Manual
Page 7
English STOPWATCH q The measured time is indicated by small STOPWATCH hands that move independently of STOPWATCH 1/10 second hand • After the measurement exceeds 1 minute, the STOPWATCH 1/10 second hand stays at the "0" position while the stopwatch is counting. • When the measurement is stopped or split time is being measured, it indicates the 1/10 seconds measured. 7 HOW TO READ THE HANDS q Ex. : 15 minutes and 10.6 seconds STOPWATCH 1/10 second hand STOPWATCH minute hand STOPWATCH second hand q Movement of the center hands.
English STOPWATCH q The measured time is indicated by small STOPWATCH hands that move independently of STOPWATCH 1/10 second hand • After the measurement exceeds 1 minute, the STOPWATCH 1/10 second hand stays at the "0" position while the stopwatch is counting. • When the measurement is stopped or split time is being measured, it indicates the 1/10 seconds measured. 7 HOW TO READ THE HANDS q Ex. : 15 minutes and 10.6 seconds STOPWATCH 1/10 second hand STOPWATCH minute hand STOPWATCH second hand q Movement of the center hands.
Manual
Page 14
... the time, and then push back in IC does not correspond with a new one, the information stored in the built-in to adjust the hand movement. Press repeatedly to reset STOPWATCH 1/10 second hand to "0" position.** ** The hands move improperly, follow the procedure below to normal position. 14 CROWN w Pull out...
... the time, and then push back in IC does not correspond with a new one, the information stored in the built-in to adjust the hand movement. Press repeatedly to reset STOPWATCH 1/10 second hand to "0" position.** ** The hands move improperly, follow the procedure below to normal position. 14 CROWN w Pull out...
Parts Catalog
Page 1
... on the following pages. 2 Pa. •••• reel • ' °:.. n it. 04 (). 0 z- SEIKO SR920SW, Maxell SR920SW, Sony SR920SW, Eveready 371, Matsushita SR920SW Battery life is approximately 2 years. PARTS CATALOGUE / TECHNICAL GUIDE Cal. V657A...; Electronic circuit reset switch • Demonstration movement of oil S Moebius A Moebius V 0 Oil quantity Normal quantity Cal. Reassembling procedure Figs. o • 0 e . No am Movement V657A v., Ire. Voltage: 1.65V 0 jewel SEIKO CORPORATION 1 PARTS CATALOGUE Disassembling procedure Figs. ...
... on the following pages. 2 Pa. •••• reel • ' °:.. n it. 04 (). 0 z- SEIKO SR920SW, Maxell SR920SW, Sony SR920SW, Eveready 371, Matsushita SR920SW Battery life is approximately 2 years. PARTS CATALOGUE / TECHNICAL GUIDE Cal. V657A...; Electronic circuit reset switch • Demonstration movement of oil S Moebius A Moebius V 0 Oil quantity Normal quantity Cal. Reassembling procedure Figs. o • 0 e . No am Movement V657A v., Ire. Voltage: 1.65V 0 jewel SEIKO CORPORATION 1 PARTS CATALOGUE Disassembling procedure Figs. ...
Parts Catalog
Page 2
... one. • Discrimination of cases. When repairing, refer to choose a corresponding winding stem. 26 Switch spring 4246 342 Use with the movement bearing the discrimination numeral "2". Discrimi- Height nation Numeral for date corrector (A) 58 0100 368 Main plate 0701 357 Fifth wheel and pinion it... Remarks: g Hour wheel O Fourth wheel and pinion O Center wheel and pinion Those parts specified above are determined based on the dial and movement to 10101,0 0 -TV' I •) 0012 066 Printed circuit board (B) screw 4201 288 Printed circuit board (8) 0012 066 Train wheel ...
... one. • Discrimination of cases. When repairing, refer to choose a corresponding winding stem. 26 Switch spring 4246 342 Use with the movement bearing the discrimination numeral "2". Discrimi- Height nation Numeral for date corrector (A) 58 0100 368 Main plate 0701 357 Fifth wheel and pinion it... Remarks: g Hour wheel O Fourth wheel and pinion O Center wheel and pinion Those parts specified above are determined based on the dial and movement to 10101,0 0 -TV' I •) 0012 066 Printed circuit board (B) screw 4201 288 Printed circuit board (8) 0012 066 Train wheel ...
Parts Catalog
Page 3
...Input terminal 1+) O C-MOS-LSI Crystal unit -- Press buttons "A" and "B" at the position as shown in the movement. REMARKS ON DISASSEMBLING AND REASSEMBLING Use the universal movement holder for disassembling and reassembling. 0 -) Hour, minute and second hands 0 Chronograph minute, second and 1/10 second...B 5 TECHNICAL GUIDE Cal. Follow the procedure below . TECHNICAL GUIDE Cal. VS57A • The explanation here is used, place the movements on a flat metal plate or the like, and then install the hands at the sometime for motor driving chronograph hands) -- REMARKS ...
...Input terminal 1+) O C-MOS-LSI Crystal unit -- Press buttons "A" and "B" at the position as shown in the movement. REMARKS ON DISASSEMBLING AND REASSEMBLING Use the universal movement holder for disassembling and reassembling. 0 -) Hour, minute and second hands 0 Chronograph minute, second and 1/10 second...B 5 TECHNICAL GUIDE Cal. Follow the procedure below . TECHNICAL GUIDE Cal. VS57A • The explanation here is used, place the movements on a flat metal plate or the like, and then install the hands at the sometime for motor driving chronograph hands) -- REMARKS ...