Page 5
... ATA interface 2 1.2 Native Command Queuing 2 2.0 Drive specifications 3 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 2.10 2.11 2.12 2.13 2.14 2.15 Specification summary table 3 Formatted capacity 5 2.2.1 LBA mode 5 Default logical geometry 5 Physical organization 6 Recording and interface technology 6 2.5.1 Physical characteristics 6 Seek time 7 Start/stop times 7 Power specifications 7 2.8.1 Power consumption 7 2.8.2 Deferred spinup 9 2.8.3 Conducted noise 10 2.8.4 Voltage tolerance 10 2.8.5 Power-management modes 11 Environmental specifications 11 2.9.1 Ambient temperature...
... ATA interface 2 1.2 Native Command Queuing 2 2.0 Drive specifications 3 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 2.10 2.11 2.12 2.13 2.14 2.15 Specification summary table 3 Formatted capacity 5 2.2.1 LBA mode 5 Default logical geometry 5 Physical organization 6 Recording and interface technology 6 2.5.1 Physical characteristics 6 Seek time 7 Start/stop times 7 Power specifications 7 2.8.1 Power consumption 7 2.8.2 Deferred spinup 9 2.8.3 Conducted noise 10 2.8.4 Voltage tolerance 10 2.8.5 Power-management modes 11 Environmental specifications 11 2.9.1 Ambient temperature...
Product Manual
Page 9
...-sector transfer capability without local processor intervention. • Quiet operation. • 350 Gs nonoperating shock. • SeaTools diagnostic software performs a drive self-test that eliminates unnecessary drive returns. • The 3D Defense System™, which includes Drive Defense, Data Defense and Diagnostic Defense, offers the industry's most comprehensive protection for disc drives. • Support for Read Multiple and Write Multiple commands. • Native Command Queing enabled on some models. Barracuda 7200.7 Serial ATA Product Manual...
...-sector transfer capability without local processor intervention. • Quiet operation. • 350 Gs nonoperating shock. • SeaTools diagnostic software performs a drive self-test that eliminates unnecessary drive returns. • The 3D Defense System™, which includes Drive Defense, Data Defense and Diagnostic Defense, offers the industry's most comprehensive protection for disc drives. • Support for Read Multiple and Write Multiple commands. • Native Command Queing enabled on some models. Barracuda 7200.7 Serial ATA Product Manual...
Product Manual
Page 10
... drive to the Seagate Serial ATA resource site at: www.seagate.com/products/interface/sata/. 2 Barracuda 7200.7 Serial ATA Product Manual, Rev. Note. Native Command Queuing achieves high performance and efficiency through efficient command reordering. In addition, there are three new capabilities that shadow the contents of the traditional device registers, referred to work as Microsoft Windows and Linux are represented to Serial ATA 1.0 Specification. N Serial ATA was designed to allow you to install a Serial ATA host adapter and Serial ATA disc drive...
... drive to the Seagate Serial ATA resource site at: www.seagate.com/products/interface/sata/. 2 Barracuda 7200.7 Serial ATA Product Manual, Rev. Note. Native Command Queuing achieves high performance and efficiency through efficient command reordering. In addition, there are three new capabilities that shadow the contents of the traditional device registers, referred to work as Microsoft Windows and Linux are represented to Serial ATA 1.0 Specification. N Serial ATA was designed to allow you to install a Serial ATA host adapter and Serial ATA disc drive...
Product Manual
Page 11
... section of this manual to indicate the ST3200822AS, ST3160827AS, ST3160023AS, ST3160021AS, ST3120827AS, ST3120026AS, ST3120022AS, ST380817AS, ST380013AS, ST380011AS, ST340111AS and ST340014AS models. 2.1 Specification summary table The specifications listed in BPI (bits/inch max) Track density TPI (tracks/inch max) Areal density (Gbits/inch2 max) Spindle speed (RPM) Internal transfer rate (Mbytes/sec max) Sustained transfer rate OD (Mbytes/sec) I/O data transfer rate (Mbytes/sec max) ATA data-transfer modes supported Cache buffer Height (max) Width (max) Length (max) Weight (typical...
... section of this manual to indicate the ST3200822AS, ST3160827AS, ST3160023AS, ST3160021AS, ST3120827AS, ST3120026AS, ST3120022AS, ST380817AS, ST380013AS, ST380011AS, ST340111AS and ST340014AS models. 2.1 Specification summary table The specifications listed in BPI (bits/inch max) Track density TPI (tracks/inch max) Areal density (Gbits/inch2 max) Spindle speed (RPM) Internal transfer rate (Mbytes/sec max) Sustained transfer rate OD (Mbytes/sec) I/O data transfer rate (Mbytes/sec max) ATA data-transfer modes supported Cache buffer Height (max) Width (max) Length (max) Weight (typical...
