WMK3260-L accessory brochure
Page 1
... looking to change. 5/09 ver. 2. ©2009 NEC Display Solutions of America, Inc. Model NEC Displays Supported* NEC MultiSync® 20 Series 40" LCD4020 46" LCD4620 52" LCD5220 57" LCD5710 NEC MultiSync 15 Series 32" LCD3215 42" LCD4215 46" LCD4615 Dimensions Net Gross Weight Net Gross Warranty NEC MultiSync X Series 46" X461UN 46" X461HB NEC M Series 40" M40B 46" M46B * in...
... looking to change. 5/09 ver. 2. ©2009 NEC Display Solutions of America, Inc. Model NEC Displays Supported* NEC MultiSync® 20 Series 40" LCD4020 46" LCD4620 52" LCD5220 57" LCD5710 NEC MultiSync 15 Series 32" LCD3215 42" LCD4215 46" LCD4615 Dimensions Net Gross Weight Net Gross Warranty NEC MultiSync X Series 46" X461UN 46" X461HB NEC M Series 40" M40B 46" M46B * in...
MultiSync LCD4020/4620/5220 brochure
Page 1
...52" LCD5220, provides a firstclass solution for your messaging options with superior screen performance. The Administrator version utilizes the monitor's advanced control and diagnostics capabilities to source devices ¤ NaViSet™ software offers an expanded and intuitive graphical interface, allowing for easy adjustment of display settings via mouse and keyboard. Large-Screen LCD NEC MultiSync... protection starts with TileMatrix to recalibrate the display. ¤ LCD4020-2-AVT, LCD4620-2-AVT and LCD5220-AVT feature a built-in tuner for advanced scheduling of -the art ...
...52" LCD5220, provides a firstclass solution for your messaging options with superior screen performance. The Administrator version utilizes the monitor's advanced control and diagnostics capabilities to source devices ¤ NaViSet™ software offers an expanded and intuitive graphical interface, allowing for easy adjustment of display settings via mouse and keyboard. Large-Screen LCD NEC MultiSync... protection starts with TileMatrix to recalibrate the display. ¤ LCD4020-2-AVT, LCD4620-2-AVT and LCD5220-AVT feature a built-in tuner for advanced scheduling of -the art ...
MultiSync LCD4020/4620/5220 brochure
Page 2
...in. / 886.5 x 497.8mm LCD4620 46" SPVA 0.746mm 500 cd/m2 2000:1 40.1 x 22.6 in. / 1018.5 x 574mm LCD5220 52" 1920 x 1080 0.60mm 45.4 x 25.5 in. / 1152 x 648mm LCD4020-2-AVT DVI-D Analog D-sub 5 BNC (RGBHV) Composite (Shared RCA and BNC) S-Video HDMI Component BNC Audio 1 (MiniJack), Audio 2 and ...3 Stereo (RCA), HDMI / Internal Speaker: None RS-232, DDC/CI Yes Yes Yes RS-232 for LCD4020/LCD4620/LCD5220 MODE L LCD MODULE Viewable Size ...
...in. / 886.5 x 497.8mm LCD4620 46" SPVA 0.746mm 500 cd/m2 2000:1 40.1 x 22.6 in. / 1018.5 x 574mm LCD5220 52" 1920 x 1080 0.60mm 45.4 x 25.5 in. / 1152 x 648mm LCD4020-2-AVT DVI-D Analog D-sub 5 BNC (RGBHV) Composite (Shared RCA and BNC) S-Video HDMI Component BNC Audio 1 (MiniJack), Audio 2 and ...3 Stereo (RCA), HDMI / Internal Speaker: None RS-232, DDC/CI Yes Yes Yes RS-232 for LCD4020/LCD4620/LCD5220 MODE L LCD MODULE Viewable Size ...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 1
... 1. Connectors and wiring Connector: D-Sub 9-pin Cable: Cross (reversed) cable or null modem cable (Please refer "Using the LCD with RS-232C" on each User's manual.) 3. Application This document defines the communications method for control of the NEC LCD monitor, MultiSync LCD4020/4620/5220/6520 and MULTEOS M40/46 when using an external controller. 2.
