Design Guide - Ventilation
Page 3
Install these hoods only with Thermador Blowers. *High heat tested to accommodate Pro Harmony® or Pro Rangetop 18,000 burners and griddle. †Pro Harmony Ranges and Pro Rangetops require a 40-...
Install these hoods only with Thermador Blowers. *High heat tested to accommodate Pro Harmony® or Pro Rangetop 18,000 burners and griddle. †Pro Harmony Ranges and Pro Rangetops require a 40-...
Design Guide - Ventilation
Page 5
... these hoods only with Thermador Blowers. *Compatible with Pro Grand Ranges, Pro Harmony Ranges and Professional Rangetops. COOKTOP and ventilation matrix Masterpiece® SERIES = PERFECT FIT = VIABLE OPTION 30" HMWN30FS WALL HOODS 36" HMWN36FS 48" HMWN48FS WALL HOODS WITH BLOWER 30" HMWB30FS 36" ...36-INCH INDUCTION / FREEDOM INDUCTION 30-INCH GAS COOKTOP 36-INCH GAS COOKTOP GLASS CANOPY HOOD WITH BLOWER 36" HGEW36FS DRAWER HOOD WITH BLOWER 36" HDDW36FS ISLAND HOODS WITH BLOWER 40" HMIB40HS 42" HPIB42HS 48" HPIB48HS* CUSTOM INSERTS 30" VCI230DS† 36" VCI236DS†...
... these hoods only with Thermador Blowers. *Compatible with Pro Grand Ranges, Pro Harmony Ranges and Professional Rangetops. COOKTOP and ventilation matrix Masterpiece® SERIES = PERFECT FIT = VIABLE OPTION 30" HMWN30FS WALL HOODS 36" HMWN36FS 48" HMWN48FS WALL HOODS WITH BLOWER 30" HMWB30FS 36" ...36-INCH INDUCTION / FREEDOM INDUCTION 30-INCH GAS COOKTOP 36-INCH GAS COOKTOP GLASS CANOPY HOOD WITH BLOWER 36" HGEW36FS DRAWER HOOD WITH BLOWER 36" HDDW36FS ISLAND HOODS WITH BLOWER 40" HMIB40HS 42" HPIB42HS 48" HPIB48HS* CUSTOM INSERTS 30" VCI230DS† 36" VCI236DS†...
Design Guide - Ventilation
Page 7
... • Included 4.9 • Included 5.2 • Included 5.2 VTR630D 5.2 VTR1030D 7.8 VTR1330E 9.5 •• VTI610D 5.8 •• VTI1010D 7.6 • VTN600CV2C 6.7 VTR630D 6.7 VTR1030D 10.2 • VTI610D 5.8 • VTI1010D 7.6 1T2o0taVlolAts,mp6s0 @ Hz Information BLOWER selection and duct guide PROFESSIONAL SERIES Blower CFM Type WALL HOODS ISLAND HOODS CUSTOM INSERTS Model No. Remote Inline...8226; 1000 • 600 1000 134 *Purchase separately at most hardware stores, unless otherwise indicated with a Thermador model number.
... • Included 4.9 • Included 5.2 • Included 5.2 VTR630D 5.2 VTR1030D 7.8 VTR1330E 9.5 •• VTI610D 5.8 •• VTI1010D 7.6 • VTN600CV2C 6.7 VTR630D 6.7 VTR1030D 10.2 • VTI610D 5.8 • VTI1010D 7.6 1T2o0taVlolAts,mp6s0 @ Hz Information BLOWER selection and duct guide PROFESSIONAL SERIES Blower CFM Type WALL HOODS ISLAND HOODS CUSTOM INSERTS Model No. Remote Inline...8226; 1000 • 600 1000 134 *Purchase separately at most hardware stores, unless otherwise indicated with a Thermador model number.
Design Guide - Ventilation
Page 8
... 6-Inch 8-Inch 10-Inch Hood Information Included Required* 6-Inch 8-Inch 10-Inch Vertical Horizontal Side & Down CRaepciarbciluiltaytion Roofplate Required Duct Size at Blower • • • • • • • • • • • • •...8226; • • • • • • • • • • • 1.800.735.4328 | THERMADOR.COM Transition with Backdraft Damper Duct Size at Discharge Discharge Direction • ••• • ••• • ••...
