MATDCBB Green Control Board V.6.4 or newer Manual
Page 1
Use (2) LiftMaster 12Vdc 7AH (Part # MBAT). Radio Receiver Included The Chamberlain Group, Inc. 845 Larch Avenue Elmhurst, Illinois 60126-1196 www.liftmaster.com Mega ARM Tower Models: MADCBB, MATDCBB, MASDCBB & MASTDCBB (MEGA ARM, MEGA ARM TOWER, MEGA SPRINT & MEGA SPRINT TOWER) 1/2 HP COMMERCIAL DUTY PARKING GATE OPERATOR INSTALLATION AND SERVICE MANUAL IMPORTANT: Read and understand Warranty Page first. Batteries (included) MUST be connected for proper operation of unit.
Use (2) LiftMaster 12Vdc 7AH (Part # MBAT). Radio Receiver Included The Chamberlain Group, Inc. 845 Larch Avenue Elmhurst, Illinois 60126-1196 www.liftmaster.com Mega ARM Tower Models: MADCBB, MATDCBB, MASDCBB & MASTDCBB (MEGA ARM, MEGA ARM TOWER, MEGA SPRINT & MEGA SPRINT TOWER) 1/2 HP COMMERCIAL DUTY PARKING GATE OPERATOR INSTALLATION AND SERVICE MANUAL IMPORTANT: Read and understand Warranty Page first. Batteries (included) MUST be connected for proper operation of unit.
MATDCBB Green Control Board V.6.4 or newer Manual
Page 2
... ACCESS MANAGEMENT SYSTEM (SAMS) SAMS With Other Operators 17 SAMS Two Mega Arms with "Memory 17 CONTROL BOARD LAYOUT Input Locations 18 MEGA ARM UL PARTS LIST Part Numbers and Descriptions 19 Parts Shipped 19 Mega Arm Tower Unique Parts List 19 Mega Arm Options Parts List 19 ACCESSORIES 20 OPERATOR NOTES 21-22 WARRANTY...
... ACCESS MANAGEMENT SYSTEM (SAMS) SAMS With Other Operators 17 SAMS Two Mega Arms with "Memory 17 CONTROL BOARD LAYOUT Input Locations 18 MEGA ARM UL PARTS LIST Part Numbers and Descriptions 19 Parts Shipped 19 Mega Arm Tower Unique Parts List 19 Mega Arm Options Parts List 19 ACCESSORIES 20 OPERATOR NOTES 21-22 WARRANTY...
MATDCBB Green Control Board V.6.4 or newer Manual
Page 3
... Phillips Head Screwdriver • C Clamps • Level • Small Screwdriver • T25 Torx Head Screwdriver AVERTISSEMENT UNIT OVERVIEAAWAVVTEETRRETTNIISSTSSIOEENMMEENNTT The LiftMaster model MEGA ARM barrier style parking gate operator is sensed. uses magnetic (Hall Effect) sensors to monitor arm position. • Maximum Run Timer ... page. 3 AVERTISSEMENT AVERTISSEMENT • Molded Polyethylene UV stabilized cover never needs wax or paint (excludes towers). Refer to trigger a warning device PARDEVCEARUTCEIÓNCNIA when tail-gating is unique in the industry.
... Phillips Head Screwdriver • C Clamps • Level • Small Screwdriver • T25 Torx Head Screwdriver AVERTISSEMENT UNIT OVERVIEAAWAVVTEETRRETTNIISSTSSIOEENMMEENNTT The LiftMaster model MEGA ARM barrier style parking gate operator is sensed. uses magnetic (Hall Effect) sensors to monitor arm position. • Maximum Run Timer ... page. 3 AVERTISSEMENT AVERTISSEMENT • Molded Polyethylene UV stabilized cover never needs wax or paint (excludes towers). Refer to trigger a warning device PARDEVCEARUTCEIÓNCNIA when tail-gating is unique in the industry.
MATDCBB Green Control Board V.6.4 or newer Manual
Page 4
... UL325 for use in both sides of motorized gate systems. Moving Gate Can Cause Injury or Death KEEP CLEAR! SAFETY ACCESSORY SELECTION All UL325 compliant LiftMaster gate operators will accept external entrapment protection devices to warn pedestrians of the dangers of the gate to protect people from motorized gate systems. UL325...
... UL325 for use in both sides of motorized gate systems. Moving Gate Can Cause Injury or Death KEEP CLEAR! SAFETY ACCESSORY SELECTION All UL325 compliant LiftMaster gate operators will accept external entrapment protection devices to warn pedestrians of the dangers of the gate to protect people from motorized gate systems. UL325...
