FSM726 User Manual
Page 5
... Conventions 1-1 Special Message Formats 1-1 Features of the HTML Version of this Manual 1-2 Chapter 2 Switch Management Overview Management Access Overview 1-1 Protocols ...1-2 Virtual Terminal Protocols 1-3 SNMP Protocol 1-3 SNMP Access ...1-3 Chapter 3 Software Upgrade Procedure Chapter 4 Administration Console Telnet Interface Set Up Your Switch Using Direct Console Access 3-1 Introduction to the Command Menu Interface 3-3 Main Menu> System ...3-5 Main Menu> Status...
... Conventions 1-1 Special Message Formats 1-1 Features of the HTML Version of this Manual 1-2 Chapter 2 Switch Management Overview Management Access Overview 1-1 Protocols ...1-2 Virtual Terminal Protocols 1-3 SNMP Protocol 1-3 SNMP Access ...1-3 Chapter 3 Software Upgrade Procedure Chapter 4 Administration Console Telnet Interface Set Up Your Switch Using Direct Console Access 3-1 Introduction to the Command Menu Interface 3-3 Main Menu> System ...3-5 Main Menu> Status...
FSM726 User Manual
Page 15
... protocol (Telnet), and a terminal connecting directly to the console port through a null-modem cable. Figure 2-1: Administration Console Access SNMP Protocol SNMP is the standard management protocol for Software v2.1 Virtual Terminal Protocols A virtual terminal...NETGEAR 700 Series Managed Switch before you can use an external SNMP-based application to manage your NETGEAR 700 Series Managed Switch. Terminal emulation differs from a Macintosh, a PC, or a UNIX workstation. SNMP Access With this management method. Switch Management Overview 2-3 SM-10004-02 700 Series Managed Switch...
... protocol (Telnet), and a terminal connecting directly to the console port through a null-modem cable. Figure 2-1: Administration Console Access SNMP Protocol SNMP is the standard management protocol for Software v2.1 Virtual Terminal Protocols A virtual terminal...NETGEAR 700 Series Managed Switch before you can use an external SNMP-based application to manage your NETGEAR 700 Series Managed Switch. Terminal emulation differs from a Macintosh, a PC, or a UNIX workstation. SNMP Access With this management method. Switch Management Overview 2-3 SM-10004-02 700 Series Managed Switch...
FSM726 User Manual
Page 21
...-100/ANSI menu-driven user interface for performing management activities. Figure 4-1: Administration Console Management Method Set Up Your Switch Using Direct Console Access The direct access management method is achieved by connecting the switch's console port to a VT-100 or compatible terminal or to the switch's console port. Chapter 4 Administration Console Telnet Interface The administration console is made using the null-modem cable supplied...
...-100/ANSI menu-driven user interface for performing management activities. Figure 4-1: Administration Console Management Method Set Up Your Switch Using Direct Console Access The direct access management method is achieved by connecting the switch's console port to a VT-100 or compatible terminal or to the switch's console port. Chapter 4 Administration Console Telnet Interface The administration console is made using the null-modem cable supplied...
FSM726 User Manual
Page 22
... for this menu. Figure 4-3: COM Port Selection 4-2 Administration Console Telnet Interface SM-10004-02 Select Hyper Terminal 2. Click OK. Figure 4-2: Connection Description 3. The following screen will appear. Click OK. 700 Series Managed Switch User's Guide for Software v2.1 Examples of terminal-emulation programs include: • Hyper Terminal, which the switch will appear. In the example...
... for this menu. Figure 4-3: COM Port Selection 4-2 Administration Console Telnet Interface SM-10004-02 Select Hyper Terminal 2. Click OK. Figure 4-2: Connection Description 3. The following screen will appear. Click OK. 700 Series Managed Switch User's Guide for Software v2.1 Examples of terminal-emulation programs include: • Hyper Terminal, which the switch will appear. In the example...
FSM726 User Manual
Page 51
... a standard Web browser such as if you were directly connected to the switch's console port. Figure 5-1: Web Management Method Web-Based Management Interface 5-1 SM-10004-02 Chapter 5 Web-Based Management Interface Your NETGEAR 700 Series Managed Switch provides a built-in browser interface that lets you configure and manage it 's web interface. Figure 4-1 shows this way, you can assign an IP...
... a standard Web browser such as if you were directly connected to the switch's console port. Figure 5-1: Web Management Method Web-Based Management Interface 5-1 SM-10004-02 Chapter 5 Web-Based Management Interface Your NETGEAR 700 Series Managed Switch provides a built-in browser interface that lets you configure and manage it 's web interface. Figure 4-1 shows this way, you can assign an IP...