Product Manual
Page 12
... mode (typical) Standby mode (typical) Sleep mode Voltage tolerance (including noise) Ambient temperature Temperature gradient (°C per hour max) Relative humidity Relative humidity gradient Wet bulb temperature (°C max) Altitude, operating Altitude, nonoperating (meters below mean sea level, max) Shock, operating (Gs max at 2 msec) Shock, nonoperating (Gs max at 2 msec) Vibration, operating Vibration, nonoperating Drive acoustics, sound power (bels) Idle* Performance seek Nonrecoverable read errors Mean time between failures (power-on hours) Service life Warranty ST3200822AS...
... mode (typical) Standby mode (typical) Sleep mode Voltage tolerance (including noise) Ambient temperature Temperature gradient (°C per hour max) Relative humidity Relative humidity gradient Wet bulb temperature (°C max) Altitude, operating Altitude, nonoperating (meters below mean sea level, max) Shock, operating (Gs max at 2 msec) Shock, nonoperating (Gs max at 2 msec) Vibration, operating Vibration, nonoperating Drive acoustics, sound power (bels) Idle* Performance seek Nonrecoverable read errors Mean time between failures (power-on hours) Service life Warranty ST3200822AS...
Product Manual
Page 13
... SATA II specification ST3200822AS 50,000 Yes ST3160827AS ST3120827AS ST380817AS ST3160023AS ST3120026AS ST380013AS ST340111AS ST3160021AS ST3120022AS ST380011AS ST340014AS *One Gbyte equals one billion bytes when referring to hard drive capacity. See Section 4.3.1, "Identify Device command" (words 60-61 and 100-103) for additional information about 48bit addressing support of drives with capacities over 137 Gbytes. 2.3 Default logical geometry Cylinders 16,383 Read/write heads 16 Sectors per track 63 LBA mode...
... SATA II specification ST3200822AS 50,000 Yes ST3160827AS ST3120827AS ST380817AS ST3160023AS ST3120026AS ST380013AS ST340111AS ST3160021AS ST3120022AS ST380011AS ST340014AS *One Gbyte equals one billion bytes when referring to hard drive capacity. See Section 4.3.1, "Identify Device command" (words 60-61 and 100-103) for additional information about 48bit addressing support of drives with capacities over 137 Gbytes. 2.3 Default logical geometry Cylinders 16,383 Read/write heads 16 Sectors per track 63 LBA mode...
Product Manual
Page 14
...ST340014AS Read/write heads 4 3 2 1 Number of discs 2 2 1 1 2.5 Recording and interface technology Interface Recording method Recording density BPI (bits/inch max) Track density TPI (tracks/inch max) Areal density (Gbits/inch2 max) Spindle speed (RPM) (± 0.2%) Maximum Internal transfer rate (Mbytes/sec) Sustained transfer rate OD (Mbytes/sec max) I/O data-transfer rate (Mbytes/sec max) Interleave Cache buffer ST3200822AS, ST3160827AS, ST3160023AS, ST3120827AS, ST3120026AS, ST380817AS, ST380013AS and ST340111AS ST3160021AS, ST3120022AS, ST380011AS, and ST340014AS Serial ATA (SATA) 16...
...ST340014AS Read/write heads 4 3 2 1 Number of discs 2 2 1 1 2.5 Recording and interface technology Interface Recording method Recording density BPI (bits/inch max) Track density TPI (tracks/inch max) Areal density (Gbits/inch2 max) Spindle speed (RPM) (± 0.2%) Maximum Internal transfer rate (Mbytes/sec) Sustained transfer rate OD (Mbytes/sec max) I/O data-transfer rate (Mbytes/sec max) Interleave Cache buffer ST3200822AS, ST3160827AS, ST3160023AS, ST3120827AS, ST3120026AS, ST380817AS, ST380013AS and ST340111AS ST3160021AS, ST3120022AS, ST380011AS, and ST340014AS Serial ATA (SATA) 16...
Product Manual
Page 15
Table 3: Typical seek times *Typical seek times (msec) Track-to -track seek time is an average of all possible single-track seeks in the table below are defined as follows: • Track-to -track Average Average latency Read All times are taken with nominal power at least 5,000 measurements of at 25°C ambient temperature. 2.6 Seek time Seek measurements are measured using drive diagnostics. The specifications in both directions. • Average seek time is a true statistical random average of seeks between random tracks, less overhead.