MATDCBB Green Control Board V.6.4 or newer Manual
Page 5
Each gate system is only one component. Install the gate operator only when: a. Pedestrians must be installed in a location so that the gate covers in its function as the bystander. A minimum of two (2) WARNING SIGNS shall be located at the bottom edge of non-contact sensor for Exposed Rollers • Vertical Posts • Photoelectric Sensors • Instructional and Precautionary Signage 4. Reference owner's manual regarding placement of a vertical barrier (arm). 5 One or more contact sensors shall be installed, one or more non-contact sensors shall ...
Each gate system is only one component. Install the gate operator only when: a. Pedestrians must be installed in a location so that the gate covers in its function as the bystander. A minimum of two (2) WARNING SIGNS shall be located at the bottom edge of non-contact sensor for Exposed Rollers • Vertical Posts • Photoelectric Sensors • Instructional and Precautionary Signage 4. Reference owner's manual regarding placement of a vertical barrier (arm). 5 One or more contact sensors shall be installed, one or more non-contact sensors shall ...
MATDCBB Green Control Board V.6.4 or newer Manual
Page 6
... 36-1/2" 5" 4" 8" 17-1/2" 9" Pad (24"x24") 12" 8" 5-1/2" 2" Center Line These Dimensions Will Center the Operator on the Pad 3-1/2" 3-1/2" Inside Post 5-1/2" 8" 9" TOWER CABINET DIMENSIONS 12" Pedestal Foot Print of Base on Pad 6" 3-1/4" 13-1/2" 3-1/2" Pad (24" x 24" x 24") Gate Arm Bracket 7-1/8" 7-1/8" 3-1/2" 42" 10-1/4" 42"... 36-1/2" 9-7/8" 8-1/4" Open Area In Base For Conduit 13-1/2" 14-1/4" 13-1/2" Side View 12-1/4" Door 14-1/4" Tower Foot Print of Base on drive way side (in order to get the most reach out of the unit. See accessory page for ...
... 36-1/2" 5" 4" 8" 17-1/2" 9" Pad (24"x24") 12" 8" 5-1/2" 2" Center Line These Dimensions Will Center the Operator on the Pad 3-1/2" 3-1/2" Inside Post 5-1/2" 8" 9" TOWER CABINET DIMENSIONS 12" Pedestal Foot Print of Base on Pad 6" 3-1/4" 13-1/2" 3-1/2" Pad (24" x 24" x 24") Gate Arm Bracket 7-1/8" 7-1/8" 3-1/2" 42" 10-1/4" 42"... 36-1/2" 9-7/8" 8-1/4" Open Area In Base For Conduit 13-1/2" 14-1/4" 13-1/2" Side View 12-1/4" Door 14-1/4" Tower Foot Print of Base on drive way side (in order to get the most reach out of the unit. See accessory page for ...
MATDCBB Green Control Board V.6.4 or newer Manual
Page 7
... End of 4"x4" Tube 230 Vac 120 Vac Please purchase the 120 to the ground. INPUT COMMANDS CONNECTIONS Use common and normally open with the MEGA ARM. Make for the desired operation, see page 18. 9, 10, 11,12 - SAMS with a vehicle detector, it was closing and a tailgater is used with memory...
... End of 4"x4" Tube 230 Vac 120 Vac Please purchase the 120 to the ground. INPUT COMMANDS CONNECTIONS Use common and normally open with the MEGA ARM. Make for the desired operation, see page 18. 9, 10, 11,12 - SAMS with a vehicle detector, it was closing and a tailgater is used with memory...
MATDCBB Green Control Board V.6.4 or newer Manual
Page 8
... connection from chassis to chassis (or from the operator to the (BLACK -) terminal of each battery if one is not already in place (Figure 1). (Use LiftMaster MBAT or 29-NP712 for replacement batteries.) Replace in it (also install vehicle detectors and receivers in pairs. BATTERY INSTALLATION HOOKING UP BATTERY LEADS - RELAY...
... connection from chassis to chassis (or from the operator to the (BLACK -) terminal of each battery if one is not already in place (Figure 1). (Use LiftMaster MBAT or 29-NP712 for replacement batteries.) Replace in it (also install vehicle detectors and receivers in pairs. BATTERY INSTALLATION HOOKING UP BATTERY LEADS - RELAY...
MATDCBB Green Control Board V.6.4 or newer Manual
Page 9
... switch (S3) is adjusted, and that the mechanism travels in the proper 90 degrees desired. REVERSING ARM DIRECTION REVERSING THE DIRECTION OF THE ARM The MEGA ARM allows for mounting in tight places or when it is level with the S3 manual switch making sure that the manual open/close with...
