Installation Manual
Page 1
... Class I, II, and III vehicular swing gate applications. • Visit LiftMaster.com to 71403. LA400PKGULTECH LiftMaster 300 Windsor Drive Oak Brook, IL 60523 Take a photo of the camera icon including the points ( ). 2. Access installation and technical support guides or register this product 1. Model LA400UL RESIDENTIAL DC VEHICULAR SWING GATE OPERATOR INSTALLATION MANUAL LA400PKGUL Single...
... Class I, II, and III vehicular swing gate applications. • Visit LiftMaster.com to 71403. LA400PKGULTECH LiftMaster 300 Windsor Drive Oak Brook, IL 60523 Take a photo of the camera icon including the points ( ). 2. Access installation and technical support guides or register this product 1. Model LA400UL RESIDENTIAL DC VEHICULAR SWING GATE OPERATOR INSTALLATION MANUAL LA400PKGUL Single...
Installation Manual
Page 6
...16"-18 x 1-1/2" (1) Keylock Cap Hex Bolt 3/8"-16 x 1-1/2" (1) Hex Nut 3/8"-16 (3) Carriage Bolt 3/8" x 5-15/16" (2) Optional Accessories Push-to-Open Bracket (Model 50-19503) If your application requires the gate to be pushed open, a push-to-open bracket is required, see Accessories. 6 Key (2) Pin (2) Flat Washer 3/8" (3)... NOTE: Hardware quantities shown below are doubled for LA412DC. Quantities are for LA412DCS. Expansion Board (Model K1D8387-1CC) Large Metal Control Box for Solar Applications (Model XLSOLARCONTUL) Required for solar installations (batteries not included).
...16"-18 x 1-1/2" (1) Keylock Cap Hex Bolt 3/8"-16 x 1-1/2" (1) Hex Nut 3/8"-16 (3) Carriage Bolt 3/8" x 5-15/16" (2) Optional Accessories Push-to-Open Bracket (Model 50-19503) If your application requires the gate to be pushed open, a push-to-open bracket is required, see Accessories. 6 Key (2) Pin (2) Flat Washer 3/8" (3)... NOTE: Hardware quantities shown below are doubled for LA412DC. Quantities are for LA412DCS. Expansion Board (Model K1D8387-1CC) Large Metal Control Box for Solar Applications (Model XLSOLARCONTUL) Required for solar installations (batteries not included).
Installation Manual
Page 7
... including Accessory Outlets) 24 Vdc Battery Run / Direct Plug-in Transformer Charge 24 Vdc, 500mA max. up to 4 edge sensors using wireless edge sensor kit model LMWEKITU. *Travel time and range are affected by A and B mounting dimensions, see INSTALLATION. 7 up to 3 entrapment protection devices configurable to either close or open direction...
... including Accessory Outlets) 24 Vdc Battery Run / Direct Plug-in Transformer Charge 24 Vdc, 500mA max. up to 4 edge sensors using wireless edge sensor kit model LMWEKITU. *Travel time and range are affected by A and B mounting dimensions, see INSTALLATION. 7 up to 3 entrapment protection devices configurable to either close or open direction...
Installation Manual
Page 42
... Application Requirements 33AH Battery Requirements: l Large Metal Control Box for Solar Applications (Model LA400CONTUL) l A minimum of two 10W solar panels in series (Model SP10W12V) l A maximum of six 10W solar panels (Model SP10W12V). l Two 7AH batteries (29-NP712) l Solar Battery Harness (Model K94-37236) Solar Zones Solar panel recommendations are approximations. Ratings vary based on...
... Application Requirements 33AH Battery Requirements: l Large Metal Control Box for Solar Applications (Model LA400CONTUL) l A minimum of two 10W solar panels in series (Model SP10W12V) l A maximum of six 10W solar panels (Model SP10W12V). l Two 7AH batteries (29-NP712) l Solar Battery Harness (Model K94-37236) Solar Zones Solar panel recommendations are approximations. Ratings vary based on...
