Solar Gate Access System Daily Cycle Chart Manual
Page 1
...reach below 32°F (and above -4°F) for more information, visit dealer.liftmaster.com or contact your Sales or Customer Care Representative at all other times. ...Gate installation (800lbs 12ft Gate) CONFIGURATION ZONE 1 ZONE 2 ZONE 3 (6 Hrs (4 Hrs (2 Hrs sunlight/day) sunlight/day) sunlight/day) 40W SOLAR PANEL ✔ NOTE: 40W would be located in an open... (optional) 7AH Batteries (standard) 33AH Batteries (optional) CSW24V & CSL24V Solar Gate Access System Daily Cycle Chart The CSW24V and CSL24V Solar Gate Access System Solar panel(s) must be two 20W panels in series. ...
...reach below 32°F (and above -4°F) for more information, visit dealer.liftmaster.com or contact your Sales or Customer Care Representative at all other times. ...Gate installation (800lbs 12ft Gate) CONFIGURATION ZONE 1 ZONE 2 ZONE 3 (6 Hrs (4 Hrs (2 Hrs sunlight/day) sunlight/day) sunlight/day) 40W SOLAR PANEL ✔ NOTE: 40W would be located in an open... (optional) 7AH Batteries (standard) 33AH Batteries (optional) CSW24V & CSL24V Solar Gate Access System Daily Cycle Chart The CSW24V and CSL24V Solar Gate Access System Solar panel(s) must be two 20W panels in series. ...
CSL24V Quick Start Guide Manual
Page 2
... LIMIT 4 Press and hold one of the MOVE GATE button to move the gate to the open gate and a rigid structure. GATE 5 SET OPEN SET CLOSE INPUT POWER STATUS: OFF 5 Press and release the SET CLOSE or SET OPEN button depending on which limit is the same for either...Wire Jumper 3 POWER WIRING This operator can withstand the forces generated during this obstruction test. 3 Run the gate in the close . When limits are set . 6 Cycle the gate open or closed position, increase the force by itself nor cause nuisance interruptions, but MUST reverse after every force setting...
... LIMIT 4 Press and hold one of the MOVE GATE button to move the gate to the open gate and a rigid structure. GATE 5 SET OPEN SET CLOSE INPUT POWER STATUS: OFF 5 Press and release the SET CLOSE or SET OPEN button depending on which limit is the same for either...Wire Jumper 3 POWER WIRING This operator can withstand the forces generated during this obstruction test. 3 Run the gate in the close . When limits are set . 6 Cycle the gate open or closed position, increase the force by itself nor cause nuisance interruptions, but MUST reverse after every force setting...
CSL24V User Manual
Page 2
The reset switch will disable the gate in the present position and will stop a moving gate during a normal open/close cycle, like a stop button. MODEL CSL24V SLIDE GATE OPERATOR Press the reset switch to RESET/ DISCONNECT to allow the gate to be opened and closed manually. To resume normal ...to the NORMAL OPERATION position. RESET/DISCONNECT NORMAL OPERATION MODEL CSW24V SWING GATE Manual Disconnect OPERATOR Handle Press the reset switch to NORMAL OPERATION. Thank you for two minutes. Think LiftMaster for years of safe and reliable service. OPERATION RESET SWITCH/MANUAL ...
The reset switch will disable the gate in the present position and will stop a moving gate during a normal open/close cycle, like a stop button. MODEL CSL24V SLIDE GATE OPERATOR Press the reset switch to RESET/ DISCONNECT to allow the gate to be opened and closed manually. To resume normal ...to the NORMAL OPERATION position. RESET/DISCONNECT NORMAL OPERATION MODEL CSW24V SWING GATE Manual Disconnect OPERATOR Handle Press the reset switch to NORMAL OPERATION. Thank you for two minutes. Think LiftMaster for years of safe and reliable service. OPERATION RESET SWITCH/MANUAL ...
CSL24V User Manual
Page 3
... is off the alarm and reset the operator. After the operator is in the open cycle another activation of the remote control will stop and the next activation will open the gate. When the gate is given after the initial 5 minutes the operator will beep. If a command is in the ... to be reset. During the open position, activation of the remote control will close the gate. Debris is on the gate frame while the gate is moving. (Swing Only) The gate is moving freely. (Swing Only) A foreign object is on the gate's track such as follows: When gate is reset, normal functions will ...
... is off the alarm and reset the operator. After the operator is in the open cycle another activation of the remote control will stop and the next activation will open the gate. When the gate is given after the initial 5 minutes the operator will beep. If a command is in the ... to be reset. During the open position, activation of the remote control will close the gate. Debris is on the gate frame while the gate is moving. (Swing Only) The gate is moving freely. (Swing Only) A foreign object is on the gate's track such as follows: When gate is reset, normal functions will ...
CSL24V User Manual
Page 7
...Model MG1300 6 Up to three solar panels can be released in the ground and can detect a car as it approaches and will then open and locks when the gate is closed. Must be mounted onto a gate or post. Can be powered separately. Models GC824 (115 Vac) and CC824-12 (12/24 Vac/dc) MAGNETIC... to replace original batteries provided with Solar Applications. Model K75-34986-2 (battery tray for slide operator) Model 10-36183 (battery tray for swing operator) SOLENOID GATE LOCK The automatic gate lock is a solenoid-driven lock that automatically unlocks when the gate is open the gate.
...Model MG1300 6 Up to three solar panels can be released in the ground and can detect a car as it approaches and will then open and locks when the gate is closed. Must be mounted onto a gate or post. Can be powered separately. Models GC824 (115 Vac) and CC824-12 (12/24 Vac/dc) MAGNETIC... to replace original batteries provided with Solar Applications. Model K75-34986-2 (battery tray for slide operator) Model 10-36183 (battery tray for swing operator) SOLENOID GATE LOCK The automatic gate lock is a solenoid-driven lock that automatically unlocks when the gate is open the gate.