Power packs
Page 2
... is displayed after the accupack has been fully charged in correspondence to the remaining accupack capacity. The updated capacity is calculated during normal operation until the Low Batt indication lights up. Power packs for the SK 50, SK 250 and SK 3063 B 50-2 and B 250-2 battery pack: >5 y 3-step LC display for (remaining) battery capacity y Reliable Low Batt indication 5 y Protection against total...
... is displayed after the accupack has been fully charged in correspondence to the remaining accupack capacity. The updated capacity is calculated during normal operation until the Low Batt indication lights up. Power packs for the SK 50, SK 250 and SK 3063 B 50-2 and B 250-2 battery pack: >5 y 3-step LC display for (remaining) battery capacity y Reliable Low Batt indication 5 y Protection against total...
Instructions for use
Page 4
... 2. B 50 / B 250 QUICK-CHANGE ENERGY PACK 21 4.2. TECHNICAL DATA SK 50 VHF 28 12. USING FOR THE FIRST TIME 21 4.1. CONTROLS AND CONNECTIONS 20 3. SWITCHING ON 24 7. LICENSING REGULATIONS 26 10. TECHNICAL DATA SK 250 VHF 29 18 CHANNEL SELECTION 24 6. MICROPHONE SELECTION 21 4. CONTENTS 1. SENSITIVITY SETTING 25 8. TECHNICAL DATA SK 50 UHF / SK 250 UHF 27 11. BA 50 / BA 250 QUICK-CHANGE...
... 2. B 50 / B 250 QUICK-CHANGE ENERGY PACK 21 4.2. TECHNICAL DATA SK 50 VHF 28 12. USING FOR THE FIRST TIME 21 4.1. CONTROLS AND CONNECTIONS 20 3. SWITCHING ON 24 7. LICENSING REGULATIONS 26 10. TECHNICAL DATA SK 250 VHF 29 18 CHANNEL SELECTION 24 6. MICROPHONE SELECTION 21 4. CONTENTS 1. SENSITIVITY SETTING 25 8. TECHNICAL DATA SK 50 UHF / SK 250 UHF 27 11. BA 50 / BA 250 QUICK-CHANGE...
Instructions for use
Page 5
... be established, which is the case with a connected microphone, the transmitter can be used as is characterised by excellent operational reliability and supreme transmission quality. BRIEF DESCRIPTION MODELS SK 50 UHF SK 250 UHF SK 50 VHF (1) SK 50 VHF (2) SK 50 VHF (3) SK 50 VHF (4) SK 50 VHF (5) SK 250 VHF (1) SK 250 VHF (2) SK 250 VHF (3) FREQUENCY RANGE 450 bis 960 MHz 450 bis 960 MHz 138 bis 160 MHz...
... be established, which is the case with a connected microphone, the transmitter can be used as is characterised by excellent operational reliability and supreme transmission quality. BRIEF DESCRIPTION MODELS SK 50 UHF SK 250 UHF SK 50 VHF (1) SK 50 VHF (2) SK 50 VHF (3) SK 50 VHF (4) SK 50 VHF (5) SK 250 VHF (1) SK 250 VHF (2) SK 250 VHF (3) FREQUENCY RANGE 450 bis 960 MHz 450 bis 960 MHz 138 bis 160 MHz...
Instructions for use
Page 6
CONTROLS AND CONNECTIONS 7 1 6 2 5 4 3 1 ANTENNA SOCKET 2 CHANNEL SELECTION SWITCH 3 OPERATING TIME DISPLAY 4 ON / OFF SWITCH 5 OPERATING / PEAK DEVIATION INDICATOR 6 SENSITIVITY SELECTOR SWITCH FOR MICROPHONE INPUT 7 MICROPHONE INPUT 20 2.
