Popular Thermador VCI230DS Manual Pages

Design Guide - Ventilation - Page 14

... 145 CHOOSINg THE RIgHT CFm The power of a hood and cooktop or range. Also, always consult with the installation manual packed with 600 CFM may require additional CFM. Before selecting a Thermador Hood, check the available installation space and any extra space that needs to the installation manual for each side is mounted too low, it creates back pressure...
Design Guide - Ventilation - Page 26

..., electric, or induction cooktop to create a convenient cooking center. Refer to the installation manual for Thermador's Masterpiece® Series Hoods. DISTANCE FROM COOKINg SURFACE Proper mounting height is mounted too low, it creates back pressure/air turbulence and reduces performance. If a hood is very important. AVAILABLE CEILINg HEIgHT The standard ceiling height can also be...
Design Guide - Ventilation - Page 37

... and features a stainless steel design with all applicable local codes. POWERFULLY QUIET™ OPERATION Steam, smoke and odors are no problem for easy-clean maintenance. All of our island hoods are adjustable to suit a range of ceiling heights. 168 ELECTRICAL SPECIFICATIONS Be sure your fingertips. MODEL HNI42YS, HNI48YS, HNI54YS, HGSI42TS REQUIRED CIRCUIT BREAKER 120...
Design Guide - Ventilation - Page 38

... to the installation manual for each ...codes may be mounted higher. Before installing a Thermador Island Hood, be no less than specified CFM of make-up air systems when using Thermador's stainless steel duct cover accessories. Before selecting a Thermador Hood, check the available installation space and any extra space that will vary based on each hood and cooktop/ range model...
Design Guide - Ventilation - Page 40

..., VTR1330E Model No. To obtain the necessary installation height above a Thermador Professional Cooktop or Range to the appropriate section for further details. Refer to create a convenient cooking center. Hood installation height above a cooktop can vary. A blower must be installed above a Thermador Cooktop or Range, consult the appliance's installation manual. These hoods are...
Design Guide - Ventilation - Page 42

... height above a cooktop can vary. VENTILATION - Hood installation height above a Thermador Cooktop or Range, consult the appliance's installation manual. These hoods are suspended from the ceiling. A 400 CFM blower is included. 1.800.735.4328 | THERMADOR.COM 173 Refer to be installed above a Thermador non-professional gas, electric, or induction cooktop to create a convenient...
Design Guide - Ventilation - Page 46

... hood or downdraft system with multiple turns and bends, consider using a 10" duct, Thermador recommends not exceeding 150 feet of 30", unless otherwise noted. Local building codes ...design guide provides key features, product dimensions and installation specifications. WARRANTy Limited warranty parts and labor (1 year) See page 294 for additional specifications. If a hood is ...
Design Guide - Ventilation - Page 48

... of the rangetop or range prior to product and by manufacturer. CUSTOM INSERTS VENTILATION CUSTOM INSERT (30"/36"/48") Models: VCI230DS, VCI236DS, VCI248DS INSTALLATION OPTIONS Thermador Custom Hood Inserts within custom hood applications create a seamless design with Remote Blowers VTR630D, VTR1030D and VTR1330E Combinations Roofplate RFPLT600 RFPLT1000 Remote Blower VTR630D VTR1030D...
Design Guide - Ventilation - Page 50

...CUSTOM INSERT WITH BLOWER (21"/29") Models: VCI21CS, VCI29CS INSTALLATION OPTIONS Thermador Custom Hood Inserts within custom hood applications create a seamless design with wall or island applications. Hood installation height above a Thermador Cooktop, consult the appliance's installation manual. VENTILATION - Thermador Masterpiece® Series Custom Hood Inserts may be used for additional...
Design Guide - Ventilation - Page 53

... option. ELECTRICAL SPECIFICATIONS Be sure your duct line (in one can be mounted on the volume of air that needs to your Thermador Downdraft Hood is now available for complete details before installing. 184 Thermador Downdraft Hoods may be the same width as possible. Installation, electrical connections and grounding must comply with the odor- MODEL UCVM30FS, UCVM36FS...
Ventilation Guide - Page 4

...Hood and downdraft ventilation systems handle high heat and exhaust needs to maintain a safe cooking area ODORS No need to remember. Thermador. That's why choosing a quality ventilation system by Thermador is one of our two sophisticated appliance... can end up your kitchen with amazing efficiency • Some models include delayed shutoff to tackle lingering odors • Switching on ...
Ventilation Guide - Page 5

...or 90") to the installation manual for each hood and cooktop/range model for proper hood mounting heights. 30" minimum 2. SPECIAL NOTE Always allow access to the blower for serviceability, should be more ...to top of hood) minimum for proper hood installation Cover or cabinetry 11" THERMADOR hood height 30" minimum required distance from rangetop to bottom of hood 36" countertop height...
User Manual - Page 5

... repairs may find descriptions of individual features that do not apply to your specific appliance. ❑ This hood complies with a different heating system that the negative pressure in the kitchen vapors. ❑ The kitchen is located over a gas cooktop, operate the hood at high settings for a prolonged period of cooking appliances, such as cooktops and ovens. Note...
User Manual - Page 9

... bulbs have been inserted correctly. Switch off the hood and unplug the power cord, or switch off . 2. REPLACING THE BULBS ṇ CAUTION: Avoid risk of burns. Halogen bulbs become very hot and remain hot for complaints that has not been resolved to : Customer Support, BSH Home Appliances, Corp. 5551 McFadden Ave., Huntington Beach, CA...
User Manual - Page 10

... may vary from the date of installation or date of occupancy of a new, previously unoccupied dwelling, any repairs and replacement of parts proven to use . It does not cover commercial use in Canada. Should the appliance be sold by an unauthorized agency. This warranty gives you specific legal rights, and you . Service visits to: ❑ Teach you...

Thermador VCI230DS Reviews

Do you have an experience with the Thermador VCI230DS that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Thermador yet.

Popular Thermador VCI230DS Search Terms

The following terms are frequently used to search for Thermador VCI230DS support:

Ask a New Question
Use the box below to post a new question about Thermador VCI230DS.
Manuals / Documents
Download any of our Thermador VCI230DS manuals for free!

We have the following 4 documents available for the Thermador VCI230DS:
  • Design Guide - Ventilation
  • Ventilation Guide
  • Installation Instructions
  • User Manual

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Thermador Manuals

Find free Thermador VCI230DS manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Thermador Reviews

View thousands of Thermador VCI230DS user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Thermador customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Thermador customer service rankings, employee comments and much more from our sister site.

Thermador Recalls

Find comprehensive Thermador recall information updated hourly on RecallOwl.com.