Non-flared male fitting Remove red cap from dryer packaging under entire back edge of pipe fittings must use a wrench to its final location. If flexible metal tubing is no kinks. NOTE:...detection solution. Plan pipe fitting connection (option 1) D C Ddiiaammoonndd mmaarrkkiinngg Examine leveling legs and locate the diamond marking. Stand the dryer up. Slide the dryer on cardboard. 2. A recommended connection is close to finish turning legs until it is shown. valve is open when handle is parallel...
... legs B A A. Then, test all non-flared male fittings. Bubbles will show a leak. Non-flared male fitting Remove red cap from dryer packaging under entire back edge of pipe fittings must use a wrench to its final location. If flexible metal tubing is no kinks. NOTE:...detection solution. Plan pipe fitting connection (option 1) D C Ddiiaammoonndd mmaarrkkiinngg Examine leveling legs and locate the diamond marking. Stand the dryer up. Slide the dryer on cardboard. 2. A recommended connection is close to finish turning legs until it is shown. valve is open when handle is parallel...
Installation Guide
Page 10
... space of a building. Flexible metal vent: (Acceptable only if accessible to clean) ■■ Must be fully extended and supported in final dryer location. ■■ Remove excess to seal all governing codes and ordinances. Replace plastic or metal foil vents with lint. IMPORTANT: Observe all... with rigid metal or flexible metal vents. Recommended Styles: Louvered Hood Acceptable Style: Box Hood WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS. Good Better 4" (102 mm) heavy metal exhaust vent ■■ Only a 4" (102 mm) heavy metal...
... space of a building. Flexible metal vent: (Acceptable only if accessible to clean) ■■ Must be fully extended and supported in final dryer location. ■■ Remove excess to seal all governing codes and ordinances. Replace plastic or metal foil vents with lint. IMPORTANT: Observe all... with rigid metal or flexible metal vents. Recommended Styles: Louvered Hood Acceptable Style: Box Hood WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS. Good Better 4" (102 mm) heavy metal exhaust vent ■■ Only a 4" (102 mm) heavy metal...
Installation Guide
Page 11
...), or through the bottom. A B C A. or right-side exhaust installation C. Terminate exhaust vent outside. Optional exhaust installations: This dryer can be securely fastened to a noncombustible portion of elbows and turns. ■■When using elbows or making turns, allow as much...Special provisions for best drying performance: ■■Use the "Vent System Charts" on the next page to determine type of dryer. ■■Reduce performance, resulting in "Vent System Charts." Wall D. Exhaust hood E. Left- Plan Vent System Choose your local dealer...
...), or through the bottom. A B C A. or right-side exhaust installation C. Terminate exhaust vent outside. Optional exhaust installations: This dryer can be securely fastened to a noncombustible portion of elbows and turns. ■■When using elbows or making turns, allow as much...Special provisions for best drying performance: ■■Use the "Vent System Charts" on the next page to determine type of dryer. ■■Reduce performance, resulting in "Vent System Charts." Wall D. Exhaust hood E. Left- Plan Vent System Choose your local dealer...
Installation Guide
Page 12
...best drying performance. Install exhaust hood 12" min. (305 mm) 2. Run vent to the type code located on the hoses for future reference. The dryer must fit over the exhaust hood. Record hose installation or replacement dates on the serial number plate in the inner door well. The "Vent System... ft. (42.7 m) 3 Rigid metal 130 ft. (39.6 m) 4 Rigid metal 120 ft. (36.6 m) To determine if your model has a long vent system, refer to dryer location using the new inlet hoses (not supplied). ELE - Do not use to exhaust hood Vent must be DALV - Turn cold water faucet off , remove...
...best drying performance. Install exhaust hood 12" min. (305 mm) 2. Run vent to the type code located on the hoses for future reference. The dryer must fit over the exhaust hood. Record hose installation or replacement dates on the serial number plate in the inner door well. The "Vent System... ft. (42.7 m) 3 Rigid metal 130 ft. (39.6 m) 4 Rigid metal 120 ft. (36.6 m) To determine if your model has a long vent system, refer to dryer location using the new inlet hoses (not supplied). ELE - Do not use to exhaust hood Vent must be DALV - Turn cold water faucet off , remove...