... 1. Connectors and wiring Connector: D-Sub 9-pin Cable: Cross (reversed) cable or null modem cable (Please refer "Using the LCD with RS-232C" on each User's manual.) 3. Application This document defines the communications method for control of the NEC LCD monitor, MultiSync LCD4020/4620/5220/6520 and MULTEOS M40/46 when using an external controller. 2.
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 2
Sequence of four parts, Header, Message, Check code and Delimiter. The monitor replies to the controller for confirmation. The monitor replies an adjusted value. set an adjusted value. The controller requests to store the adjusted value to change. On this monitor, it must match the "Monitor ID No." This value must be ASCII '0'(30h). 3rdbyte) Destination: Destination equipment ID. (Receiver) Specify a commands receiver's address. The monitor replies a current value of Header ASCII SOH (01h) 2ndbyte) Reserved: Reserved for future extensions. The controller sends command to ...
Sequence of four parts, Header, Message, Check code and Delimiter. The monitor replies to the controller for confirmation. The monitor replies an adjusted value. set an adjusted value. The controller requests to store the adjusted value to change. On this monitor, it must match the "Monitor ID No." This value must be ASCII '0'(30h). 3rdbyte) Destination: Destination equipment ID. (Receiver) Specify a commands receiver's address. The monitor replies a current value of Header ASCII SOH (01h) 2ndbyte) Reserved: Reserved for future extensions. The controller sends command to ...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 3
If you want to control all of the message (that has the "ID No." The controller must be encoded to ASCII characters '3' and 'A' (33h and 41h). ASCII 'D' (44h): "Get parameter" reply. The byte data must be encoded to ASCII characters '0' and 'B' (30h and 42h). 4.2 Message block format Header Message Check code Delimiter "Message block format" is as '1', specify a destination address 'A'(41h). Refer to the section 6 "Message format" for more detail. (3/40) ASCII 'B' (42h): Command reply. ASCII 'C' (43h): Get current parameter from STX to ETX. as follows, Monitor ID 1 2 3...
If you want to control all of the message (that has the "ID No." The controller must be encoded to ASCII characters '3' and 'A' (33h and 41h). ASCII 'D' (44h): "Get parameter" reply. The byte data must be encoded to ASCII characters '0' and 'B' (30h and 42h). 4.2 Message block format Header Message Check code Delimiter "Message block format" is as '1', specify a destination address 'A'(41h). Refer to the section 6 "Message format" for more detail. (3/40) ASCII 'B' (42h): Command reply. ASCII 'C' (43h): Get current parameter from STX to ETX. as follows, Monitor ID 1 2 3...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 4
"Message format" of the "Get parameter reply" is as follows, Result OP code OP code Type STX page Max value Current Value ETX Hi Lo Hi Lo Hi Lo Hi Lo MSB LSB MSB LSB Refer to change a setting of the "Set parameter message". Message format of the "Set parameter" is as follows, STX OP code page OP code Set Value ETX Hi Lo Hi Lo MSB LSB Refer to section 5.3 "Set parameter" for more details. 2 Get Parameter reply The monitor will reply with this message to section 5.2 "Get parameter reply" for more details. 3 Set parameter The controller ...
"Message format" of the "Get parameter reply" is as follows, Result OP code OP code Type STX page Max value Current Value ETX Hi Lo Hi Lo Hi Lo Hi Lo MSB LSB MSB LSB Refer to change a setting of the "Set parameter message". Message format of the "Set parameter" is as follows, STX OP code page OP code Set Value ETX Hi Lo Hi Lo MSB LSB Refer to section 5.3 "Set parameter" for more details. 2 Get Parameter reply The monitor will reply with this message to section 5.2 "Get parameter reply" for more details. 3 Set parameter The controller ...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 5
Delimiter (5/40) "Command reply message" format depends on each command. SOH Reserved Destination Source Type Length STX Data | | ETX Check code 27 26 25 24 23 22 21 20 D0 D1 D2 D3 D4 D5 D6 D7 | | Dn Dn+1 P P P P P P P P Dn+1 = D1 XOR D2 XOR D3 XOR ,,, Dn XOR: Exclusive OR Following is the Block Check Code (BCC) between the Header and the End of a Check code (BCC) calculation. ASCII CR(0Dh). xor D14 xor D15 xor D16 = 30h xor 41h xor 30h xor 45h xor 30h xor 41h xor 02h xor 30h xor 30h xor 31h xor 30h xor 30h xor 30h xor 36h xor 34h xor 03h = 77h 4.6 ...
