LA400 Manual
Page 24
... box be connected to desired setting. NOTE: The gate with the longer travel span (opening) must be set as this gate. If a solenoid lock is the primary gate. BIPART DELAY BI-PART DELAY Z9 Z8 OFF MAX OUTSIDE PROPERTY Primary Gate - Connect to the Gate 1 connector. Primary... Gate OUTSIDE PROPERTY 23 WIRING » SET THE BIPART DELAY (MODEL LA400-S ONLY) SET THE BIPART DELAY (MODEL LA400-S ONLY) In some dual gate installations, one gate or if using a solenoid lock, for the control box, then mount the control box on the opposite side, but connect...
... box be connected to desired setting. NOTE: The gate with the longer travel span (opening) must be set as this gate. If a solenoid lock is the primary gate. BIPART DELAY BI-PART DELAY Z9 Z8 OFF MAX OUTSIDE PROPERTY Primary Gate - Connect to the Gate 1 connector. Primary... Gate OUTSIDE PROPERTY 23 WIRING » SET THE BIPART DELAY (MODEL LA400-S ONLY) SET THE BIPART DELAY (MODEL LA400-S ONLY) In some dual gate installations, one gate or if using a solenoid lock, for the control box, then mount the control box on the opposite side, but connect...
LA400 Manual
Page 39
Solenoid Lock (optional) MAGLOCK NO C NC ACCESSORY POWER 24V Maglock (optional) MAGLOCK NO C NC (not provided) Flashing Strobe (optional) Siren (optional) Fault Alarm Provides 24 Vdc. P2 ...-LN4 CPS-RN4 MODEL G65MG0204 G65MG0205 G65MGR205 G65MGS205 PHOTOELECTRIC CONTROLS DESCRIPTION Emitter, receiver and mounting brackets - 30 feet (9 m) Ranges VOLTAGE +24 Vdc Emitter with the LA400 to control box depending on wire gauge and distance - 300 mA accessory power, 75 mA switched accessory power. PIN:G65ME120C5) Miller MGR20 2-wire electric edge...
Solenoid Lock (optional) MAGLOCK NO C NC ACCESSORY POWER 24V Maglock (optional) MAGLOCK NO C NC (not provided) Flashing Strobe (optional) Siren (optional) Fault Alarm Provides 24 Vdc. P2 ...-LN4 CPS-RN4 MODEL G65MG0204 G65MG0205 G65MGR205 G65MGS205 PHOTOELECTRIC CONTROLS DESCRIPTION Emitter, receiver and mounting brackets - 30 feet (9 m) Ranges VOLTAGE +24 Vdc Emitter with the LA400 to control box depending on wire gauge and distance - 300 mA accessory power, 75 mA switched accessory power. PIN:G65ME120C5) Miller MGR20 2-wire electric edge...
LA400 Manual
Page 43
... CLOSE PHOTO EYE 6. 24VDC ACCESSORY OUTPUT 7. MASTER GATE JOG 20. LIMIT SET 21. ANTENNA INPUT 2. TRANSFORMER INPUT 10. MAGLOCK/SOLENOID OUTPUT 14. DIP SWITCH, S1 18. SECOND GATE JOG 22. BIPART DELAY SET 25. TROUBLESHOOTING » WIRING DIAGRAM + DIAGNOSTIC CODES... Failed RAM Check Failed EEPROM Check Failed - LEARN XMITTER 19. SECOND - SBC (SINGLE BUTTON CONTROL) 23. BATTERY INPUT #1 16. WIRING DIAGRAM Solenoid Lock (optional) MAGLOCK NO C NC Maglock (optional) MAGLOCK NO C NC (not provided) Flashing Strobe (optional) (not provided) 1. OPEN PHOTO EYE...
... CLOSE PHOTO EYE 6. 24VDC ACCESSORY OUTPUT 7. MASTER GATE JOG 20. LIMIT SET 21. ANTENNA INPUT 2. TRANSFORMER INPUT 10. MAGLOCK/SOLENOID OUTPUT 14. DIP SWITCH, S1 18. SECOND GATE JOG 22. BIPART DELAY SET 25. TROUBLESHOOTING » WIRING DIAGRAM + DIAGNOSTIC CODES... Failed RAM Check Failed EEPROM Check Failed - LEARN XMITTER 19. SECOND - SBC (SINGLE BUTTON CONTROL) 23. BATTERY INPUT #1 16. WIRING DIAGRAM Solenoid Lock (optional) MAGLOCK NO C NC Maglock (optional) MAGLOCK NO C NC (not provided) Flashing Strobe (optional) (not provided) 1. OPEN PHOTO EYE...
LA400 Manual
Page 47
...operator to push the gate open. Can be welded onto gate or post. 12 Vdc operation, solenoid-activated release. Requires separate power supply (Model ARMP5). The model LA400 requires two batteries. Can be released in a small relay type housing so it is easy to....7 m) 24 V. Commercial Protector System® (Direct Connect): Maximum range is lost. Recommended for the operator. To order visit www.liftmaster.com 46 Gate Solenoid Lock: Heavy all steel construction. SECURITY✚® Keyless Entry : Enables homeowner to integrate with SECURITY✚® : With key ring ...
...operator to push the gate open. Can be welded onto gate or post. 12 Vdc operation, solenoid-activated release. Requires separate power supply (Model ARMP5). The model LA400 requires two batteries. Can be released in a small relay type housing so it is easy to....7 m) 24 V. Commercial Protector System® (Direct Connect): Maximum range is lost. Recommended for the operator. To order visit www.liftmaster.com 46 Gate Solenoid Lock: Heavy all steel construction. SECURITY✚® Keyless Entry : Enables homeowner to integrate with SECURITY✚® : With key ring ...