... 6-Inch 8-Inch 10-Inch Hood Information Included Required* 6-Inch 8-Inch 10-Inch Vertical Horizontal Side & Down CRaepciarbciluiltaytion Roofplate Required Duct Size at Blower • • • • • • • • • • • • •...8226; • • • • • • • • • • • 1.800.735.4328 | THERMADOR.COM Transition with Backdraft Damper Duct Size at Discharge Discharge Direction • ••• • ••• • ••...
Design Guide - Ventilation
Page 9
BLOWER options AND PRESSURE CURVES Integrated (MOUNTED ON HOOD) VTN600CV2C - 600 CFM VTN600F - 600 CFM VTN630C - 600 CFM VTN1080F - 1000 CFM VTN1000F - 1000 CFM VTN1030C - 1000 CFM 136
BLOWER options AND PRESSURE CURVES Integrated (MOUNTED ON HOOD) VTN600CV2C - 600 CFM VTN600F - 600 CFM VTN630C - 600 CFM VTN1080F - 1000 CFM VTN1000F - 1000 CFM VTN1030C - 1000 CFM 136
Design Guide - Ventilation
Page 10
These are made with 3 ft. straight duct. VENTILATION BLOWER options AND PRESSURE CURVES REMOTE (MOUNTED TO ROOF OR EXTERNAL WALL) VTR630D - 600 CFM VTR1030D - 1000 CFM VTR1330E - 1300 CFM INLINE (MOUNTED BETWEEN KITCHEN AND EXTERNAL WALL) VTI610D - 600 CFM VTI1010D - 1000 CFM NOTE: All measurements are NOT free blowing measurements. 1.800.735.4328 | THERMADOR.COM 137 straight duct, 90° bend followed by 1 ft.
These are made with 3 ft. straight duct. VENTILATION BLOWER options AND PRESSURE CURVES REMOTE (MOUNTED TO ROOF OR EXTERNAL WALL) VTR630D - 600 CFM VTR1030D - 1000 CFM VTR1330E - 1300 CFM INLINE (MOUNTED BETWEEN KITCHEN AND EXTERNAL WALL) VTI610D - 600 CFM VTI1010D - 1000 CFM NOTE: All measurements are NOT free blowing measurements. 1.800.735.4328 | THERMADOR.COM 137 straight duct, 90° bend followed by 1 ft.
Design Guide - Ventilation
Page 12
... in one easy-to-remove, dishwasher-safe element • Ideal in island applications • 600 CFM recirculation kit option with integrated blower is not available • Dishwasher-safe, stainless steel filters • Slim and sleek design that does not obstruct the views beyond ... • Halogen lighting • Dishwasher-safe, stainless steel frame filters • Automatic Clean Filter Reminder light ISLAND hoods Thermador Island Hoods offer excellent overall efficiency in cooking and venting power or the Masterpiece® Series for all types of our two sophisticated...
... in one easy-to-remove, dishwasher-safe element • Ideal in island applications • 600 CFM recirculation kit option with integrated blower is not available • Dishwasher-safe, stainless steel filters • Slim and sleek design that does not obstruct the views beyond ... • Halogen lighting • Dishwasher-safe, stainless steel frame filters • Automatic Clean Filter Reminder light ISLAND hoods Thermador Island Hoods offer excellent overall efficiency in cooking and venting power or the Masterpiece® Series for all types of our two sophisticated...
Design Guide - Ventilation
Page 15
... ventilation models include delayed shut-off to tackle lingering odors. (Except HMWB30FS, HMWB36FS) Powerful Ventilation Breathe deeply with all Thermador ventilation filters are meticulously crafted for easy cleanup. Select Professional Series for the ultimate in Time-to-Clean-Filter reminder light... filters maximize grease capture without affecting flow, and they're dishwasher-safe for both function and design. Remote blowers require a 5-wire installation. Thermador Wall Hoods are available in this design guide. An appropriatelysized, UL-listed conduit connector must comply with the...
... ventilation models include delayed shut-off to tackle lingering odors. (Except HMWB30FS, HMWB36FS) Powerful Ventilation Breathe deeply with all Thermador ventilation filters are meticulously crafted for easy cleanup. Select Professional Series for the ultimate in Time-to-Clean-Filter reminder light... filters maximize grease capture without affecting flow, and they're dishwasher-safe for both function and design. Remote blowers require a 5-wire installation. Thermador Wall Hoods are available in this design guide. An appropriatelysized, UL-listed conduit connector must comply with the...
