Motorola M2004-I400 Support and Manuals
Get Help and Manuals for this Motorola item
This item is in your list!
View All Support Options Below
Free Motorola M2004-I400 manuals!
Problems with Motorola M2004-I400?
Ask a Question
Free Motorola M2004-I400 manuals!
Problems with Motorola M2004-I400?
Ask a Question
Popular Motorola M2004-I400 Manual Pages
Operating Instructions - Page 2
M2004-I418 Special Operating Instructions (73-39696-418)
Revision A: February 2004
Contents
Features 3 Plural Stage Bar Codes 3 Custom Default Parameter Settings 4 Decode 2-Stage Bar Codes 6 Plural Stage Mode Select Bar Codes 7
RC Mode Plural Stage Enable/Disable Bar Codes 8 NRC Mode Plural Stage Select 10 Plural Stage Inter-Decode Wait Time......11 Plural Stage Decode Inhibit Timeout ...
Operating Instructions - Page 3
... the other . In this is set through the NRC Mode Plural Stage Select parameter.
See Plural Stage ADF Rule on page 23 for details regarding the format of the recognition codes.
• NRC Mode does not require the use of plural stage decoding are supported. M2004-I418 Special Operating Instructions (73-39696-418)
Revision A: February...
Operating Instructions - Page 4
... allow the user to RC Mode)
Disabled
Decode 3-Stage bar codes (Ap- See Clearing Recognition Codes on page 34 for others)
*Scanning "Set Defaults" will not restore the row recognition codes and associated location values to RC Mode)
Decode 4-Stage bar codes (Ap-
M2004-I418 Special Operating Instructions (73-39696-418)
Revision A: February 2004
details regarding the...
Operating Instructions - Page 5
... shown in this table.
mum)
*Scanning "Set Defaults" will not restore the row recognition codes and associated location values to clear stored recognition codes. M2004-I418 Special Operating Instructions (73-39696-418)
Revision A: February 2004
Parameter
Default Setting
All Row Recognition Codes
None (i.e., Not Set)
All Position Values
0 (i.e., Not Set)
All Relative Start Position...
Operating Instructions - Page 6
M2004-I418 Special Operating Instructions (73-39696-418)
Revision A: February 2004
Decode 2-Stage Bar Codes
When Decode 2-Stage Bar Codes is enabled, the following parameter values are set: 2 Stage, Row 1, Code 1 Characters>:97 2 Stage, Row 1, Code 1 position value> for first character "9":01 2 Stage, Row 1, Code 1 position value> for second character "7":02
2 Stage, Row 2, Code 1 Characters>:19 2...
Operating Instructions - Page 7
... scanner attempts to scan the number of bar codes specified by the setting of the following bar codes to decode and transmit plural stage bar codes.
NRC Mode (Non-recognition Code Mode)
7 M2004-I418 Special Operating Instructions (73-39696-418)
Revision A: February 2004
Plural Stage Mode Select Bar Codes
Scan one of the NRC Mode Plural Stage Select...
Operating Instructions - Page 10
M2004-I418 Special Operating Instructions (73-39696-418)
Revision A: February 2004
NRC Mode Plural Stage Select When the Plural Stage Mode is set to NRC Mode, scan the bar code below that corresponds to the number of unique barcodes the scanner should attempt to decode before transmitting. Decode And Transmit Any 2
Decode And Transmit Any 3
Decode And Transmit Any 4
Decode And Transmit Any 5
10
Operating Instructions - Page 11
... 5.0 seconds in .1 second increments), scan the bar code below followed by two numeric bar codes, starting on page 39. Plural Stage Decode Inhibit Timeout
11 M2004-I418 Special Operating Instructions (73-39696-418)
Revision A: February 2004
Plural Stage Inter-Decode Wait Time When a bar code from a plural stage set is decoded, this time expires, the previous...
Operating Instructions - Page 12
... decodes of any of the single bar codes making up this timeout has expired.
Plural Stage Single Symbol Timeout
12 M2004-I418 Special Operating Instructions (73-39696-418)
Revision A: February 2004
Plural Stage Same Single Symbol Timeout This parameter sets the time the scanner waits after a plural stage bar code is seen, or if this plural stage...
Operating Instructions - Page 18
M2004-I418 Special Operating Instructions (73-39696-418)
Revision A: February 2004
Row Prefix/Suffix Values To set the prefix/suffix values for the four digit values that correspond to the various keystrokes. See the ASCII Equivalent Tables in the Cyclone™ M2000 Series Product Reference Guide for plural stage row data, scan the corresponding bar code followed...
Operating Instructions - Page 21
... several ADF rules (some of plural stage data. M2004-I418 Special Operating Instructions (73-39696-418)
Revision A: February 2004
Plural Stage ADF Rule A new ADF criteria and action allow formatting of which use the When Plural Stage Scan Data
21 Scan the "Save Rule" bar code from the Cyclone™ M2000 Series Product Reference Guide).
Operating Instructions - Page 22
... the Cyclone™ M2000 Series Product Reference Guide may be used.
22 Normal Scan Data Transmission Option
This allows the user to the default rule. The "Scan Options" bar code sets a When Scan Any criteria, which is the highest priority criteria and overrides the When Plural Stage Scan Data criteria. M2004-I418 Special Operating Instructions (73...
Operating Instructions - Page 23
... 4Stage). M2004-I418 Special Operating Instructions (73-39696-418)
Revision A: February 2004
Plural Stage Row Recognition Codes
Up to two different recognition codes can be programmed for each row within each character a position value must be programmed to tell the scanner what position in the Cyclone™ M2000 Series Product Reference Guide.
3. Programming Recognition Code Position Values...
Operating Instructions - Page 37
... Scan the "SRC Done" bar code below to store the characters. Scan the "Set SRC" bar code below to select new supplemental recognition characters.
M2004-I418 Special Operating Instructions (73-39696-418)
Revision A: February 2004
To set a Supplemental Recognition Character:
1. Scan up to three alphanumeric bar codes from the CycloneTM M2000 Series Product Reference Guide.
3. Set SRC
2.
Operating Instructions - Page 38
AGC Control Off (Default)
AGC Control Off
38 M2004-I418 Special Operating Instructions (73-39696-418)
Revision A: February 2004
AGC Control AGC Control is used by the M2004-I400 standard product to be shut off, effectively increasing the chance of operation AGC Control has to prevent mis-decodes and double decodes when in Omni-...
Motorola M2004-I400 Reviews
Do you have an experience with the Motorola M2004-I400 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Motorola yet.
Earn 750 points for your review!