Table 3: Typical seek times *Typical seek times (msec) Track-to -track seek time is an average of all possible single-track seeks in the table below are defined as follows: • Track-to -track Average Average latency Read All times are taken with nominal power at least 5,000 measurements of at 25°C ambient temperature. 2.6 Seek time Seek measurements are measured using drive diagnostics. The specifications in both directions. • Average seek time is a true statistical random average of seeks between random tracks, less overhead.
Product Manual
Page 19
... Active mode any time disc access is defined as the temperature of time. The drive accepts all commands and returns to 112°F (44°C) at 10,000 feet (3,048 meters). After receiving a reset, the drive exits Sleep mode and enters Standby mode with all commands and returns to 158°F) Barracuda 7200.7 Serial ATA Product Manual, Rev. Actual drive case temperature should not exceed 69°C (156°F) within the operating...
... Active mode any time disc access is defined as the temperature of time. The drive accepts all commands and returns to 112°F (44°C) at 10,000 feet (3,048 meters). After receiving a reset, the drive exits Sleep mode and enters Standby mode with all commands and returns to 158°F) Barracuda 7200.7 Serial ATA Product Manual, Rev. Actual drive case temperature should not exceed 69°C (156°F) within the operating...
Product Manual
Page 22
... access the follwoing web page: www.seagate.com/support/service/ From this page, click on hours (nominal power, 25°C ambient temperature) 50,000 cycles (at nominal voltage and temperature, with A 1 kHz sine EN 61000-4-6: 97 0% open, 5 seconds 0% short, 5 seconds 40%, 0.10 seconds 70%, 0.01 seconds C EN 61000-4-11: 94 C C B 2.12 Reliability Nonrecoverable read errors Mean time between failures (MTBF) Contact start-stop cycles Service...
... access the follwoing web page: www.seagate.com/support/service/ From this page, click on hours (nominal power, 25°C ambient temperature) 50,000 cycles (at nominal voltage and temperature, with A 1 kHz sine EN 61000-4-6: 97 0% open, 5 seconds 0% short, 5 seconds 40%, 0.10 seconds 70%, 0.01 seconds C EN 61000-4-11: 94 C C B 2.12 Reliability Nonrecoverable read errors Mean time between failures (MTBF) Contact start-stop cycles Service...
Product Manual
Page 25
... printed circuit board assembly (PCBA) or exposed to ensure that can be exposed to uncontrolled chemical pollutants and corrosive chemicals as vulcanized rubber, that all standard operating procedures are complied with our requirements by providing material content declarations for the disc drives documented in Seagate products are not utilized in electronic products effective July 2006. Barracuda 7200.7 Serial ATA Product Manual, Rev.
... printed circuit board assembly (PCBA) or exposed to ensure that can be exposed to uncontrolled chemical pollutants and corrosive chemicals as vulcanized rubber, that all standard operating procedures are complied with our requirements by providing material content declarations for the disc drives documented in Seagate products are not utilized in electronic products effective July 2006. Barracuda 7200.7 Serial ATA Product Manual, Rev.
Product Manual
Page 28
... host receptacle. Serial ATA drives are Device 0 (master) devices. Serial ATA connectors 3.3 Serial ATA cables and connectors The Serial ATA interface cable consists of four conductors in Figure 4. The cable size may be 30 to ensure correct orientation. 20 Barracuda 7200.7 Serial ATA Product Manual, Rev. Attaching SATA cabling Each cable is keyed to 26 AWG with a maximum length of the SATA signal cable can connect the drive as if they are designed for factory use only) SATA Power Figure 3. There is no master/slave relationship because...
... host receptacle. Serial ATA drives are Device 0 (master) devices. Serial ATA connectors 3.3 Serial ATA cables and connectors The Serial ATA interface cable consists of four conductors in Figure 4. The cable size may be 30 to ensure correct orientation. 20 Barracuda 7200.7 Serial ATA Product Manual, Rev. Attaching SATA cabling Each cable is keyed to 26 AWG with a maximum length of the SATA signal cable can connect the drive as if they are designed for factory use only) SATA Power Figure 3. There is no master/slave relationship because...
Product Manual
Page 34
... lists Serial ATA standard commands that the drive supports. N See "S.M.A.R.T. Lock: 02H Unlock: 03H Freeze Lock: 04H Set Multiple Mode C6h S.M.A.R.T. B0h Write Buffer E8h Write DMA CAh Write DMA Extended 35h 26 Barracuda 7200.7 Serial ATA Product Manual, Rev. For a detailed description of the ATA commands, refer to the right. commands" on page 33.for details and subcommands used in the Set Max Password: 01H Features register as defined to the Serial ATA: High Speed Serialized AT Attachment specification.
