LJ8900W Manual English French
Page 1
Register your door operator to receive updates and offers from LiftMaster SM Take a photo of door operation per hour. This product is not intended for Sectional Doors Model LJ8900W For Light Duty Commercial Use Install On Sectional Doors With Torsion Assemblies Only NOT FOR RESIDENTIAL... USE After Installation, Please Leave with outside pickup drum or doors utilizing extension springs. • Please read this manual and the enclosed safety ...
Register your door operator to receive updates and offers from LiftMaster SM Take a photo of door operation per hour. This product is not intended for Sectional Doors Model LJ8900W For Light Duty Commercial Use Install On Sectional Doors With Torsion Assemblies Only NOT FOR RESIDENTIAL... USE After Installation, Please Leave with outside pickup drum or doors utilizing extension springs. • Please read this manual and the enclosed safety ...
LJ8900W Manual English French
Page 2
...the Safety Reversal System 20 Test the Protector System 20 Test Cable Tension Monitor 21 Test Automatic door lock 21 To Open the Door Manually 21 Operation 22 Using Your Door Operator 23 Programming 24 Remote Control (Not Provided 24 To Erase the Memory 24 Maintenance 25 Care...Safety Symbols and Signal Words on the following pages, they will alert you do not comply with the instructions and warnings contained in this manual. For more information go to cause cancer or birth defects or other reproductive harm. The hazard may come from something mechanical or from...
...the Safety Reversal System 20 Test the Protector System 20 Test Cable Tension Monitor 21 Test Automatic door lock 21 To Open the Door Manually 21 Operation 22 Using Your Door Operator 23 Programming 24 Remote Control (Not Provided 24 To Erase the Memory 24 Maintenance 25 Care...Safety Symbols and Signal Words on the following pages, they will alert you do not comply with the instructions and warnings contained in this manual. For more information go to cause cancer or birth defects or other reproductive harm. The hazard may come from something mechanical or from...
LJ8900W Manual English French
Page 5
... flex cable adapter: Required for permanent wiring. Automatic door lock (Model 841LM): The automatic door lock is used to prevent the door from being manually opened once the door is missing, carefully check the packing material. If anything is fully closed. 5 Single Button Control Station Door Operator 2 Conductor Bell Wire...
... flex cable adapter: Required for permanent wiring. Automatic door lock (Model 841LM): The automatic door lock is used to prevent the door from being manually opened once the door is missing, carefully check the packing material. If anything is fully closed. 5 Single Button Control Station Door Operator 2 Conductor Bell Wire...
LJ8900W Manual English French
Page 9
... of the emergency release rope through the handle. Mount the emergency release within 6 10 ft. (3.05 m) of the door operator. 6. The third roller from being manually opened once the door is clear of a door roller. 3. NOTE: If it is ideal for most installations. 2. NOTE: Older model 24 V door locks are incompatible...
... of the emergency release rope through the handle. Mount the emergency release within 6 10 ft. (3.05 m) of the door operator. 6. The third roller from being manually opened once the door is clear of a door roller. 3. NOTE: If it is ideal for most installations. 2. NOTE: Older model 24 V door locks are incompatible...
LJ8900W Manual English French
Page 21
... 2. Pull the emergency handle a second time. 5. To prevent possible SERIOUS INJURY or DEATH from the door operator and lift the door manually. If there is CLOSED. With the door fully closed, the automatic door lock bolt should move . 3. When the door reaches the fully...The door will flash diagnostic code 3-5, see page 26. Emergency Release Handle 21 The automatic door lock should be manually released by sliding the manual release handle to the door operator, pull the emergency release handle straight down direction. TEST THE EMERGENCY RELEASE: 1. Return ...