FSM726 User Manual
Page 91
...prompt may look different if you must be using either the console port or a telnet session to a command used in this manual are listed below: • The CLI syntax is presented in bold ariel text with the 700 Series Managed switch model number followed by a "#", such as the root ...prompt. You will see a prompt similar to the CMI. Chapter 6 Command Line Interface The 700 Series Managed Switch features a Command Line Interface (CLI) designed for expert users who are enclosed in square brackets ([]), for instance, system password • The optional...
...prompt may look different if you must be using either the console port or a telnet session to a command used in this manual are listed below: • The CLI syntax is presented in bold ariel text with the 700 Series Managed switch model number followed by a "#", such as the root ...prompt. You will see a prompt similar to the CMI. Chapter 6 Command Line Interface The 700 Series Managed Switch features a Command Line Interface (CLI) designed for expert users who are enclosed in square brackets ([]), for instance, system password • The optional...
FSM726 User Manual
Page 150
... 5-10 CLI Show Trunking 5-10 CLI Show VLAN 5-11 CLI Show VLAN Brief 5-11 CLI Show VLAN COS-PVID 5-12 CMI 3-3 COM Port Selection 3-2 Command Menu Interface 3-3 Comments 3-9 Configuration Manager 4-28 console port 3-1 conventions typography 1-1 Cost 3-24, 4-35 2 crossover cable D-2 D Device Reset 4-18 Differentiated Service 3-19 Differentiated Service Code Points 3-19 DiffServ 3-19 Direct...
... 5-10 CLI Show Trunking 5-10 CLI Show VLAN 5-11 CLI Show VLAN Brief 5-11 CLI Show VLAN COS-PVID 5-12 CMI 3-3 COM Port Selection 3-2 Command Menu Interface 3-3 Comments 3-9 Configuration Manager 4-28 console port 3-1 conventions typography 1-1 Cost 3-24, 4-35 2 crossover cable D-2 D Device Reset 4-18 Differentiated Service 3-19 Differentiated Service Code Points 3-19 DiffServ 3-19 Direct...
FSM750S Reference Manual
Page 4
... ...20 Step 5: Checking the Installation...21 Step 6: Applying AC Power ...21 Step 7: Connecting to the Console Port to Manage the Switch (initial configuration 21 Step 8: Connecting Devices to the Switch ...28 Adding or Removing Switches to the stack ...28 CHAPTER 5: SWITCH MANAGEMENT OVERVIEW ...29 Management Access Overview ...29 SNMP Access...29 Protocols ...30 Software Upgrade Procedure...30 CHAPTER 6: ADMINISTRATION...
... ...20 Step 5: Checking the Installation...21 Step 6: Applying AC Power ...21 Step 7: Connecting to the Console Port to Manage the Switch (initial configuration 21 Step 8: Connecting Devices to the Switch ...28 Adding or Removing Switches to the stack ...28 CHAPTER 5: SWITCH MANAGEMENT OVERVIEW ...29 Management Access Overview ...29 SNMP Access...29 Protocols ...30 Software Upgrade Procedure...30 CHAPTER 6: ADMINISTRATION...
FSM750S Reference Manual
Page 10
... system later as the introduction for using your NETGEAR FSM726S or FSM750S Stackable Switch and provides the following information: Overview Switch Features Package contents Overview Your NETGEAR Model FSM726S or FSM750S Managed Stackable Switch provides the benefit of management with two stacking ports that have a mix of each other NETGEAR Model FSM726S or FSM750S Managed Stackable Switches. The 10/100 ports are used in a simple and intuitive manner...
... system later as the introduction for using your NETGEAR FSM726S or FSM750S Stackable Switch and provides the following information: Overview Switch Features Package contents Overview Your NETGEAR Model FSM726S or FSM750S Managed Stackable Switch provides the benefit of management with two stacking ports that have a mix of each other NETGEAR Model FSM726S or FSM750S Managed Stackable Switches. The 10/100 ports are used in a simple and intuitive manner...
FSM750S Reference Manual
Page 14
... module bay) LED descriptions Console port Stacking ports Front Panels Figures 2-1 and 2-2 show the key components on the front and back panels of the NETGEAR Model FSM726S and FSM750S Managed Stackable Switch. Figure 2-1: Front Panel of the FSM726S Managed Stackable Switch Figure 2-2: Back Panel of the FSM726S Managed Stackable Switch Figure 2-3: Front Panel of the FSM750S Managed Stackable Switch Figure 2-4: Back Panel of the FSM750S Managed Stackable Switch Page 13 of 121...
... module bay) LED descriptions Console port Stacking ports Front Panels Figures 2-1 and 2-2 show the key components on the front and back panels of the NETGEAR Model FSM726S and FSM750S Managed Stackable Switch. Figure 2-1: Front Panel of the FSM726S Managed Stackable Switch Figure 2-2: Back Panel of the FSM726S Managed Stackable Switch Figure 2-3: Front Panel of the FSM750S Managed Stackable Switch Figure 2-4: Back Panel of the FSM750S Managed Stackable Switch Page 13 of 121...