Installation Manual
Page 43
APPENDIX Solar usage guide Typical System Standby Battery Current Consumption (mA) System voltage Main board with no radios programmed One or more LiftMaster® remote controls programmed myQ® device or wireless dual gate programmed Expansion board Per loop detector LOOPDETLM (up to 3 loop detectors... in to the expansion board) Add up current draw by feature and accessory to determine total current draw NOTE: The use of photoelectric sensor heaters (models LMRRUL and LMTBUL) is NOT recommended in solar applications. 24V 2.7 mA +1 mA +2.4 mA +11.1 mA +3.8 mA 10W SOLAR PANEL (Must use ...
APPENDIX Solar usage guide Typical System Standby Battery Current Consumption (mA) System voltage Main board with no radios programmed One or more LiftMaster® remote controls programmed myQ® device or wireless dual gate programmed Expansion board Per loop detector LOOPDETLM (up to 3 loop detectors... in to the expansion board) Add up current draw by feature and accessory to determine total current draw NOTE: The use of photoelectric sensor heaters (models LMRRUL and LMTBUL) is NOT recommended in solar applications. 24V 2.7 mA +1 mA +2.4 mA +11.1 mA +3.8 mA 10W SOLAR PANEL (Must use ...
Installation Manual
Page 45
Wire the solar panels 45 APPENDIX Wire the Batteries Solar panel applications require the Solar Harness Kit model K94-37236 (see Accessories).
Wire the solar panels 45 APPENDIX Wire the Batteries Solar panel applications require the Solar Harness Kit model K94-37236 (see Accessories).
Installation Manual
Page 49
... or key chain. ACCESSORIES Entrapment Protection LiftMaster monitored through beam photoelectric sensor Models LMTBUL and LMTBU LiftMaster monitored retro-reflective photoelectric sensor Models LMRRUL and LMRRU LiftMaster Monitered Commercial Protector System® Models CPS-UN4 and CPSUN4G LiftMaster monitored wireless edge kit (transmitter and receiver) Model LMWEKITU LiftMaster monitored wireless edge transmitter Model LMWETXU Large profile monitored edge (82 ft...
... or key chain. ACCESSORIES Entrapment Protection LiftMaster monitored through beam photoelectric sensor Models LMTBUL and LMTBU LiftMaster monitored retro-reflective photoelectric sensor Models LMRRUL and LMRRU LiftMaster Monitered Commercial Protector System® Models CPS-UN4 and CPSUN4G LiftMaster monitored wireless edge kit (transmitter and receiver) Model LMWEKITU LiftMaster monitored wireless edge transmitter Model LMWETXU Large profile monitored edge (82 ft...
Installation Manual
Page 50
...Must be remotely installed. Reuse existing harnesses. For use with operator. Model K10-36183 Universal solar wire harness kit For 7AH and 33AH applications. Model 86LM LiftMaster Cloud™ connected access protocol - Models SP10W12V (10 Watt, 12V) and SP20W12V (20 Watt, 12V) Plug... This kit is buried in loop detector Low power. Model 50-19503 Magnetic gate lock Outdoor magnetic lock, transformer, junction box, mounting plate and hardware. LiftMaster low power accessory. Model MG1300 Transformer Model APOW3 Wireless commercial keypad Durable wireless keypad with Large Metal...
...Must be remotely installed. Reuse existing harnesses. For use with operator. Model K10-36183 Universal solar wire harness kit For 7AH and 33AH applications. Model 86LM LiftMaster Cloud™ connected access protocol - Models SP10W12V (10 Watt, 12V) and SP20W12V (20 Watt, 12V) Plug... This kit is buried in loop detector Low power. Model 50-19503 Magnetic gate lock Outdoor magnetic lock, transformer, junction box, mounting plate and hardware. LiftMaster low power accessory. Model MG1300 Transformer Model APOW3 Wireless commercial keypad Durable wireless keypad with Large Metal...
LA400UL Wiring Diagram
Page 1
... system. TO SCROLL THROUGH THE SAVED CODES: Press the OPEN button to cycle to run the system. CODE COLOR KEY: LiftMaster System External Entrapment Protection Installed System Inherent Entrapment Protection Informational CODE MEANING SOLUTION Main control board has experienced an internal Disconnect all ...Edge Sensor for power. If not, disconnect all power, wait 15 seconds, then 31 failure. If limits are monitored. WIRING DIAGRAM Model LA400UL CONTROLS To reduce the risk of INJURY or DEATH: • DISCONNECT power and battery BEFORE installing or servicing operator. •...