Design Guide - Ventilation
Page 16
...that may be moved and the length and location of installation. VENTILATION - Before installing a Thermador Wall Hood, be sure to be difficult to reduce noise in the kitchen. Inline Blowers (VTI series) To minimize noise in different eras. Hood Width The hood width should ... important factor in the same room, can be an appealing option. Integrated Blowers (VTN series) These blowers are mounted along the duct line anywhere between 7'6" (or 90") to the installation manual for Thermador's Professional and Masterpiece® Series Hoods. This option allows you have selected ...
...that may be moved and the length and location of installation. VENTILATION - Before installing a Thermador Wall Hood, be sure to be difficult to reduce noise in the kitchen. Inline Blowers (VTI series) To minimize noise in different eras. Hood Width The hood width should ... important factor in the same room, can be an appealing option. Integrated Blowers (VTN series) These blowers are mounted along the duct line anywhere between 7'6" (or 90") to the installation manual for Thermador's Professional and Masterpiece® Series Hoods. This option allows you have selected ...
Design Guide - Ventilation
Page 17
...2 120V AC, 60Hz PH36GS / PH42GS / PH48GS / PH54GS Performance - Three fan speeds - Auto function senses heat from Inline, Remote or Integrated Blowers - Blowers sold separately - Hood includes filters, backdraft damper and transition - Approved by CSA/UL for damp environments Design - 27" depth hood is a ... easily removed - Filter systems are highly efficient at capturing grease - Vertical or horizontal ducting direction - Seven different blowers to choose from the lineup according to keep hot at Discharge Ducting Direction Dishwasher-safe Filters Halogen Lighting 12 Volt, 20 ...
...2 120V AC, 60Hz PH36GS / PH42GS / PH48GS / PH54GS Performance - Three fan speeds - Auto function senses heat from Inline, Remote or Integrated Blowers - Blowers sold separately - Hood includes filters, backdraft damper and transition - Approved by CSA/UL for damp environments Design - 27" depth hood is a ... easily removed - Filter systems are highly efficient at capturing grease - Vertical or horizontal ducting direction - Seven different blowers to choose from the lineup according to keep hot at Discharge Ducting Direction Dishwasher-safe Filters Halogen Lighting 12 Volt, 20 ...
Design Guide - Ventilation
Page 18
...VTN1030C - 1000 CFM 1.800.735.4328 | THERMADOR.COM 145 Both vertical and horizontal discharge is shipped ready for additional specifications. The hood is possible with Remote Blowers VTR1030D and VTR1330E BLOWER OPTIONS REMOTE VTR630D - 600 CFM Use RFPLT600 in roof-mount ...PH36GS / PH42GS / PH48GS / PH54GS INSTALLATION OPTIONS Thermador Wall Hoods may be installed above a Thermador Cooktop or Range to the appropriate section for vertical discharge. REMOTE BLOWER ACCESSORIES RFPLT600 For use with Remote Blower VTR630D RFPLT1000 For use with either mounting method. Refer...
...VTN1030C - 1000 CFM 1.800.735.4328 | THERMADOR.COM 145 Both vertical and horizontal discharge is shipped ready for additional specifications. The hood is possible with Remote Blowers VTR1030D and VTR1330E BLOWER OPTIONS REMOTE VTR630D - 600 CFM Use RFPLT600 in roof-mount ...PH36GS / PH42GS / PH48GS / PH54GS INSTALLATION OPTIONS Thermador Wall Hoods may be installed above a Thermador Cooktop or Range to the appropriate section for vertical discharge. REMOTE BLOWER ACCESSORIES RFPLT600 For use with Remote Blower VTR630D RFPLT1000 For use with either mounting method. Refer...
Design Guide - Ventilation
Page 19
...collection trays are easily removed - Powerfully Quiet® ventilation systems - Blowers sold separately - Seven different blowers to choose from the lineup according to cooking needs - Choose from Inline, Remote or Integrated Blowers - 10" Round duct size - Vertical or horizontal ducting direction - ...after 40 hours of operation - Filter systems are highly efficient at serving temperature. - Includes stainless steel backguard and two shelves. See Blower Options Table 10" Vertical or Horizontal Commercial-Style Stainless Steel Baffle Filter 30" / 36"- 2 Bulbs 48"- 4 Bulbs 120V AC,...
...collection trays are easily removed - Powerfully Quiet® ventilation systems - Blowers sold separately - Seven different blowers to choose from the lineup according to cooking needs - Choose from Inline, Remote or Integrated Blowers - 10" Round duct size - Vertical or horizontal ducting direction - ...after 40 hours of operation - Filter systems are highly efficient at serving temperature. - Includes stainless steel backguard and two shelves. See Blower Options Table 10" Vertical or Horizontal Commercial-Style Stainless Steel Baffle Filter 30" / 36"- 2 Bulbs 48"- 4 Bulbs 120V AC,...