FSM750S Reference Manual
Page 16
... On Blinking Off On Off Description Power is disconnected Port has a valid link connection. No data transmission is occurring. Stack In port has a valid link connection. Console Port Your NETGEAR Model FSM726S or FSM750S Managed Stackable Switch has a console port on the switch and Gigabit Ethernet module. These ports are additional LEDs for the initial management configuration. Table 2-1. Collision is occurring on the back...
... On Blinking Off On Off Description Power is disconnected Port has a valid link connection. No data transmission is occurring. Stack In port has a valid link connection. Console Port Your NETGEAR Model FSM726S or FSM750S Managed Stackable Switch has a console port on the switch and Gigabit Ethernet module. These ports are additional LEDs for the initial management configuration. Table 2-1. Collision is occurring on the back...
FSM750S Reference Manual
Page 20
...the console port to manage the switch (initial configuration) Step 8: Connecting devices to the switch This chapter also discusses how to add or remove switches to stack two or more switches, be...switch, be sure your NETGEAR Model FSM726S or FSM750S Managed Stackable Switch. Access Power source Environmental Temperature: Operating humidity: Ventilation: Operating conditions: Stacking Locate the switch in Appendix C. Be sure there is not controlled by covering or obstructing air inlets on a Flat Surface The switch ships with your NETGEAR Model FSM726S or FSM750S Managed Stackable Switch...
...the console port to manage the switch (initial configuration) Step 8: Connecting devices to the switch This chapter also discusses how to add or remove switches to stack two or more switches, be...switch, be sure your NETGEAR Model FSM726S or FSM750S Managed Stackable Switch. Access Power source Environmental Temperature: Operating humidity: Ventilation: Operating conditions: Stacking Locate the switch in Appendix C. Be sure there is not controlled by covering or obstructing air inlets on a Flat Surface The switch ships with your NETGEAR Model FSM726S or FSM750S Managed Stackable Switch...
FSM750S Reference Manual
Page 22
... bent pins, do not have the Stack In port empty. Use extra care to Appendix B, Troubleshooting. Step 7: Connecting to the Console Port to Manage the Switch (initial configuration) Your NETGEAR Model FSM726S or FSM750S Managed Stackable Switch contains software for the switch to the switch. You can turn off power to work. Note: The switch that the power source is not required for...
... bent pins, do not have the Stack In port empty. Use extra care to Appendix B, Troubleshooting. Step 7: Connecting to the Console Port to Manage the Switch (initial configuration) Your NETGEAR Model FSM726S or FSM750S Managed Stackable Switch contains software for the switch to the switch. You can turn off power to work. Note: The switch that the power source is not required for...
FSM750S Reference Manual
Page 23
... browser, Telnet session, or SNMP management application. This example shows screenshots of your switches, you only have assigned an IP address to the switch's console port, labeled Console, using the console, see Chapter 6, Administration Console Access. The supplied null-modem cable...FSM750S. Once you are stacking your network. UNIX users can use HyperTerminal, which comes with the switch. modem cable supplied with the Windows operating systems. Macintosh users can assign an IP address, subnet mask, and gateway address to configure the Master unit via the Console port...
... browser, Telnet session, or SNMP management application. This example shows screenshots of your switches, you only have assigned an IP address to the switch's console port, labeled Console, using the console, see Chapter 6, Administration Console Access. The supplied null-modem cable...FSM750S. Once you are stacking your network. UNIX users can use HyperTerminal, which comes with the switch. modem cable supplied with the Windows operating systems. Macintosh users can assign an IP address, subnet mask, and gateway address to configure the Master unit via the Console port...
FSM750S Reference Manual
Page 31
... the User Datagram Protocol (UDP), offering a connectionless-mode service. Figure 5-1: SNMP-Based Management Method Protocols Your NETGEAR Model FSM726S or FSM750S Managed Stackable Switch supports the following section. Software Upgrade Procedure The application software is set the 'Next Boot From' configuration parameter to the console port. The upgrade procedure and the required equipment are described in the System...
... the User Datagram Protocol (UDP), offering a connectionless-mode service. Figure 5-1: SNMP-Based Management Method Protocols Your NETGEAR Model FSM726S or FSM750S Managed Stackable Switch supports the following section. Software Upgrade Procedure The application software is set the 'Next Boot From' configuration parameter to the console port. The upgrade procedure and the required equipment are described in the System...
FSM750S Reference Manual
Page 34
... Web management access method (described in chapter 7) to a PC, Apple Macintosh, or UNIX workstation equipped with the switch. Note: All screen shots for the FSM750S are very similar. This connection is made using VT100 terminal emulation, can view the administration console from a terminal, PC, Apple Macintosh, or UNIX workstation connected to the switch's console port. The console, using...