Installation Guide
Page 13
..., tighten the couplings an additional two-thirds turn . Then attach "Y" connector to fill valve at bottom of "Y" connector. Attach other side of dryer back panel. Check for leaks Attach one of the 2 ft (0.6 m) inlet hose. Screw on coupling by hand until it is seated on ... hand until it is seated on fill valve connector. NOTE: Do not overtighten. 2. Attach short hose and "Y" connector 5. Attach long hose to dryer fill valve and tighten coupling Attach 2 ft (0.6 m) inlet hose to the coupling can result. 6. Check for leaks around "Y" connector, faucet, and hoses...
..., tighten the couplings an additional two-thirds turn . Then attach "Y" connector to fill valve at bottom of "Y" connector. Attach other side of dryer back panel. Check for leaks Attach one of the 2 ft (0.6 m) inlet hose. Screw on coupling by hand until it is seated on ... hand until it is seated on fill valve connector. NOTE: Do not overtighten. 2. Attach short hose and "Y" connector 5. Attach long hose to dryer fill valve and tighten coupling Attach 2 ft (0.6 m) inlet hose to the coupling can result. 6. Check for leaks around "Y" connector, faucet, and hoses...
Installation Guide
Page 14
... existing vent, make sure all four legs are snug against the floor and the dryer does not rock. 14 NOTE: The dryer must fit over dryer exhaust outlet and inside exhaust hood. After dryer is clean. Level dryer Place level here Using a 4" (102 mm) clamp, connect vent to crush or kink... vent or flexible gas line. Once dryer is level, make sure vent is in dryer. Dryer vent must be level...
... existing vent, make sure all four legs are snug against the floor and the dryer does not rock. 14 NOTE: The dryer must fit over dryer exhaust outlet and inside exhaust hood. After dryer is clean. Level dryer Place level here Using a 4" (102 mm) clamp, connect vent to crush or kink... vent or flexible gas line. Once dryer is level, make sure vent is in dryer. Dryer vent must be level...
Installation Guide
Page 15
... needed: Min. 8" long TORX T25® †† screwdriver #2 Phillips screwdriver Reverse door swing round-shaped door flat glass - q Check dryer's final location. q If you have all of scale through steps to the need for leaks around "Y" connector, faucet, and hoses. DOOR REVERSAL ...(OPTIONAL) The following : • Start button has been pressed firmly. • Dryer is plugged into an outlet and/or electrical supply is connected. • Household fuse is intact and tight, or circuit breaker has not ...
... needed: Min. 8" long TORX T25® †† screwdriver #2 Phillips screwdriver Reverse door swing round-shaped door flat glass - q Check dryer's final location. q If you have all of scale through steps to the need for leaks around "Y" connector, faucet, and hoses. DOOR REVERSAL ...(OPTIONAL) The following : • Start button has been pressed firmly. • Dryer is plugged into an outlet and/or electrical supply is connected. • Household fuse is intact and tight, or circuit breaker has not ...
Installation Guide
Page 16
...Then lift out the outer window and retainer up . Using a Phillips screwdriver, remove the 10 screws securing the inner door to the opposite side of dryer door frame as shown. 3. Lift off the trim ring and set aside. 16 Rotate the strike 180° and attach to the outer door. 2. Position... rotate the outer window assembly clockwise until the square notches line up with the 4 tabs on the trim ring indicated with the inside of the dryer. Remove inner door from trim ring Using a T25® screwdriver, remove the 2 screws securing the door strike to the door frame of the door...
...Then lift out the outer window and retainer up . Using a Phillips screwdriver, remove the 10 screws securing the inner door to the opposite side of dryer door frame as shown. 3. Lift off the trim ring and set aside. 16 Rotate the strike 180° and attach to the outer door. 2. Position... rotate the outer window assembly clockwise until the square notches line up with the 4 tabs on the trim ring indicated with the inside of the dryer. Remove inner door from trim ring Using a T25® screwdriver, remove the 2 screws securing the door strike to the door frame of the door...