... 2. Pull the emergency handle a second time. 5. To prevent possible SERIOUS INJURY or DEATH from the door operator and lift the door manually. If there is CLOSED. With the door fully closed, the automatic door lock bolt should move . 3. When the door reaches the fully...The door will flash diagnostic code 3-5, see page 26. Emergency Release Handle 21 The automatic door lock should be manually released by sliding the manual release handle to the door operator, pull the emergency release handle straight down direction. TEST THE EMERGENCY RELEASE: 1. Return ...
LJ8900W Manual English French
Page 25
... reverse test. These limits are designed to radio communications. NOTICE: This device complies with Part 15 of Your Door Operator MAINTENANCE SCHEDULE Once a Month • Manually operate door. Adjust limits if necessary (see Adjustment Step 2). Maintenance Care of the FCC rules and Industry Canada's license-exempt RSSs.
... reverse test. These limits are designed to radio communications. NOTICE: This device complies with Part 15 of Your Door Operator MAINTENANCE SCHEDULE Once a Month • Manually operate door. Adjust limits if necessary (see Adjustment Step 2). Maintenance Care of the FCC rules and Industry Canada's license-exempt RSSs.
LJ8900W Manual English French
Page 26
...not flickering. Inspect sensor wire at travel to coasting position or have door balanced by a trained technician. 2 1-5 No movement or sound. Manually open and close the door. Replace motor if necessary. Check for a disconnected or cut . as a broken spring or door lock, correct as ... door operator will not close the door. Make sure nothing is faulty. Activate the door operator again. No movement, only a single click. Manually open and close the door. Check for binding or obstructions, such as a broken spring or door lock, correct as needed . Battery backup...
...not flickering. Inspect sensor wire at travel to coasting position or have door balanced by a trained technician. 2 1-5 No movement or sound. Manually open and close the door. Replace motor if necessary. Check for a disconnected or cut . as a broken spring or door lock, correct as ... door operator will not close the door. Make sure nothing is faulty. Activate the door operator again. No movement, only a single click. Manually open and close the door. Check for binding or obstructions, such as a broken spring or door lock, correct as needed . Battery backup...
LJ8900W Manual English French
Page 27
...remote controls. Pull the emergency release handle. Operate the door manually. If it is unbalanced or binding, call a trained door systems technician. If it replaced (see page 17). Repeat with the remote control or visit LiftMaster.com). If a second cable tension monitor has been removed,... follow the instructions to close the door manually. The door reverses for reference). Close the door and use the emergency release handle...
...remote controls. Pull the emergency release handle. Operate the door manually. If it is unbalanced or binding, call a trained door systems technician. If it replaced (see page 17). Repeat with the remote control or visit LiftMaster.com). If a second cable tension monitor has been removed,... follow the instructions to close the door manually. The door reverses for reference). Close the door and use the emergency release handle...
LJ8900W Manual English French
Page 28
...; Collar not tightened securely. If it rotates. • Check that the door operator is mounted at a right angle to be opened and closed manually. When power is restored, pull manual release a second time. • When in operation: • Some minor movement is normal for 30 hours or up and down as it...
...; Collar not tightened securely. If it rotates. • Check that the door operator is mounted at a right angle to be opened and closed manually. When power is restored, pull manual release a second time. • When in operation: • Some minor movement is normal for 30 hours or up and down as it...
LJ8900W Manual English French
Page 29
... Cover 29 DESCRIPTION 1 050DCJCWFSD Logic Board 2 041D8861 Travel Module with 2-conductor bell wire attached DESCRIPTION Mounting bracket Safety reversing sensor brackets (2) Collar NOT SHOWN Owner's manual Door Operator Parts 2 1 6 5 3 4 KEY PART NO.
... Cover 29 DESCRIPTION 1 050DCJCWFSD Logic Board 2 041D8861 Travel Module with 2-conductor bell wire attached DESCRIPTION Mounting bracket Safety reversing sensor brackets (2) Collar NOT SHOWN Owner's manual Door Operator Parts 2 1 6 5 3 4 KEY PART NO.