Delimiter (5/40) "Command reply message" format depends on each command. SOH Reserved Destination Source Type Length STX Data | | ETX Check code 27 26 25 24 23 22 21 20 D0 D1 D2 D3 D4 D5 D6 D7 | | Dn Dn+1 P P P P P P P P Dn+1 = D1 XOR D2 XOR D3 XOR ,,, Dn XOR: Exclusive OR Following is the Block Check Code (BCC) between the Header and the End of a Check code (BCC) calculation. ASCII CR(0Dh). xor D14 xor D15 xor D16 = 30h xor 41h xor 30h xor 45h xor 30h xor 41h xor 02h xor 30h xor 30h xor 31h xor 30h xor 30h xor 30h xor 36h xor 34h xor 03h = 77h 4.6 ...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 6
OP code page 02h -> OP code page (Hi) = ASCII '0' (30h) OP code page (Lo) = ASCII '2' (32h) Refer to Operation code table. (Appendix A) 4th-5thbytes) OP code: Operation code Refer to ASCII characters. OP code data must be encoded to ASCII characters '0' and '2' (30h and 32h). For the status that you want to "Appendix A Operation code table" for each item. Operation code table". 1stbyte) STX: Start of Message ASCII STX (02h) 2nd-3rdbytes) Result code. (6/40) Refer to get the status. OP code 3Ah -> OP code (Hi) = ASCII '3' (33h) OP code (Lo) = ASCII 'A' (41h) Refer ...
OP code page 02h -> OP code page (Hi) = ASCII '0' (30h) OP code page (Lo) = ASCII '2' (32h) Refer to Operation code table. (Appendix A) 4th-5thbytes) OP code: Operation code Refer to ASCII characters. OP code data must be encoded to ASCII characters '0' and '2' (30h and 32h). For the status that you want to "Appendix A Operation code table" for each item. Operation code table". 1stbyte) STX: Start of Message ASCII STX (02h) 2nd-3rdbytes) Result code. (6/40) Refer to get the status. OP code 3Ah -> OP code (Hi) = ASCII '3' (33h) OP code (Lo) = ASCII 'A' (41h) Refer ...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 7
This returned value from the monitor is encoded to the operation code table. Refer to ASCII character '1' and 'A' (31h and 41h). 8th -9thbytes) Type: Operation type code 00h: Set parameter 01h: Momentary Like the Auto Setup function which monitor can accept. (16bits) This returned value from the monitor is encoded to ASCII characters. Ex.) The byte data 1Ah is encoded to ASCII characters. This returned value from the monitor is encoded to ASCII character '0' and '2' (30h and 32h). The controller requests a monitor to ASCII characters. Ex.) The byte data 01h is...
This returned value from the monitor is encoded to the operation code table. Refer to ASCII character '1' and 'A' (31h and 41h). 8th -9thbytes) Type: Operation type code 00h: Set parameter 01h: Momentary Like the Auto Setup function which monitor can accept. (16bits) This returned value from the monitor is encoded to ASCII characters. Ex.) The byte data 1Ah is encoded to ASCII characters. This returned value from the monitor is encoded to ASCII character '0' and '2' (30h and 32h). The controller requests a monitor to ASCII characters. Ex.) The byte data 01h is...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 8
Reply data from the monitor is encoded to ASCII characters. Reply data from the monitor is encoded to ASCII characters. Refer to the Operation code table. 4th-5thbytes) OP code: Operation code This OP code data must be encoded to ASCII '0' and '2' (30h and 32h). ASCII '0''1' (30h, 31h): Unsupported operation with this monitor or unsupported operation under current condition. 4th-5thbytes) OP code page: Echoes back the Operation code page for confirmation. Ex.) OP code page 02h -> OP code page = ASCII '0' and '2' (30h and 32h) Refer to Operation code table. 6th-7thbytes) OP code...