... system. TO SCROLL THROUGH THE SAVED CODES: Press the OPEN button to cycle to run the system. CODE COLOR KEY: LiftMaster System External Entrapment Protection Installed System Inherent Entrapment Protection Informational CODE MEANING SOLUTION Main control board has experienced an internal Disconnect all ...Edge Sensor for power. If not, disconnect all power, wait 15 seconds, then 31 failure. If limits are monitored. WIRING DIAGRAM Model LA400UL CONTROLS To reduce the risk of INJURY or DEATH: • DISCONNECT power and battery BEFORE installing or servicing operator. •...
LA400PKGUL Product Guide - English
Page 2
... CLOSE -Closes the Gate Immediately After a Vehicle Pulls Off the Interrupt Loop ANTI-TAILGATE -Prevents Unauthorized Access *May require an external adapter depending on the model and year of Wi-Fi Alliance © 2019 Bluetooth SIG, Inc. SYNCHRONIZED CLOSE - -S i mul t a n e o u s l y C l o s e s G a t es MONITORED SAFETY INPUTS - -3 M a i n B ...to 140°F (60°C) GATE TRAVEL SPEED Opens 90° in 15-17 Seconds STANDARD FEATURES. LiftMaster, the LiftMaster logo, myQ and the myQ logo are registered trademarks of The Chamberlain Group, Inc. 300 Windsor Drive, Oak Brook, IL ...
... CLOSE -Closes the Gate Immediately After a Vehicle Pulls Off the Interrupt Loop ANTI-TAILGATE -Prevents Unauthorized Access *May require an external adapter depending on the model and year of Wi-Fi Alliance © 2019 Bluetooth SIG, Inc. SYNCHRONIZED CLOSE - -S i mul t a n e o u s l y C l o s e s G a t es MONITORED SAFETY INPUTS - -3 M a i n B ...to 140°F (60°C) GATE TRAVEL SPEED Opens 90° in 15-17 Seconds STANDARD FEATURES. LiftMaster, the LiftMaster logo, myQ and the myQ logo are registered trademarks of The Chamberlain Group, Inc. 300 Windsor Drive, Oak Brook, IL ...
Gate Operator Feature Chart
Page 1
...7 Years Res. 5 Years Comm. 18 ft. 1600 lbs. rails. 600 cycles on all our products, visit LiftMaster.com/TOTALPAS UL 325 LISTED GATE OPERATOR FEATURE CHART LMGTCTOOSB High-Cycle, High-Temperature Continuous Duty 115V Single Phase Yes Yes... - - High-Cycle, High-Temperature Continuous Duty 1000 lbs. Note: LMRRUL/LMTBUL Heater option not recommended for Battery Backup. Model Number LA500PKGUL RESIDENTIAL GATE OPERATORS LA400PKGUL LA412PKGUL Description 24VDC Residential/Light Commercial Linear Actuator 24VDC Residential Linear Actuator 12VDC Solar Residential Linear ...
...7 Years Res. 5 Years Comm. 18 ft. 1600 lbs. rails. 600 cycles on all our products, visit LiftMaster.com/TOTALPAS UL 325 LISTED GATE OPERATOR FEATURE CHART LMGTCTOOSB High-Cycle, High-Temperature Continuous Duty 115V Single Phase Yes Yes... - - High-Cycle, High-Temperature Continuous Duty 1000 lbs. Note: LMRRUL/LMTBUL Heater option not recommended for Battery Backup. Model Number LA500PKGUL RESIDENTIAL GATE OPERATORS LA400PKGUL LA412PKGUL Description 24VDC Residential/Light Commercial Linear Actuator 24VDC Residential Linear Actuator 12VDC Solar Residential Linear ...
Traffic Systems Product Line Catalog
Page 4
... advanced features and state-of-the-art equipment, including our new and improved spike design. H O W TO O R D E R 1 | CHOOSE A MODEL 2 | SELECT A FINISH 1 13 0 0 1 1300 P POWDER P COATED RED 4 CORROSION C* RESISTANT* RED END E BEVEL RED 3 | ORDER To place your LiftMaster® Sales Representative The curved teeth help ensure safe and efficient traffic flow and improved protection.