... lists Serial ATA standard commands that the drive supports. N See "S.M.A.R.T. Lock: 02H Unlock: 03H Freeze Lock: 04H Set Multiple Mode C6h S.M.A.R.T. B0h Write Buffer E8h Write DMA CAh Write DMA Extended 35h 26 Barracuda 7200.7 Serial ATA Product Manual, Rev. For a detailed description of the ATA commands, refer to the right. commands" on page 33.for details and subcommands used in the Set Max Password: 01H Features register as defined to the Serial ATA: High Speed Serialized AT Attachment specification.
Product Manual
Page 36
...) Drive model number: (40 ASCII characters, padded with the state of the drive. Parameters listed with an "x" are drive-specific or vary with blanks to end of data, whose contents are shown in the Serial ATA specification. See Section 2.0 on page 3 for default parameter settings. 4.3.1 Identify Device command The Identify Device command (command code ECH) transfers information about the drive to the host following commands contain drive-specific features that may be disabled ATA-reserved PIO data-transfer cycle timing mode Retired...
...) Drive model number: (40 ASCII characters, padded with the state of the drive. Parameters listed with an "x" are drive-specific or vary with blanks to end of data, whose contents are shown in the Serial ATA specification. See Section 2.0 on page 3 for default parameter settings. 4.3.1 Identify Device command The Identify Device command (command code ECH) transfers information about the drive to the host following commands contain drive-specific features that may be disabled ATA-reserved PIO data-transfer cycle timing mode Retired...
Product Manual
Page 37
... Barracuda 7200.7 Serial ATA Product Manual, Rev. This is : 0FFFFFFFh (268,435,455 sectors, 137 Gbytes). Retired Multiword DMA active and modes supported (see note following this field is required for related information) *Note: The maximum value allowed in words 100-103. Drives with IORDY flow control (120 nsec) ATA-reserved Queue depth ATA-reserved Major version number Minor version number Command sets supported Command sets supported Command sets support extension Command sets enabled Command sets enabled Command sets enable extension Ultra DMA support...
... Barracuda 7200.7 Serial ATA Product Manual, Rev. This is : 0FFFFFFFh (268,435,455 sectors, 137 Gbytes). Retired Multiword DMA active and modes supported (see note following this field is required for related information) *Note: The maximum value allowed in words 100-103. Drives with IORDY flow control (120 nsec) ATA-reserved Queue depth ATA-reserved Major version number Minor version number Command sets supported Command sets supported Command sets support extension Command sets enabled Command sets enabled Command sets enable extension Ultra DMA support...
Product Manual
Page 44
... Customer Service Operations Warranty Service Call center USA, Canada, Mexico and Latin America Brazil Jabil Industrial Do Brasil LTDA4 Toll-free 1-800-468-34723 - to 5:00 P.M., Monday through Friday (Central time). 2Hours of operation are 8:00 A.M. to 5:00 P.M., Saturday (Eastern time). 36 Barracuda 7200.7 Serial ATA Product Manual, Rev. to 8:00 P.M., Monday through Friday (Central time). 3Hours of storage media. N Data Recovery Services Seagate offers data recovery services for all formats and...
... Customer Service Operations Warranty Service Call center USA, Canada, Mexico and Latin America Brazil Jabil Industrial Do Brasil LTDA4 Toll-free 1-800-468-34723 - to 5:00 P.M., Monday through Friday (Central time). 2Hours of operation are 8:00 A.M. to 5:00 P.M., Saturday (Eastern time). 36 Barracuda 7200.7 Serial ATA Product Manual, Rev. to 8:00 P.M., Monday through Friday (Central time). 3Hours of storage media. N Data Recovery Services Seagate offers data recovery services for all formats and...
Product Manual
Page 45
...-4714 from 8:30 A.M. Barracuda 7200.7 Serial ATA Product Manual, Rev. to 11:45 A.M. to 5:00 P.M. (Central Europe time) Monday through Friday. For warranty service in Africa and the Middle East, dial our European CSO warranty center at +31-20-316-7222 from 8:00 A.M. European support services For presales and technical support in Europe, dial the Seagate Service Center toll-free number for your specific location. If your location...