Reply data from the monitor is encoded to ASCII characters. Reply data from the monitor is encoded to ASCII characters. Refer to the Operation code table. 4th-5thbytes) OP code: Operation code This OP code data must be encoded to ASCII '0' and '2' (30h and 32h). ASCII '0''1' (30h, 31h): Unsupported operation with this monitor or unsupported operation under current condition. 4th-5thbytes) OP code page: Echoes back the Operation code page for confirmation. Ex.) OP code page 02h -> OP code page = ASCII '0' and '2' (30h and 32h) Refer to Operation code table. 6th-7thbytes) OP code...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 9
The controller requests for confirmation. (16bits) Reply data from the monitor is out of Message ASCII ETX (03h) 5.5 Commands "Command message format" depends on each command. ETX LSB (9/40) Ex.) '0''1''2''3' means 0123h (291) 14th -17thbytes) Requested setting Value: Echoes back the parameter for the monitor to store the adjusted value. CR The monitor replies status as follows; Some commands are shown with usage. Command code STX ETX '0' '7' Send "07"(30h, 37h) as Get Timing Report command. Complete "Get Timing Report" command packet as...
The controller requests for confirmation. (16bits) Reply data from the monitor is out of Message ASCII ETX (03h) 5.5 Commands "Command message format" depends on each command. ETX LSB (9/40) Ex.) '0''1''2''3' means 0123h (291) 14th -17thbytes) Requested setting Value: Echoes back the parameter for the monitor to store the adjusted value. CR The monitor replies status as follows; Some commands are shown with usage. Command code STX ETX '0' '7' Send "07"(30h, 37h) as Get Timing Report command. Complete "Get Timing Report" command packet as...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 10
Bit 5-2 Reserved (Don't care) Bit 1 1:Positive Horizontal sync polarity. 0:Negative Horizontal sync polarity. Bit 0 1:Positive Vertical sync polarity. 0:Negative Vertical sync polarity. H Freq: Horizontal Frequency in unit 0.01kHz V Freq: Vertical Frequency in unit 0.01Hz Ex.) When H Freq is '1''2''A''9' (31h, 32h, 41h, 39h), it means 47.77kHz. 5.5.3 NULL Message Command code STX ETX 'B' 'E' The NULL message returned from which you want to change the "Brightness" setting. How to get a value. The controller requests the Monitor to reply with the current ...
Bit 5-2 Reserved (Don't care) Bit 1 1:Positive Horizontal sync polarity. 0:Negative Horizontal sync polarity. Bit 0 1:Positive Vertical sync polarity. 0:Negative Vertical sync polarity. H Freq: Horizontal Frequency in unit 0.01kHz V Freq: Vertical Frequency in unit 0.01Hz Ex.) When H Freq is '1''2''A''9' (31h, 32h, 41h, 39h), it means 47.77kHz. 5.5.3 NULL Message Command code STX ETX 'B' 'E' The NULL message returned from which you want to change the "Brightness" setting. How to get a value. The controller requests the Monitor to reply with the current ...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 11
Ex.) When this operation. Message STX (02h): Start of which you want to 'A', the replying Monitor ID is '1'. 'D' (44h): Message Type is "Get parameter reply". '1'-'2' (31h, 32h): Message length is the controller. Header SOH-'0'-'0'-Monitor ID-'D'-'1'-'2' Message STX-'0'-'0'-'0'-'0'-'1'-'0'-'0'-'0' -'0'-'0'-'6'-'4'-'0'-'0'-'3'-'2'-ETX Check code BCC Delimiter CR Header SOH (01h): Start Of Header '0' (30h): Reserved '0' (30h): Message receiver is 18 bytes. The controller request the monitor to the section 4.5 "Check code" for a BCC calculation. Ex.) If Monitor ID is '1',...
