External Control Codes
Page 1
Control Commands 20 6. Operation Code (OP code) Table 26 7. Connectors and wiring 4 2.1 RS-232C Remote control 4 2.2 LAN control 4 III. How to read 36 7.2 Power control 38 8. Power control procedure 36... of the built-in temperature sensors 23 6.3. How to change the "Backlight" setting 20 6.2. Communication specification 5 3. EXTERNAL CONTROL NEC LCD Monitor Rev.3.8 INDEX I. Communication Parameter 5 3.1 RS-232C Remote control 5 3.2 LAN control 5 3.3 Communication timing 5 4. Message type 13 5.1 Get current Parameter from a monitor 13 5.2 ...
Control Commands 20 6. Operation Code (OP code) Table 26 7. Connectors and wiring 4 2.1 RS-232C Remote control 4 2.2 LAN control 4 III. How to read 36 7.2 Power control 38 8. Power control procedure 36... of the built-in temperature sensors 23 6.3. How to change the "Backlight" setting 20 6.2. Communication specification 5 3. EXTERNAL CONTROL NEC LCD Monitor Rev.3.8 INDEX I. Communication Parameter 5 3.1 RS-232C Remote control 5 3.2 LAN control 5 3.3 Communication timing 5 4. Message type 13 5.1 Get current Parameter from a monitor 13 5.2 ...
External Control Codes
Page 4
II. Connectors and wiring 2.1 RS-232C Remote control Connector: 9-pin D-Sub Cable: Cross (reversed) cable or null modem cable (Please refer "Controlling the LCD monitor via RS-232C Remote control" on User's manual.) 2.2 LAN control Connector: RJ-45 10/100 BASE-T Cable: Category 5 or higher LAN cable (Please refer "Controlling the LCD monitor via LAN control" on User's manual.) (4/72) Preparation 2.
II. Connectors and wiring 2.1 RS-232C Remote control Connector: 9-pin D-Sub Cable: Cross (reversed) cable or null modem cable (Please refer "Controlling the LCD monitor via RS-232C Remote control" on User's manual.) 2.2 LAN control Connector: RJ-45 10/100 BASE-T Cable: Category 5 or higher LAN cable (Please refer "Controlling the LCD monitor via LAN control" on User's manual.) (4/72) Preparation 2.
External Control Codes
Page 5
... or more. 3.3 Communication timing The controller should wait for a packet interval before next command is received for the LCD monitor. (5/72) Communication Parameter 3.1 RS-232C Remote control (1) Communication system (2) Interface (3) Baud rate (4) Data length (5) Parity (6) Stop bit (7) Communication code Asynchronous RS-232C 9600bps 8bits None 1 bit ASCII 3.2 LAN control (1) Communication system...
... or more. 3.3 Communication timing The controller should wait for a packet interval before next command is received for the LCD monitor. (5/72) Communication Parameter 3.1 RS-232C Remote control (1) Communication system (2) Interface (3) Baud rate (4) Data length (5) Parity (6) Stop bit (7) Communication code Asynchronous RS-232C 9600bps 8bits None 1 bit ASCII 3.2 LAN control (1) Communication system...
Specification Brochure
Page 1
...;• Full bi-directional RS-232 control and ethernet control allow individual and groupaddressable control, including email diagnostics •• Compatibility with NEC control software PD Comms Tool and NaViSet Administrator 2 •• Custom input detect feature to prioritize active inputs •• Expanded ... OPS expansion slot for maximum versatility •• Extensive control and diagnostic communication provide the highest level of remote management •• IR and Button Lock options for protecting against unnecessary setting changes www.necdisplay.com
...;• Full bi-directional RS-232 control and ethernet control allow individual and groupaddressable control, including email diagnostics •• Compatibility with NEC control software PD Comms Tool and NaViSet Administrator 2 •• Custom input detect feature to prioritize active inputs •• Expanded ... OPS expansion slot for maximum versatility •• Extensive control and diagnostic communication provide the highest level of remote management •• IR and Button Lock options for protecting against unnecessary setting changes www.necdisplay.com
Specification Brochure
Page 2
WxHxD) Net Weight (without stand; Specifications for E705/E805/E905 MODEL LCD MODULE Panel Technology Viewable Image Size Native Resolution Brightness (Typical/Max) Contrast Ratio (Typical) Viewing Angle Aspect Ratio Active Screen Area (W x H) ... (without stand) VESA Hole Configuration ENVIRONMENTAL CONDITIONS Operating Temperature Operating Humidity Operating Altitude LIMITED WARRANTY ADDITIONAL FEATURES SHIPS WITH OPTIONAL ACCESSORIES Single Board Computers Other E705 UV2A 70" 360/450 cd/m2 4000:1 176° Vert. / 176 Hor.(88U/88D/88L/88R) @CR>10 60.6 x 34.1in. / 1538.9 x 865.6mm More...