Design Guide - Ventilation
Page 20
... - 1000 CFM VTR1330E - 1300 CFM REMOTE BLOWER ACCESSORIES RFPLT600 For use with Remote Blower VTR630D INLINE (Mounted between the hood and ceiling. VENTILATION - WALL HOODS VENTILATION 24-INCH DEPTH WALL HOOD (30"/36"/48") PH30HS / PH36HS / PH48HS INSTALLATION OPTIONS Thermador Wall Hoods may be installed above a Thermador Cooktop or Range to fill the space...
... - 1000 CFM VTR1330E - 1300 CFM REMOTE BLOWER ACCESSORIES RFPLT600 For use with Remote Blower VTR630D INLINE (Mounted between the hood and ceiling. VENTILATION - WALL HOODS VENTILATION 24-INCH DEPTH WALL HOOD (30"/36"/48") PH30HS / PH36HS / PH48HS INSTALLATION OPTIONS Thermador Wall Hoods may be installed above a Thermador Cooktop or Range to fill the space...
Design Guide - Ventilation
Page 21
... wide PA36JBS 36" wide PA48JBS 48" wide 148 - Stainless steel finish - Perfect for hard to duct installations - Use with 600 CFM blowers only Replacement Charcoal Filters CHFILT3036 For use with kit RECIRC_ _FS (max 600 CFM) - Three fan speeds - Delayed shut-off tackles lingering odors... Filters Halogen Lighting 120 Volt, 50 Watt Max., GU10 Base, Not Included Electrical 30" / 36" / 48" 30"- 600 CFM Blower Included 36"- 1000 CFM Blower Included 48"- 1000 CFM Blower Included 10" Round Vertical Low-Profile Baffle 30" / 36"- 2 Bulbs 48"- 3 Bulbs 120V AC, 60Hz HPWB30FS / HPWB36FS / HPWB48FS...
... wide PA36JBS 36" wide PA48JBS 48" wide 148 - Stainless steel finish - Perfect for hard to duct installations - Use with 600 CFM blowers only Replacement Charcoal Filters CHFILT3036 For use with kit RECIRC_ _FS (max 600 CFM) - Three fan speeds - Delayed shut-off tackles lingering odors... Filters Halogen Lighting 120 Volt, 50 Watt Max., GU10 Base, Not Included Electrical 30" / 36" / 48" 30"- 600 CFM Blower Included 36"- 1000 CFM Blower Included 48"- 1000 CFM Blower Included 10" Round Vertical Low-Profile Baffle 30" / 36"- 2 Bulbs 48"- 3 Bulbs 120V AC, 60Hz HPWB30FS / HPWB36FS / HPWB48FS...
Design Guide - Ventilation
Page 22
... or suspended from a cabinet. straight duct at exhaust. To obtain the necessary installation height above a Thermador Cooktop or Range to support the weight of this hood. A ductless, recirculation installation is possible with 3 ft. HOOD DIMENSIONS BLOWER PRESSURE CURVES HPWB30FS HPWB36FS HPWB48FS NOTE: All measurements are designed to be structurally joined to the...
... or suspended from a cabinet. straight duct at exhaust. To obtain the necessary installation height above a Thermador Cooktop or Range to support the weight of this hood. A ductless, recirculation installation is possible with 3 ft. HOOD DIMENSIONS BLOWER PRESSURE CURVES HPWB30FS HPWB36FS HPWB48FS NOTE: All measurements are designed to be structurally joined to the...
Design Guide - Ventilation
Page 23
... HOOD (30"/36"/48") HMWN30FS / HMWN36FS / HMWN48FS MASTERPIECE HMWN30FS - 30-Inch HMWN36FS - 36-Inch HMWN48FS - 48-Inch SPECIFICATIONS Available Hood Widths Blower Duct Size at capturing grease - Powerfully Quiet® ventilation systems - 10" Round duct size - Vertical ducting direction - Hood includes filters,...PA36JBS 36" wide PA48JBS 48" wide 150 - Stainless steel finish - Perfect for hard to duct installations - Use with 600 CFM blowers only Replacement Charcoal Filters CHFILT3036 For use with kit RECIRC_ _FS (max 600 CFM) - Three fan speeds plus 10 minute high-power operation...
