Installation Guide
Page 4
NOTE: Do not use leveling legs supplied with dryer if installing with dryer) ■■Vent clamps ■■Vent elbows and vent work 4 Parts needed for gas installations: 8" or 10" pipe wrench 8" or 10" adjustable wrench (for all parts are included. Tools needed for gas connections) Flat-blade screwdriver #2 Phillips screwdriver ¼" and 5/16...
NOTE: Do not use leveling legs supplied with dryer if installing with dryer) ■■Vent clamps ■■Vent elbows and vent work 4 Parts needed for gas installations: 8" or 10" pipe wrench 8" or 10" adjustable wrench (for all parts are included. Tools needed for gas connections) Flat-blade screwdriver #2 Phillips screwdriver ¼" and 5/16...
Installation Guide
Page 5
... mm) above floor. Optional Equipment: (Not supplied with elbow. See "Venting Requirements." ■■A separate 15 or 20 amp circuit for a gas dryer or 30 amp circuit for exhaust vent with dryer) Refer to your Use and Care Guide for information about accessories available for proper exhaust installation. See "Venting Requirements." 5 Parts needed...
... mm) above floor. Optional Equipment: (Not supplied with elbow. See "Venting Requirements." ■■A separate 15 or 20 amp circuit for a gas dryer or 30 amp circuit for exhaust vent with dryer) Refer to your Use and Care Guide for information about accessories available for proper exhaust installation. See "Venting Requirements." 5 Parts needed...
Installation Guide
Page 6
... for ease of installation and servicing. ■■Additional clearances might be required for wall, door, floor moldings, dryer venting, and gas line. ■■Additional spacing should be large enough to allow door to fully open. Recommended installation clearances... codes limit, or do not permit, installation of the line. Additional installation requirements: This dryer is allowed for straight back venting only. Be sure wall receptacle is within reach of gas dryers: ■■Mobile Home Installation Hold-down Kit Part Number 346764 is allowed for straight back...
... for ease of installation and servicing. ■■Additional clearances might be required for wall, door, floor moldings, dryer venting, and gas line. ■■Additional spacing should be large enough to allow door to fully open. Recommended installation clearances... codes limit, or do not permit, installation of the line. Additional installation requirements: This dryer is allowed for straight back venting only. Be sure wall receptacle is within reach of gas dryers: ■■Mobile Home Installation Hold-down Kit Part Number 346764 is allowed for straight back...
Installation Guide
Page 7
... installed and grounded in accordance with a quali ed electrician or service representative or personnel if you are in your dryer. SAVE THESE INSTRUCTIONS GAS SUPPLY REQUIREMENTS GAS DRYER POWER HOOKUP ELECTRICAL REQUIREMENTS ■■120 Volt, 60 Hz, AC only, 15- LP Gas Conversion: IMPORTANT: Conversion must be made to convert the appliance from the...
... installed and grounded in accordance with a quali ed electrician or service representative or personnel if you are in your dryer. SAVE THESE INSTRUCTIONS GAS SUPPLY REQUIREMENTS GAS DRYER POWER HOOKUP ELECTRICAL REQUIREMENTS ■■120 Volt, 60 Hz, AC only, 15- LP Gas Conversion: IMPORTANT: Conversion must be made to convert the appliance from the...
Installation Guide
Page 8
...pipe. E C A 11/2" (38 mm) *53/4" (146 mm) 3⁄8" NPT dryer gas pipe * NOTE: If the dryer is acceptable for gas appliances, ANSI Z21.24 or CSA 6.10. D B A. 3⁄8" flexible gas connector B. 3⁄8" pipe to the dryer. Use an elbow and a 3⁄8" flare x 3⁄8" NPT adapter fitting between the ...Use an elbow and a 3⁄8" flare x 3⁄8" NPT adapter fitting between the stainless steel gas connector and the dryer gas pipe, as needed to prevent kinking. For a garage installation, the gas pipe height must be an additional 10" (254 mm) or 15.5" (394 mm) from ...
...pipe. E C A 11/2" (38 mm) *53/4" (146 mm) 3⁄8" NPT dryer gas pipe * NOTE: If the dryer is acceptable for gas appliances, ANSI Z21.24 or CSA 6.10. D B A. 3⁄8" flexible gas connector B. 3⁄8" pipe to the dryer. Use an elbow and a 3⁄8" flare x 3⁄8" NPT adapter fitting between the ...Use an elbow and a 3⁄8" flare x 3⁄8" NPT adapter fitting between the stainless steel gas connector and the dryer gas pipe, as needed to prevent kinking. For a garage installation, the gas pipe height must be an additional 10" (254 mm) or 15.5" (394 mm) from ...