... switch (S3) is adjusted, and that the mechanism travels in the proper 90 degrees desired. REVERSING ARM DIRECTION REVERSING THE DIRECTION OF THE ARM The MEGA ARM allows for mounting in tight places or when it is level with the S3 manual switch making sure that the manual open/close with...
MATDCBB Green Control Board V.6.4 or newer Manual
Page 10
... time. Changing settings will adjust fast run timer by close loop, K1 relay will close by loop, not by timer whenever forced up. On the MEGA ARM the switches 1-5 on (it is reached (activates a swing or slide gate its lane). SWITCH PACK S1 (5-8) SWITCH 5: ON -Will allow the vehicle to close...
... time. Changing settings will adjust fast run timer by close loop, K1 relay will close by loop, not by timer whenever forced up. On the MEGA ARM the switches 1-5 on (it is reached (activates a swing or slide gate its lane). SWITCH PACK S1 (5-8) SWITCH 5: ON -Will allow the vehicle to close...
MATDCBB Green Control Board V.6.4 or newer Manual
Page 11
WIRING THE RECEIVER AVERTISSEMENT Contacts 1 and 2 on the J5 terminal strip at the top of the logic board. Connect terminals 3 and 4 to terminals 1 and 10 on the receiver terminal strip are no obstructions to door travel. • ALWAYS keep gate or garage door in HIGH security mode. The receiver is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this receiver and/or transmitter are for push to open the front panel of receiver case with FCC Standards FOR HOME OR OFFICE USE. Operation is factory set at the HIGH position ...
WIRING THE RECEIVER AVERTISSEMENT Contacts 1 and 2 on the J5 terminal strip at the top of the logic board. Connect terminals 3 and 4 to terminals 1 and 10 on the receiver terminal strip are no obstructions to door travel. • ALWAYS keep gate or garage door in HIGH security mode. The receiver is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this receiver and/or transmitter are for push to open the front panel of receiver case with FCC Standards FOR HOME OR OFFICE USE. Operation is factory set at the HIGH position ...
MATDCBB Green Control Board V.6.4 or newer Manual
Page 12
... object or stop just before the full vertical position. Insert the bolts through the arm and Some slight adjustment either way may be done by a LiftMaster professional. 10. position, time out (using the same delay set at S-2. If gate is opening then the Install arm in . ENTION monthly to gate hardware...
... object or stop just before the full vertical position. Insert the bolts through the arm and Some slight adjustment either way may be done by a LiftMaster professional. 10. position, time out (using the same delay set at S-2. If gate is opening then the Install arm in . ENTION monthly to gate hardware...
MATDCBB Green Control Board V.6.4 or newer Manual
Page 13
... arm if required 9. See the battery manufacturer's Material Safety Data Sheets (01-30839 "MSDS Sheets, Battery, Standard"). LiftMaster does not recommend storage of batteries in the field. Belt loose or needs replacement, adjust with Liftmaster P/N MBAT batteries. Replacement must be 27.5 +0.05, -0 Vdc with batteries disconnected (set with State, Local and Federal...
... arm if required 9. See the battery manufacturer's Material Safety Data Sheets (01-30839 "MSDS Sheets, Battery, Standard"). LiftMaster does not recommend storage of batteries in the field. Belt loose or needs replacement, adjust with Liftmaster P/N MBAT batteries. Replacement must be 27.5 +0.05, -0 Vdc with batteries disconnected (set with State, Local and Federal...
MATDCBB Green Control Board V.6.4 or newer Manual
Page 14
TROUBLESHOOTING WARNING - NOTE: Batteries should be checked when you are sure they still maybe near failure. If LED 12 does not light, then voltage should only be checked as they have had adequate time to open. Replace if blown. No Is the shadow input active? Yes No Is the Safety, Backaway, or Open input active? No Restore AC power and/or turn AC power switch ON. Yes No Is the IRD flashing? The max timer (MRT) has expired. If LED 12 comes ON, batteries are correct. 14 Return of AC power will not operate. GATE NOT OPERATING Gate will clear low battery indicator....
TROUBLESHOOTING WARNING - NOTE: Batteries should be checked when you are sure they still maybe near failure. If LED 12 does not light, then voltage should only be checked as they have had adequate time to open. Replace if blown. No Is the shadow input active? Yes No Is the Safety, Backaway, or Open input active? No Restore AC power and/or turn AC power switch ON. Yes No Is the IRD flashing? The max timer (MRT) has expired. If LED 12 comes ON, batteries are correct. 14 Return of AC power will not operate. GATE NOT OPERATING Gate will clear low battery indicator....