CONTROLS AND CONNECTIONS 7 1 6 2 5 4 3 1 ANTENNA SOCKET 2 CHANNEL SELECTION SWITCH 3 OPERATING TIME DISPLAY 4 ON / OFF SWITCH 5 OPERATING / PEAK DEVIATION INDICATOR 6 SENSITIVITY SELECTOR SWITCH FOR MICROPHONE INPUT 7 MICROPHONE INPUT 20 2.
Instructions for use
Page 7
... microphones are equipped with a special Lemo plug. FIG. 1 BATTERY CONTROL DISPLAY 100 % 50 % 10 % STARTS TO BLINK IF THE REMAINING OPERATING TIME FALLS BELOW. 30 MIN. 21 The voltage necessary to be connected through an external coupling condenser of the quick-change energy pack is disconnected by unscrewing the threaded collar. USING FOR THE FIRST TIME 4.1. B 50 / B 250 QUICK-CHANGE...
... microphones are equipped with a special Lemo plug. FIG. 1 BATTERY CONTROL DISPLAY 100 % 50 % 10 % STARTS TO BLINK IF THE REMAINING OPERATING TIME FALLS BELOW. 30 MIN. 21 The voltage necessary to be connected through an external coupling condenser of the quick-change energy pack is disconnected by unscrewing the threaded collar. USING FOR THE FIRST TIME 4.1. B 50 / B 250 QUICK-CHANGE...
Instructions for use
Page 8
FIG. 2 QUICK-CHANGE ENERGY PACK B 50 FIG. 3 QUICK-CHANGE ENERGY PACK B 250 + + + + + CLOSE COVER NOTE: ALKALINE-MANGANESE BATTERIES OF THE "MIGNON" LRC AA TYPE ARE TO BE USED EXCLUSIVELY. PERFECT FUNCTIONING OFTHE TRANSMITTER IS GUARANTEED ONLY WITH THIS TYPE OFBATTERY. 22
FIG. 2 QUICK-CHANGE ENERGY PACK B 50 FIG. 3 QUICK-CHANGE ENERGY PACK B 250 + + + + + CLOSE COVER NOTE: ALKALINE-MANGANESE BATTERIES OF THE "MIGNON" LRC AA TYPE ARE TO BE USED EXCLUSIVELY. PERFECT FUNCTIONING OFTHE TRANSMITTER IS GUARANTEED ONLY WITH THIS TYPE OFBATTERY. 22
Instructions for use
Page 9
..., simply let the quick-change energy pack. 4.2. BA 50 / BA 250 QUICK-CHANGE ENERGY PACK The LCD display on the front side of the batteries or the rechargeable batteries to the visual display on the receiver display. FIG. 4 RECHARGEABLE BATTERY DISPLAY 100 % 80 % 60 % 40 % 20 % STARTS TO BLINK IF THE REMAINING OPERATING TIME FALLS BELOW 30 MIN...
..., simply let the quick-change energy pack. 4.2. BA 50 / BA 250 QUICK-CHANGE ENERGY PACK The LCD display on the front side of the batteries or the rechargeable batteries to the visual display on the receiver display. FIG. 4 RECHARGEABLE BATTERY DISPLAY 100 % 80 % 60 % 40 % 20 % STARTS TO BLINK IF THE REMAINING OPERATING TIME FALLS BELOW 30 MIN...
Instructions for use
Page 10
... WITH THE QUICK-CHANGE ENERGY PACK FIG. 6 SK 50 SK 50-UHF SK 50-UHF SK 50-UHF SK 50-UHF B 50 B BA 50 BA 250 250 SK 250 SK 250-UHF SK 250-UHF SK 250-UHF SK 250-UHF B 50 B BA 50 BA 250 250 The SK 250 / B 50 and SK 250 / BA 50 combinations are not possible because the power of the battery / rechargeable battery pack is switched on by moving the operating switch 4 into...
... WITH THE QUICK-CHANGE ENERGY PACK FIG. 6 SK 50 SK 50-UHF SK 50-UHF SK 50-UHF SK 50-UHF B 50 B BA 50 BA 250 250 SK 250 SK 250-UHF SK 250-UHF SK 250-UHF SK 250-UHF B 50 B BA 50 BA 250 250 The SK 250 / B 50 and SK 250 / BA 50 combinations are not possible because the power of the battery / rechargeable battery pack is switched on by moving the operating switch 4 into...
