Installation Instructions
Page 3
...units, cabinet storage space located above the surface units should be located as shown in "Cabinet Dimensions" section so that they are accessible without requiring removal of the cooktop. ■ Provide cutout in the wall or floor where cooktop is to be installed must be sealed. ■... Cabinet opening dimensions that are minimum clearances. ■ Grounded electrical supply is located on the model/serial rating ...
...units, cabinet storage space located above the surface units should be located as shown in "Cabinet Dimensions" section so that they are accessible without requiring removal of the cooktop. ■ Provide cutout in the wall or floor where cooktop is to be installed must be sealed. ■... Cabinet opening dimensions that are minimum clearances. ■ Grounded electrical supply is located on the model/serial rating ...
Installation Instructions
Page 4
... - If cabinet has a drawer, a 4" (10.2 cm) depth clearance from upper cabinet to countertop within 24" (61 cm) of right rear corner of cutout I G J A. 30" (76.2 cm) on 30" models; 36" (91.4 cm) on 36" models B. Gas line opening - Locate within minimum ...J I . 29" (73.7 cm) on 30" models; 35¼" (89.5 cm) on 36" (91.4 cm) models C. 2⁷⁄₈" (7.3 cm) Cabinet Dimensions IMPORTANT: If installing a range hood or microwave hood combination above the cooktop, follow the range hood or microwave hood combination installation instructions for dimensional clearances...
... - If cabinet has a drawer, a 4" (10.2 cm) depth clearance from upper cabinet to countertop within 24" (61 cm) of right rear corner of cutout I G J A. 30" (76.2 cm) on 30" models; 36" (91.4 cm) on 36" models B. Gas line opening - Locate within minimum ...J I . 29" (73.7 cm) on 30" models; 35¼" (89.5 cm) on 36" (91.4 cm) models C. 2⁷⁄₈" (7.3 cm) Cabinet Dimensions IMPORTANT: If installing a range hood or microwave hood combination above the cooktop, follow the range hood or microwave hood combination installation instructions for dimensional clearances...
Dimension Guide
Page 1
...Hz., AC only, 15-amp fused, electrical circuit is required Because Whirlpool Corporation policy includes a continuous commitment to cooktop H. Combustible area above ...of unprotected wood or metal cabinet (24" [61 cm] minimum clearance if bottom of cutout I G J A. 21¹⁄₈" (53.7 cm) B. 30 77.0 ... notice. Cabinet floor: Anywhere within minimum horizontal clearances to improve Dimensions are for use TEFLON® tape. A smaller size pipe...174; Gas Built-in Cooktop PRODUCT MODEL NUMBERS GLS3074V GLS3675V W3CG3014X Gas Supply: This cooktop is factory set for planning ...
...Hz., AC only, 15-amp fused, electrical circuit is required Because Whirlpool Corporation policy includes a continuous commitment to cooktop H. Combustible area above ...of unprotected wood or metal cabinet (24" [61 cm] minimum clearance if bottom of cutout I G J A. 21¹⁄₈" (53.7 cm) B. 30 77.0 ... notice. Cabinet floor: Anywhere within minimum horizontal clearances to improve Dimensions are for use TEFLON® tape. A smaller size pipe...174; Gas Built-in Cooktop PRODUCT MODEL NUMBERS GLS3074V GLS3675V W3CG3014X Gas Supply: This cooktop is factory set for planning ...