LJ8900W Manual English French
Page 30
...or the normal mounting area is obstructed. 841LM Automatic Door Lock: The automatic door lock is used to prevent the door from being manually opened once the door is a registered trademark of invisible light beams for 30 hours of Google Inc. myQ Accessories 827LM myQ LED ...door operator. Drexel Rd., Suite #180 Tucson, AZ 85706 For installation and service information call: 1-800-528-9131 Or visit us online at: LiftMaster.com Before calling, please have access to the door operator or a remote control. STANDARD Accessories 891LM Single Button Security+ 2.0 Remote Control: Includes ...
...or the normal mounting area is obstructed. 841LM Automatic Door Lock: The automatic door lock is used to prevent the door from being manually opened once the door is a registered trademark of invisible light beams for 30 hours of Google Inc. myQ Accessories 827LM myQ LED ...door operator. Drexel Rd., Suite #180 Tucson, AZ 85706 For installation and service information call: 1-800-528-9131 Or visit us online at: LiftMaster.com Before calling, please have access to the door operator or a remote control. STANDARD Accessories 891LM Single Button Security+ 2.0 Remote Control: Includes ...
LJ8900W Product Data Sheet
Page 1
LJ8900W LIGHT-DUTY COMMERCIAL JACKSHAFT DOOR OPERATOR ... 180 square feet INTERNET CONNECTIVITY myQ® Technology enables remote monitoring and control of the operators installation manual to meet UL 325 requirements. ***Operator directly connects via a smartphone, tablet, or computer*** This ...INSTALLATION FEATURES UNIVERSAL MOUNTING Yes, can be equipped with an external monitored entrapment protection device. Use only LiftMaster monitored entrapment protection devices itemized on -board with light-duty cycle requirements RATED DUTY CYCLE Light-duty...
LJ8900W LIGHT-DUTY COMMERCIAL JACKSHAFT DOOR OPERATOR ... 180 square feet INTERNET CONNECTIVITY myQ® Technology enables remote monitoring and control of the operators installation manual to meet UL 325 requirements. ***Operator directly connects via a smartphone, tablet, or computer*** This ...INSTALLATION FEATURES UNIVERSAL MOUNTING Yes, can be equipped with an external monitored entrapment protection device. Use only LiftMaster monitored entrapment protection devices itemized on -board with light-duty cycle requirements RATED DUTY CYCLE Light-duty...
Instructions - English French Spanish
Page 1
... touch printed circuit board of the clevis pin, remove chain from the receiver logic board (E). 7. Route the antenna through the cover (G). 13. Refer to your manual to the chassis (G). Remove the four screws securing the cover to reset your travel and force settings. 1 G H A 3. NOTE: If there is on the green wire...
... touch printed circuit board of the clevis pin, remove chain from the receiver logic board (E). 7. Route the antenna through the cover (G). 13. Refer to your manual to the chassis (G). Remove the four screws securing the cover to reset your travel and force settings. 1 G H A 3. NOTE: If there is on the green wire...
Light-Duty Operator Brochure
Page 2
... operator when the power's out to manage, the last thing you 're away. 100% 2-Year Warranty Anywhere Assurance Always know that consistent manual operation can get the job done safely. SMART LIGHTING MyQ® Remote LED Light 827LM Can be scheduled to your business safe and secure with... the LJ8900W only. An approved safety solution, tested by UL®. Keep your business. INCREASED SECURITY Automatic Door Lock 841LM Deadbolts the sectional door every...
... operator when the power's out to manage, the last thing you 're away. 100% 2-Year Warranty Anywhere Assurance Always know that consistent manual operation can get the job done safely. SMART LIGHTING MyQ® Remote LED Light 827LM Can be scheduled to your business safe and secure with... the LJ8900W only. An approved safety solution, tested by UL®. Keep your business. INCREASED SECURITY Automatic Door Lock 841LM Deadbolts the sectional door every...