Installation Guide
Page 9
... there are no longer visible. Place a carton corner post from gas pipe. Closed valve B. Then, test all non-flared male fittings. Flared male fitting B. Connect gas supply to dryer. Screw in supply line; Screw legs into leg holes by brushing...back edge of pipe fittings must use a wrench to gas pipe. A B A. 3⁄8" flexible gas connector B. 3⁄8" dryer gas pipe C. 3⁄8" to 3⁄8" pipe elbow D. 3 ⁄8" pipe-to-flare adapter fitting A combination of dryer. Slide the dryer on an approved noncorrosive leak-detection solution. If flexible...
... there are no longer visible. Place a carton corner post from gas pipe. Closed valve B. Then, test all non-flared male fittings. Flared male fitting B. Connect gas supply to dryer. Screw in supply line; Screw legs into leg holes by brushing...back edge of pipe fittings must use a wrench to gas pipe. A B A. 3⁄8" flexible gas connector B. 3⁄8" dryer gas pipe C. 3⁄8" to 3⁄8" pipe elbow D. 3 ⁄8" pipe-to-flare adapter fitting A combination of dryer. Slide the dryer on an approved noncorrosive leak-detection solution. If flexible...
Installation Guide
Page 10
... 45° elbows provide better airflow than 90° elbows. Clamps: ■■ Use clamps to seal all governing codes and ordinances. Dryer exhaust must not be connected or secured with rigid metal or flexible metal vents. IMPORTANT: Observe all joints. ■■ Exhaust vent must ...and catch lint. NOTE: If using an existing vent system, clean lint from ground or any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of fire, this dryer MUST BE EXHAUSTED OUTDOORS. Replace plastic or metal foil vents with screws or other fastening devices ...
... 45° elbows provide better airflow than 90° elbows. Clamps: ■■ Use clamps to seal all governing codes and ordinances. Dryer exhaust must not be connected or secured with rigid metal or flexible metal vents. IMPORTANT: Observe all joints. ■■ Exhaust vent must ...and catch lint. NOTE: If using an existing vent system, clean lint from ground or any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of fire, this dryer MUST BE EXHAUSTED OUTDOORS. Replace plastic or metal foil vents with screws or other fastening devices ...
Installation Guide
Page 12
...of 90° elbows Type of vent to the cold water faucet using straightest path possible. Example: An electric model would be DALV - GAS - Do not use of box/louvered hoods will help achieve best drying performance. Periodically inspect and replace hoses if bulges, kinks, cuts,... other fastening devices that will improve venting regardless of hose failure. NOTE: Replace inlet hoses after 5 years of use caulking compound to dryer location using the new inlet hoses (not supplied). Record hose installation or replacement dates on the serial number plate in the inner door ...
...of 90° elbows Type of vent to the cold water faucet using straightest path possible. Example: An electric model would be DALV - GAS - Do not use of box/louvered hoods will help achieve best drying performance. Periodically inspect and replace hoses if bulges, kinks, cuts,... other fastening devices that will improve venting regardless of hose failure. NOTE: Replace inlet hoses after 5 years of use caulking compound to dryer location using the new inlet hoses (not supplied). Record hose installation or replacement dates on the serial number plate in the inner door ...
Installation Guide
Page 14
... of dryer from front to operate correctly. After dryer is clean. Dryer vent must be level for levelness. NOTE: The dryer must fit over dryer exhaust outlet and inside exhaust hood. CONNECT VENT 1. Level dryer Place level here Using a 4" (102 mm) clamp, connect vent to crush or kink vent or flexible gas line.... Adjust leveling legs Not Level If dryer is secured to adjust legs up or down, and check again for the moisture sensing system to back. Not Level LEVEL 2. Check...
... of dryer from front to operate correctly. After dryer is clean. Dryer vent must be level for levelness. NOTE: The dryer must fit over dryer exhaust outlet and inside exhaust hood. CONNECT VENT 1. Level dryer Place level here Using a 4" (102 mm) clamp, connect vent to crush or kink vent or flexible gas line.... Adjust leveling legs Not Level If dryer is secured to adjust legs up or down, and check again for the moisture sensing system to back. Not Level LEVEL 2. Check...
Installation Guide
Page 15
...q If you have all of scale through steps to be sure that the flexible gas line is first heated. Gas Models q Plug into a grounded outlet. q Check for models with a damp cloth to remove the door. If dryer will not start, check the following instructions are now installed. NOTE: You may...Using a T25® screwdriver, remove the 4 screws securing the door hinge to the dryer and lift up and out to remove any tape remaining on a soft towel or other non-scratch surface. q Check that gas supply is not crushed or kinked. single handle 1. q Be sure the water faucets ...
...q If you have all of scale through steps to be sure that the flexible gas line is first heated. Gas Models q Plug into a grounded outlet. q Check for models with a damp cloth to remove the door. If dryer will not start, check the following instructions are now installed. NOTE: You may...Using a T25® screwdriver, remove the 4 screws securing the door hinge to the dryer and lift up and out to remove any tape remaining on a soft towel or other non-scratch surface. q Check that gas supply is not crushed or kinked. single handle 1. q Be sure the water faucets ...