Instructions for use
Page 11
... guide values have proven themselves for the adjustment of approx. 125 %. To attach the transmitter with a receiver which the transmitter can be attached to the waistband or to adapt the gain of the microphone input in combination with the connections facing downwards, simply reverse the clips. SENSITIVITY SELECTOR SWITCH The sensitivity selector switch 6 can also be used...
... guide values have proven themselves for the adjustment of approx. 125 %. To attach the transmitter with a receiver which the transmitter can be attached to the waistband or to adapt the gain of the microphone input in combination with the connections facing downwards, simply reverse the clips. SENSITIVITY SELECTOR SWITCH The sensitivity selector switch 6 can also be used...
Instructions for use
Page 12
LICENSING REGULATIONS The type plate contains the channel data and the transmit frequency data as well as the BZT approval, which you require for your application for the licence from the Post Office. It is located on the underside of the device. 26 FIG, 7 Note: The transmitter can also be attached so that the cable and antenna point downwards. 9.
LICENSING REGULATIONS The type plate contains the channel data and the transmit frequency data as well as the BZT approval, which you require for your application for the licence from the Post Office. It is located on the underside of the device. 26 FIG, 7 Note: The transmitter can also be attached so that the cable and antenna point downwards. 9.
Instructions for use
Page 13
... and emmissions Modulation Nominal / peak deviation Compander Input sensitivity for peak deviation Audio frequency range Dynamics THD Connections Dimensions with power pack Weight with power pack SK 50 UHF / SK 250 UHF 16 450 - 960 MHz 24 MHz ± 5 ppm < 4 nW FM ± 40 kHz / ± 56 kHz Sennheiser HiDyn plus 13.2 mV - 1.55 V 8-position switch 70 Hz - 20 kHz...
... and emmissions Modulation Nominal / peak deviation Compander Input sensitivity for peak deviation Audio frequency range Dynamics THD Connections Dimensions with power pack Weight with power pack SK 50 UHF / SK 250 UHF 16 450 - 960 MHz 24 MHz ± 5 ppm < 4 nW FM ± 40 kHz / ± 56 kHz Sennheiser HiDyn plus 13.2 mV - 1.55 V 8-position switch 70 Hz - 20 kHz...
Instructions for use
Page 14
... peak deviation Audio frequency range Dynamics THD Connections Dimensions with power pack Weight with power pack RF output power Operating time with primary cells Operating time with rechargeable battery Delivery includes 28 SK 50 VHF 16 SK 50 VHF (1) SK 50 VHF (2) SK 50 VHF (3) SK 50 VHF (4) SK 50 VHF (5) 138 ... 160 MHz 153 ... 181 MHz 174 ... 202 MHz 195 ... 223 MHz 223 ... 260 MHz SK 50 VHF (1) SK 50 VHF (2) SK 50 VHF (3) SK 50 VHF (4) SK 50 VHF (5) 22...
... peak deviation Audio frequency range Dynamics THD Connections Dimensions with power pack Weight with power pack RF output power Operating time with primary cells Operating time with rechargeable battery Delivery includes 28 SK 50 VHF 16 SK 50 VHF (1) SK 50 VHF (2) SK 50 VHF (3) SK 50 VHF (4) SK 50 VHF (5) 138 ... 160 MHz 153 ... 181 MHz 174 ... 202 MHz 195 ... 223 MHz 223 ... 260 MHz SK 50 VHF (1) SK 50 VHF (2) SK 50 VHF (3) SK 50 VHF (4) SK 50 VHF (5) 22...
