EN104TP Installation Guide
Page 2
... offices, and lowdensity workgroups of the NETGEAR™ Model EN104TP, Model EN106TP, or Model EN108TP Ethernet hub. In this installation guide, all three hubs are referred to collectively as the Model EN104TP/EN106TP/EN108TP hub. Features The Model EN104TP/EN106TP/EN108TP hub has the following features: • Four (on the Model EN104TP hub), six (on the Model EN106TP hub), and eight (on your purchase of...
... offices, and lowdensity workgroups of the NETGEAR™ Model EN104TP, Model EN106TP, or Model EN108TP Ethernet hub. In this installation guide, all three hubs are referred to collectively as the Model EN104TP/EN106TP/EN108TP hub. Features The Model EN104TP/EN106TP/EN108TP hub has the following features: • Four (on the Model EN104TP hub), six (on the Model EN106TP hub), and eight (on your purchase of...
EN104TP Installation Guide
Page 4
... Built-in LEDs The front panel of the Model EN104TP hub has four RJ-45 10BASE-T ports, the Model EN106TP hub has six RJ-45 10BASE-T ports, and the Model EN108TP hub has eight RJ-45 10BASE-T ports. Link Rx LED LED 8724EA Model EN104TP/EN106TP/EN108TP Ethernet Hub Installation Guide Two LEDs-the Link LED and the Rx LED-are...
... Built-in LEDs The front panel of the Model EN104TP hub has four RJ-45 10BASE-T ports, the Model EN106TP hub has six RJ-45 10BASE-T ports, and the Model EN108TP hub has eight RJ-45 10BASE-T ports. Link Rx LED LED 8724EA Model EN104TP/EN106TP/EN108TP Ethernet Hub Installation Guide Two LEDs-the Link LED and the Rx LED-are...
EN104TP Installation Guide
Page 5
... 5Vdc 800mA -+ 8730FA Model EN104TP/EN106TP/EN108TP Ethernet Hub Installation Guide There is good. The link between this port and the connected device is incoming data on the top right corner of the LEDs. This uplink configuration eliminates the need to a hub or a switch through port 4 on the Model EN104TP hub, port 6 on the Model EN106TP hub, or port 8 on the network...
... 5Vdc 800mA -+ 8730FA Model EN104TP/EN106TP/EN108TP Ethernet Hub Installation Guide There is good. The link between this port and the connected device is incoming data on the top right corner of the LEDs. This uplink configuration eliminates the need to a hub or a switch through port 4 on the Model EN104TP hub, port 6 on the Model EN106TP hub, or port 8 on the network...
EN104TP Installation Guide
Page 7
... or any of the RJ-45 ports on the Model EN108TP hub, set the Normal/Uplink push button to Normal. (The Model EN106TP hub is shown in the illustration.) Pwr Col 1 2 3 4 5 Normal/Uplink 6 8726FA Note: Ethernet specifications limit the cable length between your hub to 328 feet (100 meters) .... To connect any device equipped with a 10BASE-T Ethernet interface to the RJ-45 ports on your hub by using port 4 on the Model EN104TP hub, port 6 on the Model EN106TP hub, or port 8 on your PC or server and the hub to a PC, use a regular straight-through UTP cable. If you are connecting using...
... or any of the RJ-45 ports on the Model EN108TP hub, set the Normal/Uplink push button to Normal. (The Model EN106TP hub is shown in the illustration.) Pwr Col 1 2 3 4 5 Normal/Uplink 6 8726FA Note: Ethernet specifications limit the cable length between your hub to 328 feet (100 meters) .... To connect any device equipped with a 10BASE-T Ethernet interface to the RJ-45 ports on your hub by using port 4 on the Model EN104TP hub, port 6 on the Model EN106TP hub, or port 8 on your PC or server and the hub to a PC, use a regular straight-through UTP cable. If you are connecting using...
EN104TP Installation Guide
Page 8
... Hub Model EN104TP hub: Ports 1-3 Ports 1-3 Model EN106TP hub: Ports 1-5 Ports 1-5 Model EN108TP hub: Ports 1-7 Ports 1-7 Connecting Device PC, server, or router Hub or switch PC, server, or router Hub or switch PC, server, or router Hub or switch Cable Used Straight-through cable Crossover cable Straight-through cable Crossover cable Straight-through cable Model EN104TP/EN106TP/EN108TP Ethernet Hub Installation Guide Connecting Port Port 4, port 6, or port 8 set to Normal Port 4, port 6, or port...
... Hub Model EN104TP hub: Ports 1-3 Ports 1-3 Model EN106TP hub: Ports 1-5 Ports 1-5 Model EN108TP hub: Ports 1-7 Ports 1-7 Connecting Device PC, server, or router Hub or switch PC, server, or router Hub or switch PC, server, or router Hub or switch Cable Used Straight-through cable Crossover cable Straight-through cable Crossover cable Straight-through cable Model EN104TP/EN106TP/EN108TP Ethernet Hub Installation Guide Connecting Port Port 4, port 6, or port 8 set to Normal Port 4, port 6, or port...
EN104TP Installation Guide
Page 9
... hub Model EN106TP hub 10 BASE-T HUB EN108TP Pwr Col 1 2 3 4 5 6 7 8 Uplink 10 BASE-T HUB EN106TP Pwr Col Link/Rx Partition Normal/Uplink 1 2 3 4 5 6 Uplink Model EN104TP hubs Uplink Uplink A B 8727FA Note: Ethernet specifications limit the number of hubs with PC "B," the communication path goes from hub 4 to hub 2, to hub 1, to hub 3, and then to five, as shown in a hierarchical star through the 10BASE-T ports...