Dimension Guide
Page 1
...doors with elbow. PRODUCT MODEL NUMBERS MGD3500F, MGD5500F, MGD8200F Front view: 27" (686 mm) 383/4" Min. (984 mm) 39" Max. (990 mm) Gas Dryer Side view: Bottom view: Back view: 61/4" (159 mm) Recommended Installation Spacing: 53/4"* (146 mm) Water inlet (Steam Models Only) Vent 297/8"* (...(457 mm) 3" (76 mm) 48 in.2 min. (310 cm2) 24 in the top and bottom of 5" (127 mm) clearance behind dryer for recessed area or closet installation All dimensions show recommended and minimum spacing allowed. W10775221A 12/2015 For closet installation, with a door, minimum ventilation ...
...doors with elbow. PRODUCT MODEL NUMBERS MGD3500F, MGD5500F, MGD8200F Front view: 27" (686 mm) 383/4" Min. (984 mm) 39" Max. (990 mm) Gas Dryer Side view: Bottom view: Back view: 61/4" (159 mm) Recommended Installation Spacing: 53/4"* (146 mm) Water inlet (Steam Models Only) Vent 297/8"* (...(457 mm) 3" (76 mm) 48 in.2 min. (310 cm2) 24 in the top and bottom of 5" (127 mm) clearance behind dryer for recessed area or closet installation All dimensions show recommended and minimum spacing allowed. W10775221A 12/2015 For closet installation, with a door, minimum ventilation ...
Dimension Guide
Page 2
...9632;■ Select route that may be used . INSTALLATION REQUIREMENTS GAS SUPPLY REQUIREMENTS Gas supply: This dryer is required. Pipe-joint compounds resistant to the chart. WATER (STEAM MODELS ONLY) REQUIREMENTS The dryer must be at least 12" (305 mm) from the ground ...complete details, see Installation Instructions packed with the National Fuel Gas Code ANSI Z223.1. Dryer can result. gas. gas must be 1/2" IPS. To determine maximum exhaust length, add one 90º turn inside the dryer. Because Whirlpool Corporation policy includes a continuous commitment to improve...
...9632;■ Select route that may be used . INSTALLATION REQUIREMENTS GAS SUPPLY REQUIREMENTS Gas supply: This dryer is required. Pipe-joint compounds resistant to the chart. WATER (STEAM MODELS ONLY) REQUIREMENTS The dryer must be at least 12" (305 mm) from the ground ...complete details, see Installation Instructions packed with the National Fuel Gas Code ANSI Z223.1. Dryer can result. gas. gas must be 1/2" IPS. To determine maximum exhaust length, add one 90º turn inside the dryer. Because Whirlpool Corporation policy includes a continuous commitment to improve...
Use & Care Guide
Page 14
...are secure in the hose, freezing can damage your dryer for an extended period of replacement. Transport hose separately. 5. To Winterize the Dryer 1. Gas models only: Disconnect gas supply line pipe and remove fittings attached to secure dryer door. SPECIAL INSTRUCTIONS FOR STEAM MODELS Water Inlet Hose ...Replace inlet hose and hose screen after 5 years of hose failure. Unplug dryer or disconnect power. 2. Plug in dryer or reconnect power as described in gas supply line. 3. Gas models only: Close shut-off water faucet. 6. Steam models only: Shut off valve in...
...are secure in the hose, freezing can damage your dryer for an extended period of replacement. Transport hose separately. 5. To Winterize the Dryer 1. Gas models only: Disconnect gas supply line pipe and remove fittings attached to secure dryer door. SPECIAL INSTRUCTIONS FOR STEAM MODELS Water Inlet Hose ...Replace inlet hose and hose screen after 5 years of hose failure. Unplug dryer or disconnect power. 2. Plug in dryer or reconnect power as described in gas supply line. 3. Gas models only: Close shut-off water faucet. 6. Steam models only: Shut off valve in...
Use & Care Guide
Page 15
... fuses or circuit breakers. Check with a qualified electrician. For gas dryers, make this noise even with Steam cycle selected (depending on model) on dryer (on the dryer is blown or circuit breaker has tripped. This is open . On gas dryers, you may not have not tripped. This is running. See... Energy Saver. Hold your hand under the outside exhaust hood to recommended load size in dryer. TROUBLESHOOTING First try the solutions suggested here or visit our website at www.maytag.com/product_help - Household fuse is used in firm contact with the floor. The water pump...
... fuses or circuit breakers. Check with a qualified electrician. For gas dryers, make this noise even with Steam cycle selected (depending on model) on dryer (on the dryer is blown or circuit breaker has tripped. This is open . On gas dryers, you may not have not tripped. This is running. See... Energy Saver. Hold your hand under the outside exhaust hood to recommended load size in dryer. TROUBLESHOOTING First try the solutions suggested here or visit our website at www.maytag.com/product_help - Household fuse is used in firm contact with the floor. The water pump...