WxHxD) Net Weight (without stand; Specifications for E705/E805/E905 MODEL LCD MODULE Panel Technology Viewable Image Size Native Resolution Brightness (Typical/Max) Contrast Ratio (Typical) Viewing Angle Aspect Ratio Active Screen Area (W x H) ... (without stand) VESA Hole Configuration ENVIRONMENTAL CONDITIONS Operating Temperature Operating Humidity Operating Altitude LIMITED WARRANTY ADDITIONAL FEATURES SHIPS WITH OPTIONAL ACCESSORIES Single Board Computers Other E705 UV2A 70" 360/450 cd/m2 4000:1 176° Vert. / 176 Hor.(88U/88D/88L/88R) @CR>10 60.6 x 34.1in. / 1538.9 x 865.6mm More...
User's Manual
Page 2
E805...English-46 Pin Assignment...English-47 Manufacturer's Recycling and Energy Information English-48 E705...English-45 Specifications - Index Declaration of conformity...English-1 Important Information...English-2 WARNING...English-2 CAUTION...English-2 Safety...Attaching Mounting Accessories...English-6 Parts Name and Functions...English-8 Control Panel...English-8 Terminal Panel...English-9 Wireless Remote Control...English-10 Operating Range for the Remote Control English-11 Setup...English-12 Connections...English-14 Wiring Diagram...English-14 Connecting a Personal Computer English-...
E805...English-46 Pin Assignment...English-47 Manufacturer's Recycling and Energy Information English-48 E705...English-45 Specifications - Index Declaration of conformity...English-1 Important Information...English-2 WARNING...English-2 CAUTION...English-2 Safety...Attaching Mounting Accessories...English-6 Parts Name and Functions...English-8 Control Panel...English-8 Terminal Panel...English-9 Wireless Remote Control...English-10 Operating Range for the Remote Control English-11 Setup...English-12 Connections...English-14 Wiring Diagram...English-14 Connecting a Personal Computer English-...
User's Manual
Page 6
...power outlet and has been approved by and complies with washer (M4 x 10) x 1 Clamp x 1 CD-ROM Setup Manual Setup Manual Wireless Remote Control and AAA Batteries * Remember to be shipped. Contents Your new monitor box* should contain the following: • LCD monitor • Power cord...*1 • Video Signal Cable • Wireless Remote Control and AAA Batteries • Setup Manual • Clamp x 1 • Screw with washer (M4 x 10) x 1 • CD-ROM Video Signal ...
...power outlet and has been approved by and complies with washer (M4 x 10) x 1 Clamp x 1 CD-ROM Setup Manual Setup Manual Wireless Remote Control and AAA Batteries * Remember to be shipped. Contents Your new monitor box* should contain the following: • LCD monitor • Power cord...*1 • Video Signal Cable • Wireless Remote Control and AAA Batteries • Setup Manual • Clamp x 1 • Screw with washer (M4 x 10) x 1 • CD-ROM Video Signal ...
User's Manual
Page 10
... button (INPUT) Acts as button to move the highlighted area down simultaneously for more than 3 seconds. Acts as SET/POINT ZOOM button within OSD menu. I Remote control sensor and Power Indicator Receives the signal from the...
... button (INPUT) Acts as button to move the highlighted area down simultaneously for more than 3 seconds. Acts as SET/POINT ZOOM button within OSD menu. I Remote control sensor and Power Indicator Receives the signal from the...
User's Manual
Page 12
... previous menu within OSD menu settings. See page 18. L EXIT button Returns to set and change passwords, change channel and set REMOTE ID. See page 21. English-10 CINEMA: for moving images such as button to move the highlighted area up or down to ...[CINEMA], [CUSTOM1], [CUSTOM2]. Activates POINT ZOOM function when OSD menu is released when activating IMAGE FLIP. STILL CAPTURE button: Captures still picture. Wireless Remote Control A POWER button Switches the power on /off the menu mode. CUSTOM1 and CUSTOM2: activate auto dimming function. P VOLUME UP/DOWN button (VOL...
... previous menu within OSD menu settings. See page 18. L EXIT button Returns to set and change passwords, change channel and set REMOTE ID. See page 21. English-10 CINEMA: for moving images such as button to move the highlighted area up or down to ...[CINEMA], [CUSTOM1], [CUSTOM2]. Activates POINT ZOOM function when OSD menu is released when activating IMAGE FLIP. STILL CAPTURE button: Captures still picture. Wireless Remote Control A POWER button Switches the power on /off the menu mode. CUSTOM1 and CUSTOM2: activate auto dimming function. P VOLUME UP/DOWN button (VOL...