...-4714 from 8:30 A.M. Barracuda 7200.7 Serial ATA Product Manual, Rev. to 11:45 A.M. to 5:00 P.M. (Central Europe time) Monday through Friday. For warranty service in Africa and the Middle East, dial our European CSO warranty center at +31-20-316-7222 from 8:00 A.M. European support services For presales and technical support in Europe, dial the Seagate Service Center toll-free number for your specific location. If your location...
Product Manual
Page 49
... latency 7 Average seek time 7 Average seek, read 4 Average seek, write 4 B bels 4 BPI 3 buffer 3, 6 Bytes per sector 3, 5 C cables and connectors 20 Cache 3, 6 capacity 5 case temperature 11 CE mark 15 certification 15 Check Power Mode 27 Class B computing device 16 compatibility 15 Conducted noise 10 Conducted RF immunity 14 Configuring the drive 19 connectors 20 Corrosive environment 17 CSA C22.2 (950) 15 current 4 cycles 14 Cylinders 5 cylinders 3 D data-transfer rates 1 DC power 7 Default logical geometry 5 Default sectors per track 3 density 3 Diagnostics 26 dimensions...
... latency 7 Average seek time 7 Average seek, read 4 Average seek, write 4 B bels 4 BPI 3 buffer 3, 6 Bytes per sector 3, 5 C cables and connectors 20 Cache 3, 6 capacity 5 case temperature 11 CE mark 15 certification 15 Check Power Mode 27 Class B computing device 16 compatibility 15 Conducted noise 10 Conducted RF immunity 14 Configuring the drive 19 connectors 20 Corrosive environment 17 CSA C22.2 (950) 15 current 4 cycles 14 Cylinders 5 cylinders 3 D data-transfer rates 1 DC power 7 Default logical geometry 5 Default sectors per track 3 density 3 Diagnostics 26 dimensions...
Product Manual
Page 50
... Equipment (ITE) 15 Initialize Device Parameters 26 Input noise ripple 10 input voltage 7 Interface 6 interface 23 Interleave 6 Internal data transfer rate 3 Internal data-transfer rate 6 ISO document 7779 13 ITE 15 K Korea Ministry of Information and Communication (MIC) 15 Korean RRL 15 L latency 4, 7 latency time 7 LBA mode 5 Length 3 logical geometry 5 M magnetoresistive (GMR) recording heads 1 maintenance 14 master/slave 2 Max Address 26 maximum temperature 11 Mean time between failures 4 Mean time between failures (MTBF) 14 measurement locations 11 MIC...
... Equipment (ITE) 15 Initialize Device Parameters 26 Input noise ripple 10 input voltage 7 Interface 6 interface 23 Interleave 6 Internal data transfer rate 3 Internal data-transfer rate 6 ISO document 7779 13 ITE 15 K Korea Ministry of Information and Communication (MIC) 15 Korean RRL 15 L latency 4, 7 latency time 7 LBA mode 5 Length 3 logical geometry 5 M magnetoresistive (GMR) recording heads 1 maintenance 14 master/slave 2 Max Address 26 maximum temperature 11 Mean time between failures 4 Mean time between failures (MTBF) 14 measurement locations 11 MIC...
Product Manual
Page 51
... 5 Sectors per track 5 sectors per track 3 Security Disable Password 27 Security Erase Prepare 27 Security Erase Unit 27 Security Freeze Lock 27 Security Set Password 27 Security Unlock 27 Seek 26 seek mode 7 Seek mode power 7 Seek power 4 Seek time 7 seek time 4 Seeking 8 Serial ATA 6 Serial ATA (SATA) interface 23 serial ATA ports 2 Servo electronics 7 servo electronics 8 Set Features 26 Set Max Address 26 Set Multiple Mode 26 Shock 12 Shock, nonoperating 4 Shock, operating 4 single-track seeks 7 Sleep 8, 11, 27 Sleep mode 4, 11 sound power 4 Specification summary table 3 Spindle speed...
... 5 Sectors per track 5 sectors per track 3 Security Disable Password 27 Security Erase Prepare 27 Security Erase Unit 27 Security Freeze Lock 27 Security Set Password 27 Security Unlock 27 Seek 26 seek mode 7 Seek mode power 7 Seek power 4 Seek time 7 seek time 4 Seeking 8 Serial ATA 6 Serial ATA (SATA) interface 23 serial ATA ports 2 Servo electronics 7 servo electronics 8 Set Features 26 Set Max Address 26 Set Multiple Mode 26 Shock 12 Shock, nonoperating 4 Shock, operating 4 single-track seeks 7 Sleep 8, 11, 27 Sleep mode 4, 11 sound power 4 Specification summary table 3 Spindle speed...