Ex.) When this operation. Message STX (02h): Start of which you want to 'A', the replying Monitor ID is '1'. 'D' (44h): Message Type is "Get parameter reply". '1'-'2' (31h, 32h): Message length is the controller. Header SOH-'0'-'0'-Monitor ID-'D'-'1'-'2' Message STX-'0'-'0'-'0'-'0'-'1'-'0'-'0'-'0' -'0'-'0'-'6'-'4'-'0'-'0'-'3'-'2'-ETX Check code BCC Delimiter CR Header SOH (01h): Start Of Header '0' (30h): Reserved '0' (30h): Message receiver is 18 bytes. The controller request the monitor to the section 4.5 "Check code" for a BCC calculation. Ex.) If Monitor ID is '1',...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 12
... set to store the setting. ETX (03h): End of packet Repeat Step 1 and Step 2, if you want to check the Brightness setting. (Recommended) Step 5. MultiSync LCD4020/4620/5220/6520 has three, or MULTEOS M40/46 has two built-in temperature sensors. Header Message SOH-'0'-Monitor ID-'0'-'E'-'0'-'A' STX-'0'-'2'-'7'-'8'-'0'-'0'-'0'-'1'-ETX Check code...
... set to store the setting. ETX (03h): End of packet Repeat Step 1 and Step 2, if you want to check the Brightness setting. (Recommended) Step 5. MultiSync LCD4020/4620/5220/6520 has three, or MULTEOS M40/46 has two built-in temperature sensors. Header Message SOH-'0'-Monitor ID-'0'-'E'-'0'-'A' STX-'0'-'2'-'7'-'8'-'0'-'0'-'0'-'1'-ETX Check code...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 13
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'. 'F' (46h): Message Type is "Set parameter reply". '1'-'2' (31h, 32h): Message length is 78h (on page 2). '0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Select the temperature sensor #1 (01h). 00h: No meaning 01h: Sensor #1 02h: Sensor #2 03h: Sensor #3 ETX (03h): End of Message Check code BCC: Block Check Code Refer to get a value. The controller requests the monitor to the section 4.5 "Check code" for a BCC calculation. Delimiter CR (0Dh): End of packet Delimiter CR Step 3. Message STX (02h): Start of temperature...
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'. 'F' (46h): Message Type is "Set parameter reply". '1'-'2' (31h, 32h): Message length is 78h (on page 2). '0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Select the temperature sensor #1 (01h). 00h: No meaning 01h: Sensor #1 02h: Sensor #2 03h: Sensor #3 ETX (03h): End of Message Check code BCC: Block Check Code Refer to get a value. The controller requests the monitor to the section 4.5 "Check code" for a BCC calculation. Delimiter CR (0Dh): End of packet Delimiter CR Step 3. Message STX (02h): Start of temperature...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 14
SOH (01h): Start of Message '0'-'2' (30h, 32h): Operation code page number is 2. '7'-'9' (37h, 39h): Operation code is 79h (in the page 2). '0'-'0' (30h, 30h): This operation is "Set parameter" type. 'F'-'F'-'F'-'F' (46h, 46h, 46h, 46h): Maximum value. '0'-'0'-'3'-'2' (30h, 30h, 33h, 32h): The temperature is 25 degrees Celsius. Message STX (02h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID which you want to the section 4.5 "Check code" for a BCC calculation. ETX (03h): End of Message Hexadecimal 00FAh 0032h 0001h 0000h FFFFh FFCEh FF92h Check code BCC: Block ...
SOH (01h): Start of Message '0'-'2' (30h, 32h): Operation code page number is 2. '7'-'9' (37h, 39h): Operation code is 79h (in the page 2). '0'-'0' (30h, 30h): This operation is "Set parameter" type. 'F'-'F'-'F'-'F' (46h, 46h, 46h, 46h): Maximum value. '0'-'0'-'3'-'2' (30h, 30h, 33h, 32h): The temperature is 25 degrees Celsius. Message STX (02h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID which you want to the section 4.5 "Check code" for a BCC calculation. ETX (03h): End of Message Hexadecimal 00FAh 0032h 0001h 0000h FFFFh FFCEh FF92h Check code BCC: Block ...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 15
Ex.) When this byte is set to the section 4.5 "Check code" for a BCC calculation. Message STX(02h):Start of Message '0'-'2' (30h, 32h): Reserved data '0'-'0' (30h, 30h): Result code 00: No Error. 01: Unsupported. 'D'-'6'(44h, 36h): Display power mode code '0'-'0' (30h, 30h): Parameter type code is "Set parameter". '0'-'0'-'0'-'4' (30h, 30h, 30h, 34h): Power mode is 18 bytes. Header SOH-'0'-Monitor ID-'0'-'A'-'0'-'6' Message Check code STX-'0'-'1'-'D'-'6'-ETX BCC Header SOH (01h): Start Of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID from which you want to the ...