User's Manual
Page 13
...10 ft.). MTS button*1 *1: This button's action depends on which option board you use . Refer to the main picture and sub picture. If the remote control gets wet, wipe it dry immediately. • Avoid exposure to heat and steam. • Other than to change the sub picture size by pressing...Yes OPTION Yes Yes Yes Yes Yes No Yes HDMI2 Yes Yes Yes Yes Yes Yes No REMOTE ID button Activates REMOTE ID function. Use the remote control within a distance of about 7 m (23 ft.) from remote control sensor or at a horizontal and vertical angle of within 30° within a distance...
...10 ft.). MTS button*1 *1: This button's action depends on which option board you use . Refer to the main picture and sub picture. If the remote control gets wet, wipe it dry immediately. • Avoid exposure to heat and steam. • Other than to change the sub picture size by pressing...Yes OPTION Yes Yes Yes Yes Yes No Yes HDMI2 Yes Yes Yes Yes Yes Yes No REMOTE ID button Activates REMOTE ID function. Use the remote control within a distance of about 7 m (23 ft.) from remote control sensor or at a horizontal and vertical angle of within 30° within a distance...
User's Manual
Page 14
Failure to open the cover. To install or replace batteries: NEC recommends the following battery use the Remote Control for cooling the option board. NOTE: If you do not intend to use : • Place "AAA" size batteries matching the (+) and (-) signs on each ... cord. IMPORTANT: Lay the protective sheet, which was wrapped around the LCD monitor when it may result in leaks or bursting. Install the remote control batteries The remote control is powered by using the "HEAT STATUS" control in an enclosed area or if the LCD panel is lower than the normal operating...
Failure to open the cover. To install or replace batteries: NEC recommends the following battery use the Remote Control for cooling the option board. NOTE: If you do not intend to use : • Place "AAA" size batteries matching the (+) and (-) signs on each ... cord. IMPORTANT: Lay the protective sheet, which was wrapped around the LCD monitor when it may result in leaks or bursting. Install the remote control batteries The remote control is powered by using the "HEAT STATUS" control in an enclosed area or if the LCD panel is lower than the normal operating...
User's Manual
Page 16
Using an audio cable with each separate piece of the monitor image. Use an audio cable without a built-in remote control DisplayPort DVI HDMI RGB/HV Y/Pb/Pr OPTION HDMI DisplayPort DVI HDMI RGB/HV OPTION HDMI English-14 Wiring Diagram DVD Player Stereo Amplifier ...
Using an audio cable with each separate piece of the monitor image. Use an audio cable without a built-in remote control DisplayPort DVI HDMI RGB/HV Y/Pb/Pr OPTION HDMI DisplayPort DVI HDMI RGB/HV OPTION HDMI English-14 Wiring Diagram DVD Player Stereo Amplifier ...
User's Manual
Page 18
OFF Main Power Switch ON Power Button Using the remote control English-16 Basic Operation Power ON and OFF Modes The LCD monitor power indicator will turn green while powered on and will turn red or amber while powered off. NOTE: The Main Power Switch must be in the ON position in order to power up the monitor using the remote control or the Power Button.
OFF Main Power Switch ON Power Button Using the remote control English-16 Basic Operation Power ON and OFF Modes The LCD monitor power indicator will turn green while powered on and will turn red or amber while powered off. NOTE: The Main Power Switch must be in the ON position in order to power up the monitor using the remote control or the Power Button.
User's Manual
Page 20
A Input Name B Audio input mode C Picture aspect D Input Signal Information 5 Sub picture information Picture Mode DVI, VGA, DPORT STANDARD sRGB CUSTOM1 CUSTOM2 HIGHBRIGHT HDMI, Y/Pb/Pr, HDMI2 STANDARD CINEMA CUSTOM1 CUSTOM2 HIGHBRIGHT English-18 Press the DISPLAY button on the remote to bring up the Information OSD. Information OSD The Information OSD provides information such as: Input Source, Picture Size, etc.
A Input Name B Audio input mode C Picture aspect D Input Signal Information 5 Sub picture information Picture Mode DVI, VGA, DPORT STANDARD sRGB CUSTOM1 CUSTOM2 HIGHBRIGHT HDMI, Y/Pb/Pr, HDMI2 STANDARD CINEMA CUSTOM1 CUSTOM2 HIGHBRIGHT English-18 Press the DISPLAY button on the remote to bring up the Information OSD. Information OSD The Information OSD provides information such as: Input Source, Picture Size, etc.
User's Manual
Page 21
... or DOWN button to be available depending on the model or optional equipment. Press UP or DOWN, PLUS Press EXIT or MINUS button to select. Remote Control Press UP or DOWN button to select. Control Panel OSD screen English-19 Press INPUT button to decide. Input source Main Menu Icons Main...