MATDCBB Green Control Board V.6.4 or newer Manual
Page 15
... open or close the gate, use ONLY on a dedicated free exit. Back Away Loop (Free Exit) FIGURE 3 Close Loop Card Reader Tele-entry Radio Control Mega Arm 15 If the vehicle pulls up to the exit loop and then backs away, it will be used to 10'. Terminal #6 is sensed at... Loop (Free Exit) ENTRY WITH ACCESS CONTROL DEVICE Gate will be centered under gate arm. Terminal #6 is to be 4' to open inputs. FIGURE 2 Mega Arm Close Loop Mega Arm Card Reader Tele-entry Radio Control DO NOT ALLOW CONTROL DEVICES TO BE WITHIN 10' OF GATE OR OPERATOR RECOMMENDATION 1: If vehicle detectors...
... open or close the gate, use ONLY on a dedicated free exit. Back Away Loop (Free Exit) FIGURE 3 Close Loop Card Reader Tele-entry Radio Control Mega Arm 15 If the vehicle pulls up to the exit loop and then backs away, it will be used to 10'. Terminal #6 is sensed at... Loop (Free Exit) ENTRY WITH ACCESS CONTROL DEVICE Gate will be centered under gate arm. Terminal #6 is to be 4' to open inputs. FIGURE 2 Mega Arm Close Loop Mega Arm Card Reader Tele-entry Radio Control DO NOT ALLOW CONTROL DEVICES TO BE WITHIN 10' OF GATE OR OPERATOR RECOMMENDATION 1: If vehicle detectors...
MATDCBB Green Control Board V.6.4 or newer Manual
Page 16
... the K1 location ensuring the pins are properly aligned. 2. Connect the Normally open . c. term#12). TRAP INSTRUCTIONS INSTALL THE K1 AUXILIARY RELAY AND CONNECTOR AT MEGA ARM CONNECTED TO THE ACCESS DEVICE 1. TRAP SET UP Interlock C OPEN Trap TES MA S1-6 OFF S1-8 ON C NC NO DC C NC NO DC K1... Trap Close Loop Close Loop ON ON ON ON ON ON ON OFF 12345678 Close Loop Trap S2 Card Reader Tele-entry Radio Control Mega Arm Trap Mega Arm ON ON ON ON ON ON ON OFF OFF 12345678 16 Press the relay into the J1 connector pins. Reconnect the AC Power...
... the K1 location ensuring the pins are properly aligned. 2. Connect the Normally open . c. term#12). TRAP INSTRUCTIONS INSTALL THE K1 AUXILIARY RELAY AND CONNECTOR AT MEGA ARM CONNECTED TO THE ACCESS DEVICE 1. TRAP SET UP Interlock C OPEN Trap TES MA S1-6 OFF S1-8 ON C NC NO DC C NC NO DC K1... Trap Close Loop Close Loop ON ON ON ON ON ON ON OFF 12345678 Close Loop Trap S2 Card Reader Tele-entry Radio Control Mega Arm Trap Mega Arm ON ON ON ON ON ON ON OFF OFF 12345678 16 Press the relay into the J1 connector pins. Reconnect the AC Power...
MATDCBB Green Control Board V.6.4 or newer Manual
Page 17
... operators common and open input. (WARNING: max of dedicated/isolated dry contacts - {C. Connect the K1 relay C and N.O. As long as cause the arm to the MEGA ARM. NOTE: A separate open (or teeth down) the other operator until J5 #1 J5 #1 the arm times out and closes. Tele-Entry NO J5 #8 In ... #11 J5 #8 Other Operator (Slide, Swing, Teeth, etc.) Open Input C Extra Open Limit Switch NC WIRING: Run 2 wires from access control device to the MEGA ARM will in memory) to have ONE gate raised at a time (bottle neck or gates at a cross street). The arm will open the COMMON and...
... operators common and open input. (WARNING: max of dedicated/isolated dry contacts - {C. Connect the K1 relay C and N.O. As long as cause the arm to the MEGA ARM. NOTE: A separate open (or teeth down) the other operator until J5 #1 J5 #1 the arm times out and closes. Tele-Entry NO J5 #8 In ... #11 J5 #8 Other Operator (Slide, Swing, Teeth, etc.) Open Input C Extra Open Limit Switch NC WIRING: Run 2 wires from access control device to the MEGA ARM will in memory) to have ONE gate raised at a time (bottle neck or gates at a cross street). The arm will open the COMMON and...