... advanced features and state-of-the-art equipment, including our new and improved spike design. H O W TO O R D E R 1 | CHOOSE A MODEL 2 | SELECT A FINISH 1 13 0 0 1 1300 P POWDER P COATED RED 4 CORROSION C* RESISTANT* RED END E BEVEL RED 3 | ORDER To place your LiftMaster® Sales Representative The curved teeth help ensure safe and efficient traffic flow and improved protection.
Traffic Systems Product Line Catalog
Page 10
...OW TO O R D E R 1 | CHOOSE A MODEL MT S 2 | SELECT AN ORIENTATION MT S L 3 | A D D A F I N I Z E D TRAFFIC AND PARKING S Y S T E M S Total traffic control solution. Surface mount (MTS) shown. L i f t M a s t e r. c o m L i f t M a s t e r. c o m Call 800.323.2276 Contact your order visit: Email Customer.Service@ D e a l e r. LiftMaster's® fully integrated operator, barrier and spike system, available...R I S H IF NEEDED MT S L 4 | SELECT A LENGTH M T S L C 12 10 L LEFT R RIGHT 5 | ORDER C* CORROSION RESISTANT* RED To place your LiftMaster® Sales Representative
...OW TO O R D E R 1 | CHOOSE A MODEL MT S 2 | SELECT AN ORIENTATION MT S L 3 | A D D A F I N I Z E D TRAFFIC AND PARKING S Y S T E M S Total traffic control solution. Surface mount (MTS) shown. L i f t M a s t e r. c o m L i f t M a s t e r. c o m Call 800.323.2276 Contact your order visit: Email Customer.Service@ D e a l e r. LiftMaster's® fully integrated operator, barrier and spike system, available...R I S H IF NEEDED MT S L 4 | SELECT A LENGTH M T S L C 12 10 L LEFT R RIGHT 5 | ORDER C* CORROSION RESISTANT* RED To place your LiftMaster® Sales Representative
Traffic Systems Product Line Catalog
Page 20
... | 800.323.2276 Email Customer.Service@LiftMaster.com Contact Your LiftMaster Sales Representative © 2019 LiftMaster All Rights Reserved 300 Windsor Drive, Oak Brook, IL 60523 LiftMaster.com LMGTENBROOTS 6/19 H O W TO O R D E R 1 | CHOOSE A MODEL 12300 2 | SELECT A FINISH 12300 P P POWDER COATED RED C* CORROSION RESISTANT RED* Most Traffic and Parking Systems are available in several finishes. When applicable...
... | 800.323.2276 Email Customer.Service@LiftMaster.com Contact Your LiftMaster Sales Representative © 2019 LiftMaster All Rights Reserved 300 Windsor Drive, Oak Brook, IL 60523 LiftMaster.com LMGTENBROOTS 6/19 H O W TO O R D E R 1 | CHOOSE A MODEL 12300 2 | SELECT A FINISH 12300 P P POWDER COATED RED C* CORROSION RESISTANT RED* Most Traffic and Parking Systems are available in several finishes. When applicable...
Solar Tax Credit Letter
Page 2
... (Single Gate Model LA400PKGUL) LiftMaster LA400 Residential DC Linear Actuator (Dual Gate Model LA400PKGUL+LA400DCS) LiftMaster LA412 Solar Gate Operator System (Single Gate Model LA412PKGUL) LiftMaster LA412 Solar Gate Operator System (Single Gate Model LA412XL20W} LiftMaster LA412 Solar Gate Operator System (Dual Gate Model LA412PKGUL+LA412DCS) LiftMaster LA500 Light Commercial I Residential DC Linear Actuator (Single Gate Model LA500PKGUL) LiftMaster LA500 Light Commercial...
... (Single Gate Model LA400PKGUL) LiftMaster LA400 Residential DC Linear Actuator (Dual Gate Model LA400PKGUL+LA400DCS) LiftMaster LA412 Solar Gate Operator System (Single Gate Model LA412PKGUL) LiftMaster LA412 Solar Gate Operator System (Single Gate Model LA412XL20W} LiftMaster LA412 Solar Gate Operator System (Dual Gate Model LA412PKGUL+LA412DCS) LiftMaster LA500 Light Commercial I Residential DC Linear Actuator (Single Gate Model LA500PKGUL) LiftMaster LA500 Light Commercial...