... hub Model EN106TP hub 10 BASE-T HUB EN108TP Pwr Col 1 2 3 4 5 6 7 8 Uplink 10 BASE-T HUB EN106TP Pwr Col Link/Rx Partition Normal/Uplink 1 2 3 4 5 6 Uplink Model EN104TP hubs Uplink Uplink A B 8727FA Note: Ethernet specifications limit the number of hubs with PC "B," the communication path goes from hub 4 to hub 2, to hub 1, to hub 3, and then to five, as shown in a hierarchical star through the 10BASE-T ports...
EN104TP Installation Guide
Page 11
Verify the Installation To complete the installation, connect the power cord first to the power receptacle on the hub rear panel and then to the power outlet on . If there are any problems, refer to the hub: • The green Pwr (Power) LED on the front panel is on. • The green Link LED on each connected port is on the wall. Model EN104TP/EN106TP/EN108TP Ethernet Hub Installation Guide When power has been applied to "Troubleshooting Information."
Verify the Installation To complete the installation, connect the power cord first to the power receptacle on the hub rear panel and then to the power outlet on . If there are any problems, refer to the hub: • The green Pwr (Power) LED on the front panel is on. • The green Link LED on each connected port is on the wall. Model EN104TP/EN106TP/EN108TP Ethernet Hub Installation Guide When power has been applied to "Troubleshooting Information."
EN104TP Installation Guide
Page 12
...NETGEAR Ethernet switch or to upgrade your network to the switch off The port is not when there is off and then back on the network. For the phone number of the representative in place of the hub by resetting it. No action is normal on Ethernet on the connected device. Model EN104TP/EN106TP.../EN108TP Ethernet Hub Installation Guide The port is attached. Hub Integrity If required, verify the integrity of UTP cables...
...NETGEAR Ethernet switch or to upgrade your network to the switch off The port is not when there is off and then back on the network. For the phone number of the representative in place of the hub by resetting it. No action is normal on Ethernet on the connected device. Model EN104TP/EN106TP.../EN108TP Ethernet Hub Installation Guide The port is attached. Hub Integrity If required, verify the integrity of UTP cables...
EN104TP Installation Guide
Page 13
...in the device. The figures illustrate the use of the other device. Most ports on switches and repeaters have media-dependent interfaces with crossover ports. Uplink or MDI port 1 Tx 2 Straight-through and crossover twisted pair cables. CTaebclhenaicnadl CSopnenciefcictaotrioInnfsormation Twisted ... connected to the receiver of straight-through twisted pair cable Normal or MDI-X port 1 Rx 2 3 Rx 6 3 Tx 6 Normal or MDI-X port 1 Rx 2 Crossover twisted pair cable Normal or MDI-X port 1 Rx 2 3 Tx 6 3 Tx 6 8146EA Model EN104TP/EN106TP/EN108TP Ethernet Hub Installation Guide
...in the device. The figures illustrate the use of the other device. Most ports on switches and repeaters have media-dependent interfaces with crossover ports. Uplink or MDI port 1 Tx 2 Straight-through and crossover twisted pair cables. CTaebclhenaicnadl CSopnenciefcictaotrioInnfsormation Twisted ... connected to the receiver of straight-through twisted pair cable Normal or MDI-X port 1 Rx 2 3 Rx 6 3 Tx 6 Normal or MDI-X port 1 Rx 2 Crossover twisted pair cable Normal or MDI-X port 1 Rx 2 3 Tx 6 3 Tx 6 8146EA Model EN104TP/EN106TP/EN108TP Ethernet Hub Installation Guide
EN104TP Installation Guide
Page 14
...-45 Connector Pin Assignment Normal Assignment: Ports 1-3 on the Model EN104TP hub Ports 1-5 on the Model EN106TP hub Ports 1-7 on the Model EN108TP hub 1 Input Receive Data + 2 Input Receive Data - 3 Output Transmit Data + 6 Output Transmit Data - 4, 5, 7, 8 Not used 81 711EA Uplink Assignment: Port 4 on the Model EN104TP hub Port 6 on the Model EN106TP hub Port 8 on the Model EN108TP hub Output Transmit Data + Output Transmit Data...
...-45 Connector Pin Assignment Normal Assignment: Ports 1-3 on the Model EN104TP hub Ports 1-5 on the Model EN106TP hub Ports 1-7 on the Model EN108TP hub 1 Input Receive Data + 2 Input Receive Data - 3 Output Transmit Data + 6 Output Transmit Data - 4, 5, 7, 8 Not used 81 711EA Uplink Assignment: Port 4 on the Model EN104TP hub Port 6 on the Model EN106TP hub Port 8 on the Model EN108TP hub Output Transmit Data + Output Transmit Data...
EN104TP Installation Guide
Page 15
... IEEE 802.3i, 10BASE-T Ethernet Data Rate 10 Mbps, Manchester encoded Interface 4 10BASE-T ports (RJ-45) on the Model EN104TP hub 6 10BASE-T ports (RJ-45) on the Model EN106TP hub 8 10BASE-T ports (RJ-45) on the Model EN108TP hub Power Power Consumption: Model EN104TP hub Model EN106TP hub Model EN108TP hub 3.5 W 7.2 W 13.7 W DC output voltage (Power adapter): Model EN104TP hub 5V DC @ 800 mA max.
... IEEE 802.3i, 10BASE-T Ethernet Data Rate 10 Mbps, Manchester encoded Interface 4 10BASE-T ports (RJ-45) on the Model EN104TP hub 6 10BASE-T ports (RJ-45) on the Model EN106TP hub 8 10BASE-T ports (RJ-45) on the Model EN108TP hub Power Power Consumption: Model EN104TP hub Model EN106TP hub Model EN108TP hub 3.5 W 7.2 W 13.7 W DC output voltage (Power adapter): Model EN104TP hub 5V DC @ 800 mA max.