MATDCBB Green Control Board V.6.4 or newer Manual
Page 18
See diagnostic procedures. Keep in the "Close" position for 24Vdc battery input power. (UL listed fuse only.) 18 F3: 10 amp ATO type fuse for 24Vac input power. (UL listed fuse only.) F4: 15 amp ATO type fuse for normal operation. R13 U19 J4 BAT- BAT- Shows that processor and program are running properly. To allow gate to be opened or closed during service of unit. MOV MOTOR Aux Relay TR J1 C NC NO DC 1 1 B2 + PWR K1 Relay Terminals (Optional) ACC+ ACC- Close Loop Back Away - NOTE: J5 #8 is 24Vdc regulated rated at 500 ma. [1/2 amp]. Reader, Push Button...
See diagnostic procedures. Keep in the "Close" position for 24Vdc battery input power. (UL listed fuse only.) 18 F3: 10 amp ATO type fuse for 24Vac input power. (UL listed fuse only.) F4: 15 amp ATO type fuse for normal operation. R13 U19 J4 BAT- BAT- Shows that processor and program are running properly. To allow gate to be opened or closed during service of unit. MOV MOTOR Aux Relay TR J1 C NC NO DC 1 1 B2 + PWR K1 Relay Terminals (Optional) ACC+ ACC- Close Loop Back Away - NOTE: J5 #8 is 24Vdc regulated rated at 500 ma. [1/2 amp]. Reader, Push Button...
MATDCBB Green Control Board V.6.4 or newer Manual
Page 19
... Motor Transformer 120 Vac Duplex Outlet (120 Vac Only) Bolt and Nut (4) Reducer On/Off Switch Unit Cover for Mega Arm (Not Tower) Nylon Arm Nuts (2) Arm Bolts (2) Gate Arm - 12' Filter Module Surge Suppressor Collar Nylon Washer PARTS SHIPPED ITEM... Nylon Nuts 7AH Batteries MEGA ARM TOWER UNIQUE PARTS LIST QTY ITEM PART NUMBER DESCRIPTION 1 * MA020T Unit Cover for Mega Arm Tower 1 * MA020D Unit Door for Mega Arm Tower 1 1 MEGA ARM OPTIONS PARTS LIST 2 ITEM PART NUMBER DESCRIPTION 10 * 71-TRAP Trap option 2 * 71-SPRINT Sprint option * 71-TRAPSP Sprint Trap option 19
... Motor Transformer 120 Vac Duplex Outlet (120 Vac Only) Bolt and Nut (4) Reducer On/Off Switch Unit Cover for Mega Arm (Not Tower) Nylon Arm Nuts (2) Arm Bolts (2) Gate Arm - 12' Filter Module Surge Suppressor Collar Nylon Washer PARTS SHIPPED ITEM... Nylon Nuts 7AH Batteries MEGA ARM TOWER UNIQUE PARTS LIST QTY ITEM PART NUMBER DESCRIPTION 1 * MA020T Unit Cover for Mega Arm Tower 1 * MA020D Unit Door for Mega Arm Tower 1 1 MEGA ARM OPTIONS PARTS LIST 2 ITEM PART NUMBER DESCRIPTION 10 * 71-TRAP Trap option 2 * 71-SPRINT Sprint option * 71-TRAPSP Sprint Trap option 19
MATDCBB Green Control Board V.6.4 or newer Manual
Page 20
...black stripes (requires MA117). of 50), thin. of 50). Replacement Pad: 14' x 4", yellow. K1 Relay Output Option Sprint Units Only: SP8 SP8 TUBE SP8 PAD Sprint Gate Arm: 8' Padded Safety Arm, yellow. Articulating PVC (folding) Arm: 9' with yellow/black stripes. Articulation Aluminum (folding...clip. Nylon Arm Nuts: (Pkg. Round Padded Arm: 12' x 4" diameter, yellow (requires MA031). Slip Clutch Option: For Mega Arm Gear Box. Hardware Kit: (Only for MA034). Includes required relay and limits. Includes surge suppressor, wire jumper, duplex box covers ...
...black stripes (requires MA117). of 50), thin. of 50). Replacement Pad: 14' x 4", yellow. K1 Relay Output Option Sprint Units Only: SP8 SP8 TUBE SP8 PAD Sprint Gate Arm: 8' Padded Safety Arm, yellow. Articulating PVC (folding) Arm: 9' with yellow/black stripes. Articulation Aluminum (folding...clip. Nylon Arm Nuts: (Pkg. Round Padded Arm: 12' x 4" diameter, yellow (requires MA031). Slip Clutch Option: For Mega Arm Gear Box. Hardware Kit: (Only for MA034). Includes required relay and limits. Includes surge suppressor, wire jumper, duplex box covers ...