Installation Guide
Page 18
...hinge and latch Latch 9. Reinstall the 10 screws securing the inner door to engage the top tab. Secure in place. 8. Reinstall door on dryer Using a T25® screwdriver, reinstall the latch plate, latch backing plate, and hinge assembly on the hinge into the mounting slot and ... Bottom of the door facing up. 7. Insert the tabs on the opposite sides from which they were removed. R einstall hinge and latch on the dryer. Using a T25® screwdriver, remove the 4 screws on opposite sides Position the door with the inside of door Hinge Using a T25® screwdriver...
...hinge and latch Latch 9. Reinstall the 10 screws securing the inner door to engage the top tab. Secure in place. 8. Reinstall door on dryer Using a T25® screwdriver, reinstall the latch plate, latch backing plate, and hinge assembly on the hinge into the mounting slot and ... Bottom of the door facing up. 7. Insert the tabs on the opposite sides from which they were removed. R einstall hinge and latch on the dryer. Using a T25® screwdriver, remove the 4 screws on opposite sides Position the door with the inside of door Hinge Using a T25® screwdriver...
Installation Guide
Page 19
... door and set aside. 4. Remove hinge and latch Latch Using a T25® screwdriver, remove the 2 screws securing the door strike to the opposite side of dryer door frame, as shown. Reinstall the 4 screws in place. 19 Place the door on a soft towel or other non-scratch surface. Rotate the strike 180... up and out to the outer door. Remove inner door from outer door IMPORTANT: If the protective film has not yet been removed from the dryer, peel the film from dryer 3. Reverse door swing round-shaped door flat glass - double handle 1. Remove door from the...
... door and set aside. 4. Remove hinge and latch Latch Using a T25® screwdriver, remove the 2 screws securing the door strike to the opposite side of dryer door frame, as shown. Reinstall the 4 screws in place. 19 Place the door on a soft towel or other non-scratch surface. Rotate the strike 180... up and out to the outer door. Remove inner door from outer door IMPORTANT: If the protective film has not yet been removed from the dryer, peel the film from dryer 3. Reverse door swing round-shaped door flat glass - double handle 1. Remove door from the...
Installation Guide
Page 20
...; screwdriver, reinstall the latch plate and latch backing plate with the 3 TORX® screws removed earlier and the hinge assembly with the 5 screws on the dryer. Reinstall inner door assembly Bottom of the door facing up. Insert the tabs on opposite sides 7. Secure in place with the inside of door Using...
...; screwdriver, reinstall the latch plate and latch backing plate with the 3 TORX® screws removed earlier and the hinge assembly with the 5 screws on the dryer. Reinstall inner door assembly Bottom of the door facing up. Insert the tabs on opposite sides 7. Secure in place with the inside of door Using...
Installation Guide
Page 21
...inner door and set aside. 4. Remove inner door from outer door IMPORTANT: If the protective film has not yet been removed from the dryer, peel the film from dryer 3. Hinge Using a T25® screwdriver, remove the 3 screws securing the latch plate and latch backing plate and the 5 screws ...hinge and latch Latch Using a T25® screwdriver, remove the 2 screws securing the door strike to the opposite side of the dryer. Remove door from the dryer door before proceeding. Reinstall the 4 screws in place. 21 Move the door strike Position the door with the inside of the door...
...inner door and set aside. 4. Remove inner door from outer door IMPORTANT: If the protective film has not yet been removed from the dryer, peel the film from dryer 3. Hinge Using a T25® screwdriver, remove the 3 screws securing the latch plate and latch backing plate and the 5 screws ...hinge and latch Latch Using a T25® screwdriver, remove the 2 screws securing the door strike to the opposite side of the dryer. Remove door from the dryer door before proceeding. Reinstall the 4 screws in place. 21 Move the door strike Position the door with the inside of the door...