... Web management access method (described in chapter 7) to a PC, Apple Macintosh, or UNIX workstation equipped with the switch. Note: All screen shots for the FSM750S are very similar. This connection is made using VT100 terminal emulation, can view the administration console from a terminal, PC, Apple Macintosh, or UNIX workstation connected to the switch's console port. The console, using...
FSM750S Reference Manual
Page 65
Add host o Enter the host name, IP address, and the community string. o Press Ctrl-W to the switch. Figure 6-29: SNMP Management: Host Table Page 64 of 121 Main Menu> Advanced Menu> SNMP> Host Table The screen, shown in Figure 6-29, grants a host the access rights to ... next field. Press Enter after each entry to move to use the host table. If Host Authorization is enabled, the host must be access the switch via SNMP. Host Authorization must be added to this table, through the Console port connection in the host table from accessing the...
Add host o Enter the host name, IP address, and the community string. o Press Ctrl-W to the switch. Figure 6-29: SNMP Management: Host Table Page 64 of 121 Main Menu> Advanced Menu> SNMP> Host Table The screen, shown in Figure 6-29, grants a host the access rights to ... next field. Press Enter after each entry to move to use the host table. If Host Authorization is enabled, the host must be access the switch via SNMP. Host Authorization must be added to this table, through the Console port connection in the host table from accessing the...
FSM750S Reference Manual
Page 68
... can assign an IP address and subnet mask to the switch's console port. Netscape Navigator), a login screen will cover many of the basic functions and features of the switch and it remotely using the console) without setting your own password, the default password is ... 'help' page will appear prompting for system monitoring of 121 Page 67 of the Switch. Enter the password to the switch via a web browser (i.e. CHAPTER 7: WEB MANAGEMENT ACCESS Your NETGEAR Model FSM726S or FSM750S Managed Stackable Switch provides a built-in browser interface that lets you configure and...
... can assign an IP address and subnet mask to the switch's console port. Netscape Navigator), a login screen will cover many of the basic functions and features of the switch and it remotely using the console) without setting your own password, the default password is ... 'help' page will appear prompting for system monitoring of 121 Page 67 of the Switch. Enter the password to the switch via a web browser (i.e. CHAPTER 7: WEB MANAGEMENT ACCESS Your NETGEAR Model FSM726S or FSM750S Managed Stackable Switch provides a built-in browser interface that lets you configure and...
FSM750S Reference Manual
Page 100
... 7-30: SNMP Management > Host Table Page 99 of 121 Advanced> SNMP> Host Table The SNMP Host Table screen allows you to add and remove hosts from access rights that have been granted to the appropriate community string. Host Authorization can be access the switch via SNMP. The... permissions GET, SET and TRAP are assigned to a community name and then these permissions are assigned to individual machines by adding those machines and their IP address to community groups. If Host Authorization is enabled, the host must be added to this table, through the Console port...
... 7-30: SNMP Management > Host Table Page 99 of 121 Advanced> SNMP> Host Table The SNMP Host Table screen allows you to add and remove hosts from access rights that have been granted to the appropriate community string. Host Authorization can be access the switch via SNMP. The... permissions GET, SET and TRAP are assigned to a community name and then these permissions are assigned to individual machines by adding those machines and their IP address to community groups. If Host Authorization is enabled, the host must be added to this table, through the Console port...
FSM750S Reference Manual
Page 116
...Interface 26 (FSM726S) or 50 (FSM750S) RJ-45 connectors for 10BASE-T, 100BASE-TX, and 1000BASE-T (Auto Uplink™ on all ports) 2 Gigabit Interface Converter (GBIC) slots for GBIC modules RS-232 Console Port 2 Rear Stacking Connectors LEDs Per port (10/100 and Gigabit): Link... memory for 24 ports 735 KB embedded memory for the NETGEAR Model and FSM750S Managed Stackable Switch. APPENDIX D: TECHNICAL SPECIFICATIONS This appendix provides technical specifications for 24 ports Gigabit buffer memory: 122 KB embedded memory per port 122 KB embedded memory per port Address database size:...
...Interface 26 (FSM726S) or 50 (FSM750S) RJ-45 connectors for 10BASE-T, 100BASE-TX, and 1000BASE-T (Auto Uplink™ on all ports) 2 Gigabit Interface Converter (GBIC) slots for GBIC modules RS-232 Console Port 2 Rear Stacking Connectors LEDs Per port (10/100 and Gigabit): Link... memory for 24 ports 735 KB embedded memory for the NETGEAR Model and FSM750S Managed Stackable Switch. APPENDIX D: TECHNICAL SPECIFICATIONS This appendix provides technical specifications for 24 ports Gigabit buffer memory: 122 KB embedded memory per port 122 KB embedded memory per port Address database size:...