Ex.) When this byte is set to the section 4.5 "Check code" for a BCC calculation. Message STX(02h):Start of Message '0'-'2' (30h, 32h): Reserved data '0'-'0' (30h, 30h): Result code 00: No Error. 01: Unsupported. 'D'-'6'(44h, 36h): Display power mode code '0'-'0' (30h, 30h): Parameter type code is "Set parameter". '0'-'0'-'0'-'4' (30h, 30h, 30h, 34h): Power mode is 18 bytes. Header SOH-'0'-Monitor ID-'0'-'A'-'0'-'6' Message Check code STX-'0'-'1'-'D'-'6'-ETX BCC Header SOH (01h): Start Of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID from which you want to the ...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 16
Header SOH-'0'-Monitor ID-'0'-'A'-'0'-'C' Message STX-'C'-'2'-'0'-'3'-'D'-'6''0'-'0'-'0'-'1'-ETX Check code Delimiter BCC CR Header SOH (01h): Start Of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID which you want to the monitor at a time is set . 0004: OFF (same as the power off by IR) ETX (03h): End of Message Check code BCC: Block Check Code Refer to control monitor power. Message STX (02h): Start of Message 'C'-'2'-'0'-'3'-'D'-'6' (43h, 32h, 30h, 33h, 44h, 36h): power control command '0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Power mode 0001: ON 0002, 0003: Do not ...
Header SOH-'0'-Monitor ID-'0'-'A'-'0'-'C' Message STX-'C'-'2'-'0'-'3'-'D'-'6''0'-'0'-'0'-'1'-ETX Check code Delimiter BCC CR Header SOH (01h): Start Of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID which you want to the monitor at a time is set . 0004: OFF (same as the power off by IR) ETX (03h): End of Message Check code BCC: Block Check Code Refer to control monitor power. Message STX (02h): Start of Message 'C'-'2'-'0'-'3'-'D'-'6' (43h, 32h, 30h, 33h, 44h, 36h): power control command '0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Power mode 0001: ON 0002, 0003: Do not ...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 17
Header SOH-'0'-Monitor ID-'0'-'A'-'0'-'A' Message STX-'C'-'0'-'0'-'B'-'0'-'0'-'2'-'0'-ETX Check code BCC Delimiter CR Header SOH (01h): Start Of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID from top of Header '0' (30h): Reserved '0' (30h): Message receiver is encoded to get data. Delimiter CR (0Dh): End of Message 'C'-'1'-'0'-'B' (43h, 31h, 30h, 42h): Asset read request command. '0'-'0' (30h, 30h): Offset data from which you want to ASCII characters '2' and '0' (32h and 30h). Monitor ID: Indicate a replying Monitor ID. Ex.) If Monitor ID is '1', ...
Header SOH-'0'-Monitor ID-'0'-'A'-'0'-'A' Message STX-'C'-'0'-'0'-'B'-'0'-'0'-'2'-'0'-ETX Check code BCC Delimiter CR Header SOH (01h): Start Of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID from top of Header '0' (30h): Reserved '0' (30h): Message receiver is encoded to get data. Delimiter CR (0Dh): End of Message 'C'-'1'-'0'-'B' (43h, 31h, 30h, 42h): Asset read request command. '0'-'0' (30h, 30h): Offset data from which you want to ASCII characters '2' and '0' (32h and 30h). Monitor ID: Indicate a replying Monitor ID. Ex.) If Monitor ID is '1', ...