Instructions for use
Page 15
...Audio frequency range Dynamics THD Connections Dimensions with power pack Weight with power pack RF output power Operating time with primary cells Operating time with rechargeable battery Delivery includes SK 250 VHF 16 SK 250 VHF (1) 138 ... 170 MHz SK 250 VHF (2) 170 ... 225 MHz SK 250 VHF (3) 210 ... 260 MHz SK 250 VHF (1) 38 MHz SK 250 VHF (2) 55 MHz SK 250 VHF (3) 50... / BA 250 250 mW / -1 dB B 50: cannot be used B 250: > 2.5 h BA 50: cannot be used BA 250: > 2.5 h 1 SK 250 VHF body-pack transmitter 1 marking set 1 antenna (aligned) 1 instructions for use Erros and omissions excepted.
...Audio frequency range Dynamics THD Connections Dimensions with power pack Weight with power pack RF output power Operating time with primary cells Operating time with rechargeable battery Delivery includes SK 250 VHF 16 SK 250 VHF (1) 138 ... 170 MHz SK 250 VHF (2) 170 ... 225 MHz SK 250 VHF (3) 210 ... 260 MHz SK 250 VHF (1) 38 MHz SK 250 VHF (2) 55 MHz SK 250 VHF (3) 50... / BA 250 250 mW / -1 dB B 50: cannot be used B 250: > 2.5 h BA 50: cannot be used BA 250: > 2.5 h 1 SK 250 VHF body-pack transmitter 1 marking set 1 antenna (aligned) 1 instructions for use Erros and omissions excepted.
Instructions for use
Page 20
KG 30900 Wedemark, Germany Phone +49 (5130) 600 0 Fax +49 (5130) 600 300 www.sennheiser.com Printed in Germany Publ. 04/05 48208/A07 Sennheiser electronic GmbH & Co.
KG 30900 Wedemark, Germany Phone +49 (5130) 600 0 Fax +49 (5130) 600 300 www.sennheiser.com Printed in Germany Publ. 04/05 48208/A07 Sennheiser electronic GmbH & Co.
Product Sheet
Page 1
... Technical Data SK 50 UHF-a RF output power 50 mW (-3 dB) Transmission frequencies 16 Frequency range 450-960 MHz Switching bandwidth 24 MHz Modulation wideband FM Nominal/peak deviation 40 kHz / ± 56 kHz Noise reduction system HiDyn plus ™ noise reduction system j RF output power 50 mW j Delivery includes: 1 SK 50 bodypack transmitter, 1 channel switcher, 1 set of colour-coded identification markers...
... Technical Data SK 50 UHF-a RF output power 50 mW (-3 dB) Transmission frequencies 16 Frequency range 450-960 MHz Switching bandwidth 24 MHz Modulation wideband FM Nominal/peak deviation 40 kHz / ± 56 kHz Noise reduction system HiDyn plus ™ noise reduction system j RF output power 50 mW j Delivery includes: 1 SK 50 bodypack transmitter, 1 channel switcher, 1 set of colour-coded identification markers...
Product Sheet
Page 2
... of the SK 50 / SK 250 Recommended Accessories for SK 50 / SK 250 j B 50-1 battery box for 2 AA size batteries (only for SK 50) j B 250-1 battery box for 3 AA size batteries j BA 50-1 accupack with 2 NiMH cells (only for SK 50) j BA 250-1 accupack with 3 NiMH cells j L 50 charger for 2 accupacks j DCA 50 power adaptor j NT 50 plug-in mains unit for 4 chargers* j SK 50 T protection bag, beige j MKE 2-4 Gold-C clip-on microphone, omni...
... of the SK 50 / SK 250 Recommended Accessories for SK 50 / SK 250 j B 50-1 battery box for 2 AA size batteries (only for SK 50) j B 250-1 battery box for 3 AA size batteries j BA 50-1 accupack with 2 NiMH cells (only for SK 50) j BA 250-1 accupack with 3 NiMH cells j L 50 charger for 2 accupacks j DCA 50 power adaptor j NT 50 plug-in mains unit for 4 chargers* j SK 50 T protection bag, beige j MKE 2-4 Gold-C clip-on microphone, omni...