Installation Instructions
Page 1
...Whirlpool.com Table of Contents DRYER SAFETY 2 Installation Requirements 3 Tools and Parts 3 Location Requirements 4 Electrical Requirements 4 INSTALL LEVELING LEGS 6 ELECTRICAL INSTALLATION 7 Power Supply Cord Connection 8 Direct Wire Connection 10 VENTING 13 Venting Requirements 13 Plan Vent System 14 Venting Kits 14 Install Vent... System 15 Connect Inlet Hose 16 Connect Vent 17 Level Dryer 17 Complete Installation Checklist 18 Door...
...Whirlpool.com Table of Contents DRYER SAFETY 2 Installation Requirements 3 Tools and Parts 3 Location Requirements 4 Electrical Requirements 4 INSTALL LEVELING LEGS 6 ELECTRICAL INSTALLATION 7 Power Supply Cord Connection 8 Direct Wire Connection 10 VENTING 13 Venting Requirements 13 Plan Vent System 14 Venting Kits 14 Install Vent... System 15 Connect Inlet Hose 16 Connect Vent 17 Level Dryer 17 Complete Installation Checklist 18 Door...
Installation Instructions
Page 3
...with clothes dryers. NOTE: Do not use with a pedestal or a stack kit. Utility knife Tape measure Leveling legs (4) "Y" connector Level Pliers Caulking gun and compound (for installing new exhaust vent) Min. 8" long Torx® T25 screwdriver (for your installation. INSTALLATION ...REQUIREMENTS TOOLS AND PARTS Gather the required tools and parts before purchasing parts. The kit should be type SRD or SRDT and be required...
...with clothes dryers. NOTE: Do not use with a pedestal or a stack kit. Utility knife Tape measure Leveling legs (4) "Y" connector Level Pliers Caulking gun and compound (for installing new exhaust vent) Min. 8" long Torx® T25 screwdriver (for your installation. INSTALLATION ...REQUIREMENTS TOOLS AND PARTS Gather the required tools and parts before purchasing parts. The kit should be type SRD or SRDT and be required...
Installation Instructions
Page 4
..., place dryer at end of dryer. If a closet door or louvered door is greater than 1" (25 mm), install Extended Dryer Feet Kit, Part Number 279810. measurement. 143/8" (365 mm) If not level, clothes may not tumble properly and automatic sensor cycles may cause dryer...: Most installations require a minimum of 200 lbs. (90.7 kg). Left or right side exhaust 3/4"* (18 mm) 61/2" (165 mm) Power supply cord/cable Vent Water inlet 297/8"* (759 mm) 31/2"* (89 mm) 3/4"* (18 mm) 61/8"* (156 mm) 4 * Approx. LOCATION REQUIREMENTS Check code requirements. Add spacing...
..., place dryer at end of dryer. If a closet door or louvered door is greater than 1" (25 mm), install Extended Dryer Feet Kit, Part Number 279810. measurement. 143/8" (365 mm) If not level, clothes may not tumble properly and automatic sensor cycles may cause dryer...: Most installations require a minimum of 200 lbs. (90.7 kg). Left or right side exhaust 3/4"* (18 mm) 61/2" (165 mm) Power supply cord/cable Vent Water inlet 297/8"* (759 mm) 31/2"* (89 mm) 3/4"* (18 mm) 61/8"* (156 mm) 4 * Approx. LOCATION REQUIREMENTS Check code requirements. Add spacing...
Installation Instructions
Page 5
...provisions must determine the type of electrical connection you must be using a power supply cord: Use a UL listed power supply cord kit marked for use an extension cord. ■■If codes permit and a separate ground wire is used when the appliance is ...should be considered for ease of installation and servicing. ■■Additional clearances might be required for wall, door, floor moldings, and dryer venting. ■■Additional spacing should be considered. Louvered doors with clothes dryers. Recommended installation clearances (dryer only): 18" min. (457 mm)...
...provisions must determine the type of electrical connection you must be using a power supply cord: Use a UL listed power supply cord kit marked for use an extension cord. ■■If codes permit and a separate ground wire is used when the appliance is ...should be considered for ease of installation and servicing. ■■Additional clearances might be required for wall, door, floor moldings, and dryer venting. ■■Additional spacing should be considered. Louvered doors with clothes dryers. Recommended installation clearances (dryer only): 18" min. (457 mm)...