... or DOWN button to be available depending on the model or optional equipment. Press UP or DOWN, PLUS Press EXIT or MINUS button to select. Remote Control Press UP or DOWN button to select. Control Panel OSD screen English-19 Press INPUT button to decide. Input source Main Menu Icons Main...
User's Manual
Page 26
... LOCK or CUSTOM LOCK. ALL LOCK Locks all INPUT buttons are activated. CUSTOM LOCK Selects which option board you prefer to the wireless remote control buttons. VOLUME: When UNLOCK is selected, VOLUME (+) button and VOLUME (-) buttons are locked. When LOCK is selected, sets minimum... and maximum volume between being controlled by the wireless remote control. The unselected buttons are locked. When LOCK is selected, all buttons at the front of the monitor. It takes more time ...
... LOCK or CUSTOM LOCK. ALL LOCK Locks all INPUT buttons are activated. CUSTOM LOCK Selects which option board you prefer to the wireless remote control buttons. VOLUME: When UNLOCK is selected, VOLUME (+) button and VOLUME (-) buttons are locked. When LOCK is selected, sets minimum... and maximum volume between being controlled by the wireless remote control. The unselected buttons are locked. When LOCK is selected, all buttons at the front of the monitor. It takes more time ...
User's Manual
Page 27
... option allows you to register the IP address or subnet mask number obtained from your DHCP server. CONTROL LOCK: Security password is required when the remote control button or control button on . NOTE: Consult your IP address of the side borders when a 4:3 image is lost . AUTO IP ADDRESS: Set your network... required when the monitor power is on the monitor is pressed. BOTH LOCK: Security password is required when the monitor power is on, or the remote control button or control button on the monitor is pressed.
... option allows you to register the IP address or subnet mask number obtained from your DHCP server. CONTROL LOCK: Security password is required when the remote control button or control button on . NOTE: Consult your IP address of the side borders when a 4:3 image is lost . AUTO IP ADDRESS: Set your network... required when the monitor power is on the monitor is pressed. BOTH LOCK: Security password is required when the monitor power is on, or the remote control button or control button on the monitor is pressed.
User's Manual
Page 31
... SCHEDULE LIST DATE & TIME RESET NOTE: If schedules are overlapping then the schedule with the highest number will turn off the monitor by remote control, or use Power Management or use as Image Persistence. As with the lowest number. When not in use "Screen Saver Mode" of... on which the schedule will have priority over the LCD surface, the LCD surface is installed over the schedule with all personal display devices, NEC DISPLAY SOLUTIONS recommends displaying moving images and using the up and down buttons. Please set "SCREEN SAVER", "DATE &TIME" and "SCHEDULE SETTINGS...
... SCHEDULE LIST DATE & TIME RESET NOTE: If schedules are overlapping then the schedule with the highest number will turn off the monitor by remote control, or use Power Management or use as Image Persistence. As with the lowest number. When not in use "Screen Saver Mode" of... on which the schedule will have priority over the LCD surface, the LCD surface is installed over the schedule with all personal display devices, NEC DISPLAY SOLUTIONS recommends displaying moving images and using the up and down buttons. Please set "SCREEN SAVER", "DATE &TIME" and "SCHEDULE SETTINGS...
User's Manual
Page 32
...input the Monitor ID (1-100) of the display to be assigned under the MULTI DISPLAY menu in white on the remote control, use REMOTE ID:3 Remote works Use the remote control to operate a monitor that specific Monitor ID number. For example: if there are not the same. In ...assigned a Monitor ID number. The MONITOR ID number is "0", then all displays in range will be specified via remote. Remote Control Function REMOTE CONTROL ID FUNCTION REMOTE CONTROL ID The remote control can be used to operate the monitor having that has a specific MONITOR ID number assigned to it. ...
...input the Monitor ID (1-100) of the display to be assigned under the MULTI DISPLAY menu in white on the remote control, use REMOTE ID:3 Remote works Use the remote control to operate a monitor that specific Monitor ID number. For example: if there are not the same. In ...assigned a Monitor ID number. The MONITOR ID number is "0", then all displays in range will be specified via remote. Remote Control Function REMOTE CONTROL ID FUNCTION REMOTE CONTROL ID The remote control can be used to operate the monitor having that has a specific MONITOR ID number assigned to it. ...
User's Manual
Page 33
English Controlling the LCD monitor via RS-232C Remote Control This LCD monitor can be controlled by a personal computer are: • Power ON or OFF. • Switching between input signals. • Sound Mute ON ...
English Controlling the LCD monitor via RS-232C Remote Control This LCD monitor can be controlled by a personal computer are: • Power ON or OFF. • Switching between input signals. • Sound Mute ON ...