... HOOD (30"/36"/48") HMWN30FS / HMWN36FS / HMWN48FS MASTERPIECE HMWN30FS - 30-Inch HMWN36FS - 36-Inch HMWN48FS - 48-Inch SPECIFICATIONS Available Hood Widths Blower Duct Size at capturing grease - Powerfully Quiet® ventilation systems - 10" Round duct size - Vertical ducting direction - Hood includes filters,...PA36JBS 36" wide PA48JBS 48" wide 150 - Stainless steel finish - Perfect for hard to duct installations - Use with 600 CFM blowers only Replacement Charcoal Filters CHFILT3036 For use with kit RECIRC_ _FS (max 600 CFM) - Three fan speeds plus 10 minute high-power operation...
Design Guide - Ventilation
Page 24
... be structurally joined to the wall studs to the appropriate section for use with Remote Blowers VTR1030D and VTR1330E 1.800.735.4328 | THERMADOR.COM 151 Accessory 6" and/or 12" duct covers are used to roof or external wall) VTR630D - 600 CFM VTR1030D - 1000 CFM VTR1330E - 1300 CFM INLINE (Mounted between the hood and...
... be structurally joined to the wall studs to the appropriate section for use with Remote Blowers VTR1030D and VTR1330E 1.800.735.4328 | THERMADOR.COM 151 Accessory 6" and/or 12" duct covers are used to roof or external wall) VTR630D - 600 CFM VTR1030D - 1000 CFM VTR1330E - 1300 CFM INLINE (Mounted between the hood and...
Design Guide - Ventilation
Page 25
... - 30-Inch HMWB36FS - 36-Inch SPECIFICATIONS Available Hood Widths Blower Duct Size at Discharge Ducting Direction Dishwasher-safe Filters Halogen Lighting 120 Volt, 50 Watt Max., GU10 Base, Not Included 30" / 36" 600 CFM Blower Included 10" Round Vertical Low-Profile Baffle 2 Bulbs Electrical 120V... AC, 60Hz HMWB30FS / HMWB36FS Performance - 600 CFM Integrated Blower included - Recirculation possible with kit RECIRC_ _FS (max 600 CFM) - Three fan...
... - 30-Inch HMWB36FS - 36-Inch SPECIFICATIONS Available Hood Widths Blower Duct Size at Discharge Ducting Direction Dishwasher-safe Filters Halogen Lighting 120 Volt, 50 Watt Max., GU10 Base, Not Included 30" / 36" 600 CFM Blower Included 10" Round Vertical Low-Profile Baffle 2 Bulbs Electrical 120V... AC, 60Hz HMWB30FS / HMWB36FS Performance - 600 CFM Integrated Blower included - Recirculation possible with kit RECIRC_ _FS (max 600 CFM) - Three fan...
Design Guide - Ventilation
Page 26
... duct at exhaust. Hood installation height above a cooktop or range can be installed above a Thermador Professional Cooktop or Range, consult the appliance's installation manual. Accessory 6" and/or 12" duct covers are used for additional specifications. HOOD DIMENSIONS BLOWER PRESSURE CURVES HMWB30FS HMWB36FS NOTE: All measurements are designed to be used over indoor...
... duct at exhaust. Hood installation height above a cooktop or range can be installed above a Thermador Professional Cooktop or Range, consult the appliance's installation manual. Accessory 6" and/or 12" duct covers are used for additional specifications. HOOD DIMENSIONS BLOWER PRESSURE CURVES HMWB30FS HMWB36FS NOTE: All measurements are designed to be used over indoor...
Design Guide - Ventilation
Page 30
...air systems when using a 10" duct, Thermador recommends not exceeding 150 feet of the cooktop or range, measured in BTU, is in the same room, can sometimes vary by raising or lowering your duct line (in the kitchen, these blowers can vary between the kitchen and the exterior... capacity to 36" above the cooking surface). If you have a blower included, one can be needed. An exterior installation may require additional CFM. Consult your HVAC professional for additional warranty details. 1.800.735.4328 | THERMADOR.COM 157 For long duct runs with the exact power you have ...
...air systems when using a 10" duct, Thermador recommends not exceeding 150 feet of the cooktop or range, measured in BTU, is in the same room, can sometimes vary by raising or lowering your duct line (in the kitchen, these blowers can vary between the kitchen and the exterior... capacity to 36" above the cooking surface). If you have a blower included, one can be needed. An exterior installation may require additional CFM. Consult your HVAC professional for additional warranty details. 1.800.735.4328 | THERMADOR.COM 157 For long duct runs with the exact power you have ...